- Home
- All Collections
- Low Voltage Fuse Links (NH, BS88, Cylindrical)
Low Voltage Fuse Links (NH, BS88, Cylindrical)
ABB 1SCA022627R1120 OFAF000H40 40A 500VAC/250VDC 120kA HRC Fuselink (HRC Fuse Link)
ABB 1SCA022627R4570 OFAF1H224 224A 500VAC/250VDC 120kA HRC Fuselink (HRC Fuse Link)
ABB 1SCA022627R1470 OFAF000H80 HRC Fuse Link 80A 500VAC/250VDC 120kA
ABB 1SCA022627R4490 OFAF1H200 200A 500VAC/250VDC 120kA HRC Fuse Link
ABB 1SCA022627R1710 OFAF00H160 160A 500VAC/250VDC 120kA HRC Fuse Link Fuselink
ABB 1SCA022627R1390 OFAF000H63 HRC Fuse Link 63A 500VAC/250VDC 120kA
ABB 1SCA022627R1040 OFAF000H35 35A 500VAC/250VDC 120kA HRC Fuse Link
ABB 1SCA022627R1210 OFAF000H50 HRC Fuse Link 50A 500VAC/250VDC 120kA
ABB 1SCA022627R1630 OFAF00H125 125A 500VAC/250VDC 120kA HRC Fuse Link
ABB 1SCA022627R0740 OFAF000H20 20A 500VAC/250VDC 120kA HRC Fuse Link Fuselink
ABB 1SCA022627R0820 OFAF000H25 25A 500VAC/250VDC 120kA HRC Fuselink (HRC Fuse Link)
ABB 1SCA022627R0660 OFAF000H16 16A 500VAC/250VDC 120kA HRC Fuselink (HRC Fuse Link)
ABB 1SCA022627R0310 OFAF000H4 4A 500VAC/250VDC 120kA HRC Fuse Link Fuselink
ABB 1SCA022627R0230 OFAF000H2 HRC Fuse Link 2A 500VAC/250VDC 120kA
ABB 1SCA022627R0400 OFAF000H6 HRC Fuse Link 6A 500VAC/250VDC 120kA Fuselink
ABB 1SCA022627R0910 OFAF000H32 32A 500VAC/250VDC 120kA HRC Fuse Link
ABB 1SCA022627R0580 OFAF000H10 10A 500VAC/250VDC 120kA HRC Fuselink (HRC Fuse Link)
Low voltage fuse links from Siemens, Mersen, ABB and Schneider Electric cover NH, BS88 and cylindrical formats from 0.5 A to 1250 A. The range holds over 450 products, including Siemens 3NA3 and 3NA6, Mersen DIN CNN and BS88 links, and ABB OFAF links. Stoklink ships worldwide from Turkey on EXW terms, and quotes for project volumes are available on request.
What's in this range
- NH fuse links such as Siemens 3NA3 and 3NA6 and ABB OFAF for panel and feeder protection.
- BS88 links, including feeder pillar gU types at 415 VAC.
- Cylindrical ferrule links, for example 10x38 gG types rated 400 to 690 VAC.
- UL and DIN CNN and CNL blade fuses for North American and DIN-style equipment.
- Siemens 3NP1 and 3NW6 series fuse parts for fuse switch and holder systems.
How to choose
- Operating class: gG protects cables, aM protects motor circuits and tolerates starting current.
- Rated current and voltage: select from the load current and the line voltage, such as 400, 500 or 690 VAC.
- Size: NH00 to NH4, BS88 or 10x38 must fit the base or holder you already have.
- Breaking capacity: compare it with the prospective short-circuit current, typically stated in kA on the datasheet.
- Standard: IEC 60269 for NH and cylindrical links, BS 88 for British Standard types.
FAQ
What does gG mean on a fuse link?
gG is a full-range, general-purpose class under IEC 60269. It clears both overloads and short circuits, so it protects cables and general loads.
Are NH and BS88 fuses interchangeable?
No. The dimensions and contact systems differ, so a BS88 link does not fit an NH base. Match the link to the base or holder size.
How are orders shipped?
Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, and quotes for larger quantities are available.