Filter

Motor Control & Protection Categories

Motor Control & Protection

Filter
Showing 1 - 1840 of 3212 items

Siemens 3RT2936-1BB00 3RT2 48V Contactor

Reference No: 3RT2936-1BB00
Catalog No: 3RT2936-1BB00
Rated Voltage (VAC): 48 V
22 pcs in stock
$16.24

Siemens 3RT2935-6A 3RT2 Contactor

Reference No: 3RT2935-6A
Catalog No: 3RT2935-6A
10 pcs in stock
$48.90

Siemens 3RT2934-5AP01 3RT2 230V Contactor

Reference No: 3RT2934-5AP01
Catalog No: 3RT2934-5AP01
Rated Voltage (VAC): 230 V
7 pcs in stock
$18.11

Siemens 3RT2926-5AP01 3RT2 230V Contactor

Reference No: 3RT2926-5AP01
Catalog No: 3RT2926-5AP01
Rated Voltage (VAC): 230 V
43 pcs in stock
$16.34

Siemens 3RT2926-5AB01 3RT2 24V Contactor

Reference No: 3RT2926-5AB01
Catalog No: 3RT2926-5AB01
Rated Voltage (VAC): 24 V
0 pcs in stock
$19.98

Siemens 3RT2926-1JL00 3RT2 240V Contactor

Reference No: 3RT2926-1JL00
Catalog No: 3RT2926-1JL00
Rated Voltage (VAC): 240 V
51 pcs in stock
$12.26

Siemens 3RT2926-1ER00 3RT2 24V Contactor

Reference No: 3RT2926-1ER00
Catalog No: 3RT2926-1ER00
Rated Voltage (VAC): 24 V
11 pcs in stock
$12.31

Siemens 3RT2926-1CD00 3RT2 240V Contactor

Reference No: 3RT2926-1CD00
Catalog No: 3RT2926-1CD00
Rated Voltage (VAC): 240 V
99 pcs in stock
$16.35

Siemens 3RT2926-1BD00 3RT2 240V Contactor

Reference No: 3RT2926-1BD00
Catalog No: 3RT2926-1BD00
Rated Voltage (VAC): 240 V
85 pcs in stock
$15.04

Siemens 3RT2924-5AP01 3RT2 230V Contactor

Reference No: 3RT2924-5AP01
Catalog No: 3RT2924-5AP01
Rated Voltage (VAC): 230 V
23 pcs in stock
$13.36

Siemens 3RT2924-5AB01 3RT2 24V Contactor

Reference No: 3RT2924-5AB01
Catalog No: 3RT2924-5AB01
Rated Voltage (VAC): 24 V
0 pcs in stock
$16.33

Siemens 3RT2916-1JL00 3RT2 240V Contactor

Reference No: 3RT2916-1JL00
Catalog No: 3RT2916-1JL00
Rated Voltage (VAC): 240 V
102 pcs in stock
$12.71

Siemens 3RT2916-1DG00 3RT2 250V Contactor

Reference No: 3RT2916-1DG00
Catalog No: 3RT2916-1DG00
Rated Voltage (VAC): 250 V
277 pcs in stock
$15.32

Siemens 3RT2916-1CD00 3RT2 240V Contactor

Reference No: 3RT2916-1CD00
Catalog No: 3RT2916-1CD00
Rated Voltage (VAC): 240 V
156 pcs in stock
$14.54

Siemens 3RT2916-1BD00 3RT2 240V Contactor

Reference No: 3RT2916-1BD00
Catalog No: 3RT2916-1BD00
Rated Voltage (VAC): 240 V
148 pcs in stock
$14.54

Siemens 3RT2916-1BB00 3RT2 48V Contactor

Reference No: 3RT2916-1BB00
Catalog No: 3RT2916-1BB00
Rated Voltage (VAC): 48 V
782 pcs in stock
$14.54

Siemens 3RT2646-1AP03 3RT2 144A 3P 400V Contactor

Reference No: 3RT2646-1AP03
Catalog No: 3RT2646-1AP03
Rated Current (A): 144
Rated Voltage (VAC): 400 V
Number of Poles: 3P
96 pcs in stock
$528.89

Siemens 3RT2637-1AP03 3RT2 108A 3P 400V Contactor

Reference No: 3RT2637-1AP03
Catalog No: 3RT2637-1AP03
Rated Current (A): 108
Rated Voltage (VAC): 400 V
Number of Poles: 3P
336 pcs in stock
$374.66

Siemens 3RT2636-1AP03 3RT2 72.2A 3P 400V Contactor

Reference No: 3RT2636-1AP03
Catalog No: 3RT2636-1AP03
Rated Current (A): 72.2
Rated Voltage (VAC): 400 V
Number of Poles: 3P
413 pcs in stock
$279.16

Siemens 3RT2628-1AP05 3RT2 47.6A 3P 400V Contactor

Reference No: 3RT2628-1AP05
Catalog No: 3RT2628-1AP05
Rated Current (A): 47.6
Rated Voltage (VAC): 400 V
Number of Poles: 3P
197 pcs in stock
$183.67

Motor control and protection equipment from ABB, Siemens and Schneider Electric covers everything between the supply and the motor shaft. The range spans contactors, overload relays, motor protection circuit breakers, starters, soft starters, variable frequency drives, servo systems and industrial motors, with rated currents from 0.1 A to 2,650 A and power up to 800 kW. Stoklink ships worldwide from Turkey and quotes project volumes on request.

What's in this range

How to choose

  • Motor power and rated current at the supply voltage. Size the starter or drive for the nameplate current, not just the kW value.
  • Starting method: direct on line, soft start or variable speed. This decides whether you need a contactor, a soft starter or a VFD.
  • Duty class, for example AC-3 for squirrel-cage motors under IEC 60947-4-1.
  • Protection split: overload relay plus fuses or MCB, or a single MPCB.
  • Control interface: coil voltage, fieldbus such as PROFINET, and mounting.

FAQ

What is the difference between a soft starter and a VFD?

A soft starter limits inrush current during start and stop at fixed supply frequency. A VFD changes the output frequency, so it also controls speed while running.

Do I need a contactor and an overload relay, or an MPCB?

An MPCB combines short-circuit and overload protection and works with a contactor. The separate route uses a fuse or MCB, a contactor and an overload relay. Choose by space, coordination type and rating.

Can you ship motor control products outside Turkey?

Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, and project quantities are quoted on request.