- Home
- All Collections
- Molded Case Circuit Breakers (MCCB)
Molded Case Circuit Breakers (MCCB)
Siemens 3VA1180-5EF36-0AA0 3VA1 3P 80A 55kA 415V TM240 LI Molded Case Circuit Breaker
Siemens 3VA2225-6HL32-0AA0 3VA2 3P 250A 85kA 415V ETU320 LI Molded Case Circuit Breaker
Siemens 3VA2580-5HL42-0AA0 3VA2 4P 800A 55kA 415V ETU320 LI Molded Case Circuit Breaker
Schneider Electric LV429434 MT250 Motor Mechanism Module Compact NSX Series
Siemens 3VA1140-4EF36-0AA0 3VA1 3P 40A 36kA 415V TM240 LI Molded Case Circuit Breaker
Siemens 3VA1332-5MH32-0AA0 3VA1 3P 320A 55kA 415V TM120M I Molded Case Circuit Breaker
Siemens 3VA2340-4HL32-0AA0 3VA2 3P 400A 36kA 415V ETU320 LI Molded Case Circuit Breaker
Siemens 3VM1112-4ED32-0AA0 3VM1 3P 125A 36kA 415V TM210 LI Molded Case Circuit Breaker
Siemens 3VM1150-3EE32-0AA0 3VM1 3P 50A 25kA 415V TM220 LI Molded Case Circuit Breaker
ABB 1SDA066696R1 A1N 125 TMF 125-1250 1p F F 125A 1-Pole Fixed Moulded Case Circuit Breaker
ABB 1SDA067576R1 XT2S 160 TMA 50-500 4p F F 50A 4-Pole 50kA Fixed Moulded Case Circuit Breaker
ABB 1SDA100763R1 XT6H 800 Ekip Dip LS/I In=800 3p F F 800A 3-Pole 70kA Fixed Moulded Case Circuit Breaker
ABB 1SDA066768R1 A1N 125 TMF 125-1250 4p F F 4-Pole 125A Fixed Moulded Case Circuit Breaker for Transformer Generator Installation Protection
ABB 1SDA062882R1 T7S 1250 PR231/P LS/I In=1250A 3p F F M 1250A 3-Pole Fixed Power Circuit Breaker
Schneider Electric LV563505 CVS630F EasyPact CVS 630A 3P Moulded Case Circuit Breaker
Schneider Electric LV510336 CVS100F 3-Pole 80A Moulded Case Circuit Breaker EasyPact CVS Series
ABB 1SDA068310R1 XT4S 250 TMA 200-2000 3p F F 200A 3-Pole Fixed Moulded Case Circuit Breaker
Siemens 3VA1110-5EE36-0AA0 3VA1 3P 100A 55kA 415V TM220 LI Molded Case Circuit Breaker
Siemens 3VA1180-5EE36-0AA0 3VA1 3P 80A 55kA 415V TM220 LI Molded Case Circuit Breaker
Siemens 3VA2580-5MN32-0AA0 3VA2 3P 800A 55kA 415V ETU350M LSI Molded Case Circuit Breaker
Molded case circuit breakers (MCCB) from ABB, Schneider Electric and Siemens protect feeders, motors and distribution boards from about 10 A up to 1600 A. The range covers 3-pole and 4-pole breakers with fixed and adjustable trip units, with more than 1,800 products including accessories. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- ABB Tmax XT MCCBs – XT1 to XT7 frames with thermal-magnetic and Ekip electronic trip units.
- ABB Formula A MCCBs – A1 to A3 frames for general distribution.
- Schneider ComPacT NSX MCCBs – frames from 100 A to 630 A.
- Schneider ComPacT NS MCCBs – breakers from 630 A to 1600 A.
- Schneider GoPact MCCBs – compact breakers up to 800 A.
- Schneider EasyPact CVS MCCBs – CVS100 to CVS630 frames.
- Siemens SENTRON 3VA MCCBs – 3VA1 and 3VA2 breakers up to 1250 A.
- Siemens SENTRON 3VM MCCBs – 3VM1 breakers up to 630 A.
- MCCB Accessories, Releases & Trip Units – releases and trip units.
How to choose
- Frame size and rated current, with the trip unit set to the load current.
- Rated breaking capacity (Icu and Ics) at the system voltage, above the prospective short-circuit current.
- Trip unit: thermal-magnetic for simple feeders, electronic (LSI or LSIG) where selectivity is needed.
- Poles: 3P or 4P according to the neutral arrangement. Standard: IEC 60947-2.
FAQ
What is the difference between an MCCB and an ACB?
An MCCB is a compact molded-case breaker, typically used from tens of amperes to 1600 A. An ACB is a larger, often draw-out breaker for main incomers from 630 A upward.
What do Icu and Ics mean on an MCCB?
Icu is the ultimate breaking capacity. Ics is the service breaking capacity, the share of Icu after which the breaker stays fit for service.
Do you export MCCBs and their accessories?
Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so request a quote with your part numbers and quantities.