Siemens 3VA2716-5AB13-0AA0 3VA2 4P 1600A 55kA 415V ETU320 LI Molded Case Circuit Breaker

Reference No: 3VA2716-5AB13-0AA0
Catalog No: 3VA2716-5AB13-0AA0
Rated Current (A): 1600
Breaking Capacity (kA): 55 kA @415V AC (Icu, class M)
Rated Voltage (VAC): 690 V AC
Number of Poles: 4P
1 pcs in stock
$5,812.49

Siemens 3VM1116-3ED42-0AA0 3VM1 4P 160A 25kA 415V TM210 LI Molded Case Circuit Breaker

Reference No: 3VM1116-3ED42-0AA0
Catalog No: 3VM1116-3ED42-0AA0
Rated Current (A): 160
Breaking Capacity (kA): 25 kA @415V AC (Icu, class N)
Rated Voltage (VAC): 500 V AC
Number of Poles: 4P
6 pcs in stock
$232.50

ABB 1SDA066753R1 A1C 125 TMF 80-800 4p F F 4-Pole 80A Fixed Moulded Case Circuit Breaker

Reference No: 1SDA066753R1
Catalog No: A1C 125 TMF 80-800 4p F F
Rated Current (A): 80
Breaking Capacity (kA): (400 V AC) 25 kA
Number of Poles: 4P
139 pcs in stock
$99.96

Schneider Electric G20F3A50 GoPact MCCB 200 3P 50A 36kA 415V Molded Case Circuit Breaker

Reference No: G20F3A50
Rated Current (A): 50
Rated Voltage (VAC): 415 V AC
Number of Poles: 3P
18 pcs in stock
$105.89

ABB 1SDA062914R1 T7H 1250 PR231/P LS/I In=1250A 3p F F M 1250A 3-Pole Fixed Molded Case Circuit Breaker

Reference No: 1SDA062914R1
Catalog No: T7H 1250 PR231/P LS/I In=1250A 3p F F M
Rated Current (A): 1250
Breaking Capacity (kA): (400 V AC) 70 kA
Number of Poles: 3P
0 pcs in stock
$4,083.88

ABB 1SDA062762R1 T7S 1000 PR231/P LS/I In=1000A 4p F F M 1000A 4P Fixed Power Circuit Breaker

Reference No: 1SDA062762R1
Catalog No: T7S 1000 PR231/P LS/I In=1000A 4p F F M
Rated Current (A): 1000
Breaking Capacity (kA): (400 V AC) 50 kA
Number of Poles: 4P
0 pcs in stock
$5,425.79

Siemens 3VA1110-6EF36-0AA0 3VA1 3P 100A 70kA 415V TM240 LI Molded Case Circuit Breaker

Reference No: 3VA1110-6EF36-0AA0
Catalog No: 3VA1110-6EF36-0AA0
Rated Current (A): 100
Breaking Capacity (kA): 70 kA @415V AC (Icu, class H)
Rated Voltage (VAC): 690 V AC
Number of Poles: 3P
0 pcs in stock
$312.40

Siemens 3VA1510-5EF42-0AA0 3VA1 4P 1000A 55kA 415V TM240 LI Molded Case Circuit Breaker

Reference No: 3VA1510-5EF42-0AA0
Catalog No: 3VA1510-5EF42-0AA0
Rated Current (A): 1000
Breaking Capacity (kA): 55 kA @415V AC (Icu, class M)
Rated Voltage (VAC): 690 V AC
Number of Poles: 4P
8 pcs in stock
$2,978.40

Siemens 3VA2110-5HL32-0AA0 3VA2 3P 100A 55kA 415V ETU320 LI Molded Case Circuit Breaker

Reference No: 3VA2110-5HL32-0AA0
Catalog No: 3VA2110-5HL32-0AA0
Rated Current (A): 100
Breaking Capacity (kA): 55 kA @415V AC (Icu, class M)
Rated Voltage (VAC): 690 V AC
Number of Poles: 3P
8 pcs in stock
$319.63

Siemens 3VM1196-3EE32-0AA0 3VM1 3P 16A 25kA 415V TM220 LI Molded Case Circuit Breaker

Reference No: 3VM1196-3EE32-0AA0
Catalog No: 3VM1196-3EE32-0AA0
Rated Current (A): 16
Breaking Capacity (kA): 25 kA @415V AC (Icu, class N)
Rated Voltage (VAC): 500 V AC
Number of Poles: 3P
12 pcs in stock
$143.32

ABB 1SDA066571R1 A3S 400 TMF 400-4000 4p F F InN=100%In 4P 400A Fixed Power Circuit-Breaker

Reference No: 1SDA066571R1
Catalog No: A3S 400 TMF 400-4000 4p F F InN=100%In
Rated Current (A): 400
Breaking Capacity (kA): (400 V AC) 50 kA
Number of Poles: 4P
0 pcs in stock
$416.08

ABB 1SDA068362R1 XT4H 250 TMA 200-2000 4p F F InN=100% 200A 4-Pole Fixed Moulded Case Circuit Breaker

Reference No: 1SDA068362R1
Catalog No: XT4H 250 TMA 200-2000 4p F F InN=100%
Rated Current (A): 200
Breaking Capacity (kA): (400 V AC) 70 kA
Number of Poles: 4P
7 pcs in stock
$502.12

ABB 1SDA060236R1 T6S 630 PR221DS-LS/I In=630 3p F F 630A 3-Pole Fixed Molded Case Circuit Breaker

Reference No: 1SDA060236R1
Catalog No: T6S 630 PR221DS-LS/I In=630 3p F F
Rated Current (A): 630
Breaking Capacity (kA): (400 V AC) 50 kA
Number of Poles: 3P
0 pcs in stock
$1,721.27

ABB 1SDA104804R1 AUX-C 1S51 250V AC/dC XT6 W Tmax XT Series Auxiliary Contact Block

Reference No: 1SDA104804R1
Catalog No: AUX-C 1S51 250V AC/dC XT6 W
Rated Voltage (VAC): 250 V AC/DC
1 pcs in stock
$30.05

ABB 1SDA101712R1 XT7H M 1250 Ekip Dip LS/I In1250A 4p F F 4-Pole 1250A 70kA Fixed Moulded Case Circuit Breaker

Reference No: 1SDA101712R1
Catalog No: XT7H M 1250 Ekip Dip LS/I In1250A 4p F F
Rated Current (A): 1250
Breaking Capacity (kA): (400 V AC) 70 kA
Number of Poles: 4P
2 pcs in stock
$3,417.85

ABB 1SDA060268R1 T6N 800 PR221DS-LS/I In=800 3p F F 800A 3-Pole Fixed Power Circuit Breaker

Reference No: 1SDA060268R1
Catalog No: T6N 800 PR221DS-LS/I In=800 3p F F
Rated Current (A): 800
Breaking Capacity (kA): (400 V AC) 36 kA
Number of Poles: 3P
0 pcs in stock
$2,137.21

Siemens 3VA1225-4EF32-0AA0 SENTRON 3VA12 250A 36kA 3P Thermal Magnetic Molded Case Circuit Breaker

Reference No: 3VA1225-4EF32-0AA0
Catalog No: 3VA1225-4EF32-0AA0
Rated Current (A): 250
Breaking Capacity (kA): 36 kA
Rated Voltage (VAC): 415 V
Number of Poles: 3P
58 pcs in stock
$360.20

Siemens 3VA1112-4EF36-0AA0 3VA1 3P 125A 36kA 415V TM240 LI Molded Case Circuit Breaker

Reference No: 3VA1112-4EF36-0AA0
Catalog No: 3VA1112-4EF36-0AA0
Rated Current (A): 125
Breaking Capacity (kA): 36 kA @415V AC (Icu, class S)
Rated Voltage (VAC): 690 V AC
Number of Poles: 3P
3 pcs in stock
$239.72

Siemens 3VA1112-5EF36-0AA0 3VA1 3P 125A 55kA 415V TM240 LI Molded Case Circuit Breaker

Reference No: 3VA1112-5EF36-0AA0
Catalog No: 3VA1112-5EF36-0AA0
Rated Current (A): 125
Breaking Capacity (kA): 55 kA @415V AC (Icu, class M)
Rated Voltage (VAC): 690 V AC
Number of Poles: 3P
24 pcs in stock
$299.33

Siemens 3VA1140-5EE36-0AA0 3VA1 3P 40A 55kA 415V TM220 LI Molded Case Circuit Breaker

Reference No: 3VA1140-5EE36-0AA0
Catalog No: 3VA1140-5EE36-0AA0
Rated Current (A): 40
Breaking Capacity (kA): 55 kA @415V AC (Icu, class M)
Rated Voltage (VAC): 690 V AC
Number of Poles: 3P
10 pcs in stock
$208.22

Molded case circuit breakers (MCCB) from ABB, Schneider Electric and Siemens protect feeders, motors and distribution boards from about 10 A up to 1600 A. The range covers 3-pole and 4-pole breakers with fixed and adjustable trip units, with more than 1,800 products including accessories. Stoklink ships worldwide from Turkey and quotes project volumes on request.

What's in this range

How to choose

  • Frame size and rated current, with the trip unit set to the load current.
  • Rated breaking capacity (Icu and Ics) at the system voltage, above the prospective short-circuit current.
  • Trip unit: thermal-magnetic for simple feeders, electronic (LSI or LSIG) where selectivity is needed.
  • Poles: 3P or 4P according to the neutral arrangement. Standard: IEC 60947-2.

FAQ

What is the difference between an MCCB and an ACB?

An MCCB is a compact molded-case breaker, typically used from tens of amperes to 1600 A. An ACB is a larger, often draw-out breaker for main incomers from 630 A upward.

What do Icu and Ics mean on an MCCB?

Icu is the ultimate breaking capacity. Ics is the service breaking capacity, the share of Icu after which the breaker stays fit for service.

Do you export MCCBs and their accessories?

Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so request a quote with your part numbers and quantities.