- Home
- All Collections
- Contactors
Contactors
Siemens 3RT2916-1DG00 3RT2 250V Contactor
Siemens 5TT5850-0 5TT5 63A 230V Contactor
Schneider Electric LA1KN31 TeSys K 3NO+1NC Front Mount Auxiliary Contact Block
ABB 1SBL121001R2610 AS16-30-10-26 3-Pole 690V AC 230V Coil Power Contactor AC Switching
ABB 1SBH101001R2631 NS31E-26 230V 50/60Hz 4-Pole Contactor Relay
Schneider Electric LC1D80004M7 LC1D TeSys Deca 4-Pole 125A Power Contactor
Schneider Electric LADT4 LC1D TeSys Deca 3P Front Mount Time Delay Auxiliary Contact Block
Schneider Electric LC1D18M7 TeSys Deca 3-Pole 18A 10HP 480V AC Contactor
Schneider Electric GV2G454 GV3G Linergy FT 3P 63A Comb Busbar
Siemens 3RT1954-6A 3RT1 Contactor
Siemens 3RT2015-1AP02 3RT2 7A 3P 400V Contactor
Siemens 3RT2017-1AP02 3RT2 12A 3P 400V Contactor
Siemens 3RT2017-1BB41 3RT2 12A 3P 400V Contactor
Siemens 3RT2018-1BB41 3RT2 16A 3P 400V Contactor
Siemens 3RT2037-1AP00 3RT2 65A 3P 400V Contactor
Siemens 3RT2926-1BD00 3RT2 240V Contactor
Siemens 3RT2935-6A 3RT2 Contactor
Siemens 3RT2936-1CD00 3RT2 240V Contactor
Siemens 3RT2945-6A 3RT2 Contactor
Schneider Electric LC1D38E7 TeSys D 3-Pole 38A 440V Coil AC Power Contactor
Contactors from ABB, Schneider Electric and Siemens switch motor and load circuits on and off by remote control. This range covers over 900 products, from 2 A accessories to power contactors rated up to 2650 A, with motor ratings from 2.2 kW to 450 kW in 2, 3, 4 and 8 pole versions. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- Power Contactors (AC-3) – the main motor-switching contactors, including ABB AF, TeSys Deca, TeSys Giga, TeSys K, Easy TeSys and SIRIUS 3RT2 and 3RT1.
- Contactor Relays & Auxiliary Contactors – control-circuit relays with several auxiliary contacts.
- Installation Contactors – DIN-rail contactors for distribution boards, such as ABB ESB.
- Contactor Accessories (Coils, Aux Blocks) – replacement coils, auxiliary contact blocks and mounting parts.
How to choose
- Utilization category: AC-3 for squirrel-cage motor starting, AC-1 for resistive loads. The same frame carries a different current in each category.
- Rated current and motor power at your operating voltage, with margin for the duty cycle.
- Number of poles: 3P for three-phase motors, 4P for switching the neutral or four-wire loads.
- Coil voltage and type (AC, DC or AC/DC). It must match the control supply.
- Auxiliary contacts: count the NO and NC contacts the control circuit needs, and check if the contactor accepts add-on blocks.
FAQ
What is the difference between a contactor and a contactor relay?
A power contactor switches the main circuit of a motor or load. A contactor relay switches control circuits at low current, typically 10 A, and has more auxiliary contacts.
Which standard applies to contactors?
Low-voltage contactors are covered by IEC 60947-4-1. The standard defines utilization categories such as AC-1 and AC-3.
Do you ship contactors outside Turkey?
Yes. Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so send the part numbers for a quote. Project quantities are quoted on request.