- Home
- All Collections
- Motor Control & Protection
Motor Control & Protection
Motor Control & Protection Categories
Motor Control & Protection
Schneider Electric ATS480C66Y Altivar ATS480 660 A 208-690 V 355 kW Soft Starter
Schneider Electric ATS480C59Y Altivar ATS480 590 A 208-690 V 315 kW Soft Starter
Schneider Electric ATS480C48Y Altivar ATS480 480 A 208-690 V 250 kW Soft Starter
Schneider Electric ATS480C41Y Altivar ATS480 410 A 208-690 V 220 kW Soft Starter
Schneider Electric ATS480C32Y Altivar ATS480 320 A 208-690 V 160 kW Soft Starter
Schneider Electric ATS480C25Y Altivar ATS480 250 A 208-690 V 132 kW Soft Starter
Schneider Electric ATS480C21Y Altivar ATS480 210 A 208-690 V 110 kW Soft Starter
Schneider Electric ATS480C17Y Altivar ATS480 170 A 208-690 V 90 kW Soft Starter
Schneider Electric ATS480C14Y Altivar ATS480 140 A 208-690 V 75 kW Soft Starter
Schneider Electric ATS480C11Y Altivar ATS480 110 A 208-690 V 55 kW Soft Starter
ATS22D88Q, Altistart 22 Series Soft Starter, 45 kW, 88 A, 230 to 440V AC
ATS22D75S6U, Altistart 22 Series Soft Starter, 37 kW, 75 A, 230 to 600V AC
ATS22D75S6, Altistart 22 Series Soft Starter, 37 kW, 75 A, 230 to 600V AC
ATS22D75Q, Altistart 22 Series Soft Starter, 37 kW, 75 A, 230 to 440V AC
ATS22D62S6, Altistart 22 Series Soft Starter, 30 kW, 62 A, 230 to 600V AC
ATS22D62Q, Altistart 22 Series Soft Starter, 30 kW, 62 A, 230 to 440V AC
ATS22D47S6, Altistart 22 Series Soft Starter, 22 kW, 47 A, 230 to 600V AC
ATS22D47Q, Altistart 22 Series Soft Starter, 22 kW, 47 A, 230 to 440V AC
ATS22D32S6, Altistart 22 Series Soft Starter, 15 kW, 32 A, 230 to 600V AC
ATS22D32Q, Altistart 22 Series Soft Starter, 15 kW, 32 A, 230 to 440V AC
Motor control and protection equipment from ABB, Siemens and Schneider Electric covers everything between the supply and the motor shaft. The range spans contactors, overload relays, motor protection circuit breakers, starters, soft starters, variable frequency drives, servo systems and industrial motors, with rated currents from 0.1 A to 2,650 A and power up to 800 kW. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- Contactors – switching devices for motor and load circuits, mostly 3-pole
- Thermal Overload Relays – bimetal and electronic relays for motor overload protection
- Motor Protection Circuit Breakers (MPCB) – short-circuit and overload protection in one device
- Motor Starters & Motor Management – starter combinations and motor controllers such as TeSys U and SIRIUS 3RK
- Soft Starters – controlled ramp-up for 3-phase motors
- Variable Frequency Drives (VFD) – speed control with ABB ACS, Schneider Altivar and Siemens SINAMICS
- Servo Drives & Motion Control – servo motors, drives, controllers and cables
- Industrial Motors – SIMOTICS asynchronous motors
How to choose
- Motor power and rated current at the supply voltage. Size the starter or drive for the nameplate current, not just the kW value.
- Starting method: direct on line, soft start or variable speed. This decides whether you need a contactor, a soft starter or a VFD.
- Duty class, for example AC-3 for squirrel-cage motors under IEC 60947-4-1.
- Protection split: overload relay plus fuses or MCB, or a single MPCB.
- Control interface: coil voltage, fieldbus such as PROFINET, and mounting.
FAQ
What is the difference between a soft starter and a VFD?
A soft starter limits inrush current during start and stop at fixed supply frequency. A VFD changes the output frequency, so it also controls speed while running.
Do I need a contactor and an overload relay, or an MPCB?
An MPCB combines short-circuit and overload protection and works with a contactor. The separate route uses a fuse or MCB, a contactor and an overload relay. Choose by space, coordination type and rating.
Can you ship motor control products outside Turkey?
Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, and project quantities are quoted on request.