- Home
- All Collections
- Molded Case Circuit Breakers (MCCB)
Molded Case Circuit Breakers (MCCB)
ABB 1SDA066730R1 A1N 125 TMF 90-900 3p F F 90A 3-Pole Fixed Moulded Case Circuit Breaker for Transformer Generator Installation Protection
ABB 1SDA066326R1 SOR-C XT1..XT4 F/P 380-440 Vac Shunt Opening Release
Siemens 3VA1580-6EF32-0AA0 3VA1 3P 800A 70kA 415V TM240 LI Molded Case Circuit Breaker
Siemens 3VA2110-6HL32-0AA0 3VA2 3P 100A 85kA 415V ETU320 LI Molded Case Circuit Breaker
Siemens 3VA2340-5HL32-0AA0 3VA2 3P 400A 55kA 415V ETU320 LI Molded Case Circuit Breaker
ABB 1SDA066428R1 AUX-C 3Q L 250Vac/dc XT3 Auxiliary Contact Accessory for Circuit Breaker
ABB 1SDA067457R1 XT1H 160 TMD 50-500 4p F F 50A 4-Pole 70kA Molded Case Circuit Breaker
Schneider Electric LV516303 CVS160B EasyPact CVS 160A 3-Pole Moulded Case Circuit Breaker
ABB 1SDA066575R1 A3S 630 ELT-LI In=630 4p F F 630A 4-Pole Fixed Molded Case Circuit Breaker
ABB 1SDA067460R1 XT1H 160 TMD 100-1000 4p F F 100A 4-Pole 70kA Fixed Molded Case Circuit Breaker
ABB 1SDA067421R1 XT1N 160 TMD 50-500 4p F F 4-Pole 50A Fixed Moulded Case Circuit Breaker
ABB 1SDA054874R1 SOR-C T4-T5-T6 380...440 Vac Shunt Opening Release Accessory for SACE Tmax T4 T5 T6 Circuit Breakers
Siemens 3VA1463-4EF42-0AA0 3VA1 4P 630A 36kA 415V TM240 LI Molded Case Circuit Breaker
Siemens 3VM1050-4ED32-0AA0 3VM1 3P 50A 36kA 415V TM210 LI Molded Case Circuit Breaker
ABB 1SDA067463R1 XT1H 160 TMD 125-1250 4p F F InN=100% 125A 4P 70kA Molded Case Circuit Breaker
ABB 1SDA063026R1 T7H 1600 PR231/P LS/I In=1600A 3p F F 1600A 3-Pole Fixed Power Circuit-Breaker
ABB 1SDA060278R1 T6S 800 PR221DS-LS/I In=800 3p F F 800A 3-Pole Fixed Power Circuit-Breaker
ABB 1SDA105012R1 PB 200mm 4pcs XT6 3p KIT PA.DI.PH.HI Kit Partitions Divider Phase High for Three-Pole
ABB 1SDA068764R1 A1N 125 TMF 32-400 4p F F 32A 4-Pole 36kA Moulded Case Circuit Breaker
Siemens 3VA1140-4EE36-0AA0 3VA1 3P 40A 36kA 415V TM220 LI Molded Case Circuit Breaker
Molded case circuit breakers (MCCB) from ABB, Schneider Electric and Siemens protect feeders, motors and distribution boards from about 10 A up to 1600 A. The range covers 3-pole and 4-pole breakers with fixed and adjustable trip units, with more than 1,800 products including accessories. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- ABB Tmax XT MCCBs – XT1 to XT7 frames with thermal-magnetic and Ekip electronic trip units.
- ABB Formula A MCCBs – A1 to A3 frames for general distribution.
- Schneider ComPacT NSX MCCBs – frames from 100 A to 630 A.
- Schneider ComPacT NS MCCBs – breakers from 630 A to 1600 A.
- Schneider GoPact MCCBs – compact breakers up to 800 A.
- Schneider EasyPact CVS MCCBs – CVS100 to CVS630 frames.
- Siemens SENTRON 3VA MCCBs – 3VA1 and 3VA2 breakers up to 1250 A.
- Siemens SENTRON 3VM MCCBs – 3VM1 breakers up to 630 A.
- MCCB Accessories, Releases & Trip Units – releases and trip units.
How to choose
- Frame size and rated current, with the trip unit set to the load current.
- Rated breaking capacity (Icu and Ics) at the system voltage, above the prospective short-circuit current.
- Trip unit: thermal-magnetic for simple feeders, electronic (LSI or LSIG) where selectivity is needed.
- Poles: 3P or 4P according to the neutral arrangement. Standard: IEC 60947-2.
FAQ
What is the difference between an MCCB and an ACB?
An MCCB is a compact molded-case breaker, typically used from tens of amperes to 1600 A. An ACB is a larger, often draw-out breaker for main incomers from 630 A upward.
What do Icu and Ics mean on an MCCB?
Icu is the ultimate breaking capacity. Ics is the service breaking capacity, the share of Icu after which the breaker stays fit for service.
Do you export MCCBs and their accessories?
Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so request a quote with your part numbers and quantities.