Siemens 3RT2627-1AP05 3RT2 36A 3P 400V Contactor
Siemens 3RT2626-1AP05 3RT2 29A 3P 400V Contactor
Siemens 3RT2625-1AP05 3RT2 24A 3P 400V Contactor
Siemens 3RT2617-1AP03 3RT2 18A 3P 400V Contactor
Siemens 3RT2448-1AP00 3RT2 160A 3P 690V Contactor
Siemens 3RT2446-1AP00 3RT2 140A 3P 690V Contactor
Siemens 3RT2348-1AP00 3RT2 160A 4P 400V Contactor
Siemens 3RT2346-1AP00 3RT2 140A 4P 400V Contactor
Siemens 3RT2337-1AP00 3RT2 110A 4P 400V Contactor
Siemens 3RT2336-1AP00 3RT2 60A 4P 400V Contactor
Siemens 3RT2327-1AP00 3RT2 50A 4P 400V Contactor
Siemens 3RT2326-1AP00 3RT2 40A 4P 400V Contactor
Siemens 3RT2325-1AP00 3RT2 35A 4P 400V Contactor
Siemens 3RT2317-1AP00 3RT2 22A 4P 400V Contactor
Siemens 3RT2316-1AP00 3RT2 18A 4P 400V Contactor
Siemens 3RT2047-1NB30 3RT2 110A 3P 400V Contactor
Siemens 3RT2047-1AP00 3RT2 110A 3P 400V Contactor
Siemens 3RT2046-1NB30 3RT2 95A 3P 400V Contactor
Siemens 3RT2046-1AP00 3RT2 95A 3P 400V Contactor
Siemens 3RT2045-1NB30 3RT2 80A 3P 400V Contactor
Motor control and protection equipment from ABB, Siemens and Schneider Electric covers everything between the supply and the motor shaft. The range spans contactors, overload relays, motor protection circuit breakers, starters, soft starters, variable frequency drives, servo systems and industrial motors, with rated currents from 0.1 A to 2,650 A and power up to 800 kW. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- Contactors – switching devices for motor and load circuits, mostly 3-pole
- Thermal Overload Relays – bimetal and electronic relays for motor overload protection
- Motor Protection Circuit Breakers (MPCB) – short-circuit and overload protection in one device
- Motor Starters & Motor Management – starter combinations and motor controllers such as TeSys U and SIRIUS 3RK
- Soft Starters – controlled ramp-up for 3-phase motors
- Variable Frequency Drives (VFD) – speed control with ABB ACS, Schneider Altivar and Siemens SINAMICS
- Servo Drives & Motion Control – servo motors, drives, controllers and cables
- Industrial Motors – SIMOTICS asynchronous motors
How to choose
- Motor power and rated current at the supply voltage. Size the starter or drive for the nameplate current, not just the kW value.
- Starting method: direct on line, soft start or variable speed. This decides whether you need a contactor, a soft starter or a VFD.
- Duty class, for example AC-3 for squirrel-cage motors under IEC 60947-4-1.
- Protection split: overload relay plus fuses or MCB, or a single MPCB.
- Control interface: coil voltage, fieldbus such as PROFINET, and mounting.
FAQ
What is the difference between a soft starter and a VFD?
A soft starter limits inrush current during start and stop at fixed supply frequency. A VFD changes the output frequency, so it also controls speed while running.
Do I need a contactor and an overload relay, or an MPCB?
An MPCB combines short-circuit and overload protection and works with a contactor. The separate route uses a fuse or MCB, a contactor and an overload relay. Choose by space, coordination type and rating.
Can you ship motor control products outside Turkey?
Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, and project quantities are quoted on request.