Showing 1 - 520 of 1818 items

Siemens 3VA1180-5EF36-0AA0 3VA1 3P 80A 55kA 415V TM240 LI Molded Case Circuit Breaker

Reference No: 3VA1180-5EF36-0AA0
Catalog No: 3VA1180-5EF36-0AA0
Rated Current (A): 80
Breaking Capacity (kA): 55 kA @415V AC (Icu, class M)
Rated Voltage (VAC): 690 V AC
Number of Poles: 3P
11 pcs in stock
$218.07

Siemens 3VA2225-6HL32-0AA0 3VA2 3P 250A 85kA 415V ETU320 LI Molded Case Circuit Breaker

Reference No: 3VA2225-6HL32-0AA0
Catalog No: 3VA2225-6HL32-0AA0
Rated Current (A): 250
Breaking Capacity (kA): 85 kA @415V AC (Icu, class H)
Rated Voltage (VAC): 690 V AC
Number of Poles: 3P
0 pcs in stock
$943.58

Siemens 3VA2580-5HL42-0AA0 3VA2 4P 800A 55kA 415V ETU320 LI Molded Case Circuit Breaker

Reference No: 3VA2580-5HL42-0AA0
Catalog No: 3VA2580-5HL42-0AA0
Rated Current (A): 800
Breaking Capacity (kA): 55 kA @415V AC (Icu, class M)
Rated Voltage (VAC): 690 V AC
Number of Poles: 4P
0 pcs in stock
$2,974.06

Schneider Electric LV429434 MT250 Motor Mechanism Module Compact NSX Series

Reference No: LV429434
39 pcs in stock
$390.91

Siemens 3VA1140-4EF36-0AA0 3VA1 3P 40A 36kA 415V TM240 LI Molded Case Circuit Breaker

Reference No: 3VA1140-4EF36-0AA0
Catalog No: 3VA1140-4EF36-0AA0
Rated Current (A): 40
Breaking Capacity (kA): 36 kA @415V AC (Icu, class S)
Rated Voltage (VAC): 690 V AC
Number of Poles: 3P
8 pcs in stock
$181.70

Siemens 3VA1332-5MH32-0AA0 3VA1 3P 320A 55kA 415V TM120M I Molded Case Circuit Breaker

Reference No: 3VA1332-5MH32-0AA0
Catalog No: 3VA1332-5MH32-0AA0
Rated Current (A): 320
Breaking Capacity (kA): 55 kA @415V AC (Icu, class M)
Rated Voltage (VAC): 690 V AC
Number of Poles: 3P
3 pcs in stock
$683.82

Siemens 3VA2340-4HL32-0AA0 3VA2 3P 400A 36kA 415V ETU320 LI Molded Case Circuit Breaker

Reference No: 3VA2340-4HL32-0AA0
Catalog No: 3VA2340-4HL32-0AA0
Rated Current (A): 400
Breaking Capacity (kA): 36 kA @415V AC (Icu, class S)
Rated Voltage (VAC): 690 V AC
Number of Poles: 3P
0 pcs in stock
$1,167.86

Siemens 3VM1112-4ED32-0AA0 3VM1 3P 125A 36kA 415V TM210 LI Molded Case Circuit Breaker

Reference No: 3VM1112-4ED32-0AA0
Catalog No: 3VM1112-4ED32-0AA0
Rated Current (A): 125
Breaking Capacity (kA): 36 kA @415V AC (Icu, class S)
Rated Voltage (VAC): 500 V AC
Number of Poles: 3P
28 pcs in stock
$182.19

Siemens 3VM1150-3EE32-0AA0 3VM1 3P 50A 25kA 415V TM220 LI Molded Case Circuit Breaker

Reference No: 3VM1150-3EE32-0AA0
Catalog No: 3VM1150-3EE32-0AA0
Rated Current (A): 50
Breaking Capacity (kA): 25 kA @415V AC (Icu, class N)
Rated Voltage (VAC): 500 V AC
Number of Poles: 3P
47 pcs in stock
$117.27

ABB 1SDA066696R1 A1N 125 TMF 125-1250 1p F F 125A 1-Pole Fixed Moulded Case Circuit Breaker

Reference No: 1SDA066696R1
Catalog No: A1N 125 TMF 125-1250 1p F F
Rated Current (A): 125
Breaking Capacity (kA): (240 V AC) 25 kA
Number of Poles: 1P
32 pcs in stock
$63.46

ABB 1SDA067576R1 XT2S 160 TMA 50-500 4p F F 50A 4-Pole 50kA Fixed Moulded Case Circuit Breaker

Reference No: 1SDA067576R1
Catalog No: XT2S 160 TMA 50-500 4p F F
Rated Current (A): 50
Breaking Capacity (kA): (400 V AC) 50 kA
Number of Poles: 4P
1 pcs in stock
$196.28

ABB 1SDA100763R1 XT6H 800 Ekip Dip LS/I In=800 3p F F 800A 3-Pole 70kA Fixed Moulded Case Circuit Breaker

Reference No: 1SDA100763R1
Catalog No: XT6H 800 Ekip Dip LS/I In=800 3p F F
Rated Current (A): 800
Breaking Capacity (kA): (400 V AC) 70 kA
Number of Poles: 3P
3 pcs in stock
$1,313.48

ABB 1SDA066768R1 A1N 125 TMF 125-1250 4p F F 4-Pole 125A Fixed Moulded Case Circuit Breaker for Transformer Generator Installation Protection

Reference No: 1SDA066768R1
Catalog No: A1N 125 TMF 125-1250 4p F F
Rated Current (A): 125
Breaking Capacity (kA): (400 V AC) 36 kA
Number of Poles: 4P
588 pcs in stock
$112.69

ABB 1SDA062882R1 T7S 1250 PR231/P LS/I In=1250A 3p F F M 1250A 3-Pole Fixed Power Circuit Breaker

Reference No: 1SDA062882R1
Catalog No: T7S 1250 PR231/P LS/I In=1250A 3p F F M
Rated Current (A): 1250
Breaking Capacity (kA): (400 V AC) 50 kA
Number of Poles: 3P
0 pcs in stock
$3,917.27

Schneider Electric LV563505 CVS630F EasyPact CVS 630A 3P Moulded Case Circuit Breaker

Reference No: LV563505
Rated Current (A): 630
Number of Poles: 3P
28 pcs in stock
$738.82

Schneider Electric LV510336 CVS100F 3-Pole 80A Moulded Case Circuit Breaker EasyPact CVS Series

Reference No: LV510336
Rated Current (A): 80
Number of Poles: 3P
48 pcs in stock
$124.00

ABB 1SDA068310R1 XT4S 250 TMA 200-2000 3p F F 200A 3-Pole Fixed Moulded Case Circuit Breaker

Reference No: 1SDA068310R1
Catalog No: XT4S 250 TMA 200-2000 3p F F
Rated Current (A): 200
Breaking Capacity (kA): (400 V AC) 50 kA
Number of Poles: 3P
20 pcs in stock
$243.24

Siemens 3VA1110-5EE36-0AA0 3VA1 3P 100A 55kA 415V TM220 LI Molded Case Circuit Breaker

Reference No: 3VA1110-5EE36-0AA0
Catalog No: 3VA1110-5EE36-0AA0
Rated Current (A): 100
Breaking Capacity (kA): 55 kA @415V AC (Icu, class M)
Rated Voltage (VAC): 690 V AC
Number of Poles: 3P
43 pcs in stock
$208.22

Siemens 3VA1180-5EE36-0AA0 3VA1 3P 80A 55kA 415V TM220 LI Molded Case Circuit Breaker

Reference No: 3VA1180-5EE36-0AA0
Catalog No: 3VA1180-5EE36-0AA0
Rated Current (A): 80
Breaking Capacity (kA): 55 kA @415V AC (Icu, class M)
Rated Voltage (VAC): 690 V AC
Number of Poles: 3P
34 pcs in stock
$208.22

Siemens 3VA2580-5MN32-0AA0 3VA2 3P 800A 55kA 415V ETU350M LSI Molded Case Circuit Breaker

Reference No: 3VA2580-5MN32-0AA0
Catalog No: 3VA2580-5MN32-0AA0
Rated Current (A): 800
Breaking Capacity (kA): 55 kA @415V AC (Icu, class M)
Rated Voltage (VAC): 690 V AC
Number of Poles: 3P
0 pcs in stock
$1,868.06

Molded case circuit breakers (MCCB) from ABB, Schneider Electric and Siemens protect feeders, motors and distribution boards from about 10 A up to 1600 A. The range covers 3-pole and 4-pole breakers with fixed and adjustable trip units, with more than 1,800 products including accessories. Stoklink ships worldwide from Turkey and quotes project volumes on request.

What's in this range

How to choose

  • Frame size and rated current, with the trip unit set to the load current.
  • Rated breaking capacity (Icu and Ics) at the system voltage, above the prospective short-circuit current.
  • Trip unit: thermal-magnetic for simple feeders, electronic (LSI or LSIG) where selectivity is needed.
  • Poles: 3P or 4P according to the neutral arrangement. Standard: IEC 60947-2.

FAQ

What is the difference between an MCCB and an ACB?

An MCCB is a compact molded-case breaker, typically used from tens of amperes to 1600 A. An ACB is a larger, often draw-out breaker for main incomers from 630 A upward.

What do Icu and Ics mean on an MCCB?

Icu is the ultimate breaking capacity. Ics is the service breaking capacity, the share of Icu after which the breaker stays fit for service.

Do you export MCCBs and their accessories?

Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so request a quote with your part numbers and quantities.