- Part number
- 6GT2002-0JE50
- Model no
- RF186CI communication module RFID communication module RF186CI for PROFINET, Ethernet, EtherNet/IP, OPC/UA, 2 readers can be connected, DI/DQ interface
Siemens has announced the end of 6GT2002-0JE50
Once production ends, supply depends on remaining stock.
No replacement announced yet. Tell us the application and we will propose an alternative.
Siemens 6GT2002-0JE50 SIMATIC RFID RF186CI PROFINET Communication Module 2 Readers
SIMATIC RFID RF186CI communication module, 2 readers, PROFINET/EtherNet-IP/OPC UA, IP67.
Description
About the RF186CI communication module RFID communication module RF186CI for PROFINET, Ethernet, EtherNet/IP, OPC/UA, 2 readers can be connected, DI/DQ interface
About the RF186CI communication module RFID communication module RF186CI for PROFINET, Ethernet, EtherNet/IP, OPC/UA, 2 readers can be connected, DI/DQ interface
The Siemens 6GT2002-0JE50 RF186CI is an RFID communication module that connects 2 RF200/300/1000 or MV300/400/500 readers to PROFINET, EtherNet/IP, or OPC UA over Industrial Ethernet at 100 Mbit/s and 8 digital inputs, 8 digital outputs (M12, A-coded, IO-Link expansion). It also provides an RS422/RS232 point-to-point serial link at up to 921.6 kbit/s per reader channel and carries IP67 protection for direct field mounting close to the read points and local I/O.
Certifications & Standards
- EPD
Selection Notes
The built-in 8 DI/8 DO set (expandable through IO-Link modules such as 6ES714x-5xx00-0BL0) lets the RF186CI drive a stop gate, indicator lamp, or reject actuator directly from the RFID node, without routing that logic back through a separate PLC I/O module. Choose it over the plain RF186C whenever the two reader positions need local, low-latency I/O; if no digital I/O is needed, the RF186C covers the same two reader ports for less wiring.
Specification
Full specification
General 3
| product type designation | RF186CI communication module RFID communication module RF186CI for PROFINET, Ethernet, EtherNet/IP, OPC/UA, 2 readers can be connected, DI/DQ interface |
|---|---|
| product brand name | SIMATIC RF |
| suitability for operation | IE / PN network together with RF200/300/1000 MV300/400/500 and digital IO |
Transfer rate 2
| transfer rate / for Industrial Ethernet | 100 Mbit/s |
|---|---|
| transfer rate / at the point-to-point connection / serial / maximum | 921.6 kbit/s |
Interfaces 8
| design of the interface / for point-to-point connection | RS422/RS232 |
|---|---|
| number of readers / connectable | 2 |
| type of electrical connection: of Industrial Ethernet interface | M12, d-coded |
| type of electrical connection: for supply voltage | M12, L-coded |
| design of the interface / to the reader / for communication | M12, 8-pin |
| type of electrical connection / at the digital inputs/outputs | M12, A-coded, for connection of IO-Link expansion modules |
| number of digital inputs | 8 |
| number of digital outputs | 8 |
Show all 77 specifications ↓ Show less ↑64 more values in Identification, Mechanical data, Supply voltage, current consumption, power loss, Ambient conditions, Design, dimensions and weights, Product features, product functions, product components / general, Product functions / management, configuration, engineering, Standards, specifications, approvals, Standards, specifications, approvals / Environmental Product Declaration, Accessories, Logistics.
Identification 10
| Part number | 6GT2002-0JE50 |
|---|---|
| Type designation | RF186CI communication module RFID communication module RF186CI for PROFINET, Ethernet, EtherNet/IP, OPC/UA, 2 readers can be connected, DI/DQ interface |
| Brand | Siemens |
| Condition | New, factory sealed |
| Source | Siemens and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Phase-out announced by the manufacturer |
| EAN | 4047623410133 |
| ETIM class | EC001604 |
| eCl@ss | 27242608 |
Mechanical data 3
| material | Thermoplastic (Valox 467, fiberglass reinforced) |
|---|---|
| color | Al-grey 2001 |
| tightening torque / of the screw for securing the equipment / maximum | 3 N·m |
Supply voltage, current consumption, power loss 5
| supply voltage / at DC: rated value | 24 V |
|---|---|
| supply voltage / at DC: ● | 20.4 ... 28.8 V |
| consumed current: at DC / at 24 V / without connected devices / typical | 0.13 A |
| consumed current: from supply voltage 1L+ / maximum | 4 A |
| continuous current / for loop-through to further bus nodes / at DC / maximum | 12 A |
Ambient conditions 7
| ambient temperature: during operation | -25 ... +55 °C |
|---|---|
| ambient temperature: during storage | -40 ... +70 °C |
| ambient temperature: during transport | -40 ... +70 °C |
| protection class IP | IP67 |
| shock resistance | according to IEC 60068-2-27 and IEC 60068-2-6 |
| shock acceleration | 300 m/s2 |
| vibrational acceleration | 40 m/s2 |
Design, dimensions and weights 5
| width | 60 mm |
|---|---|
| height | 45 mm |
| depth | 165 mm |
| fastening method | 2 M4 screws |
| wire length / for RS 422 interface / maximum | 1000 m |
Product features, product functions, product components / general 14
| display version | 2 LEDs per reader connection, 3 LEDs for device status, 2 LEDs for Ethernet ports |
|---|---|
| protocol / is supported / Media Redundancy Protocol (MRP) | Yes |
| product function / of the PROFINET IO device / is supported / H-Sync forwarding | No |
| product function / addressable transponder file handler | No |
| protocol / is supported: LLDP | Yes |
| protocol / is supported: PROFINET IO protocol | Yes |
| protocol / is supported: TCP/IP | Yes |
| protocol / is supported: SNMP v1 | Yes |
| protocol / is supported: SNMP v2 | No |
| protocol / is supported: SNMP v3 | Yes |
| protocol / is supported: DCP | Yes |
| protocol / is supported: EtherNet/IP protocol | Yes |
| protocol / is supported: OPC UA | Yes |
| product feature / silicon-free | Yes |
Product functions / management, configuration, engineering 3
| type of parameterization | HSP, GSDML, EDS, TO, WBM |
|---|---|
| type of programming | ID profile, library with functions, FB 45, OPC UA, XML |
| type of computer-switched communication | acyclic communication, communication via process image, TCP/IP |
Standards, specifications, approvals 4
| certificate of suitability | CE, FCC, cULus, PNO: Conformance Class B, Netload Class (SL1) III, OPC UA: Embedded UA Server Profile |
|---|---|
| certificate of suitability: IECEx | No |
| MTBF | 65 a |
| product function / is supported / identification link | Yes; acc. to IEC 61406-1:2022 |
Standards, specifications, approvals / Environmental Product Declaration 5
| Environmental Product Declaration | Yes |
|---|---|
| global warming potential [CO2 eq]: total | 101.43 kg |
| global warming potential [CO2 eq]: during manufacturing | 16 kg |
| global warming potential [CO2 eq]: during operation | 85.3 kg |
| global warming potential [CO2 eq]: after end of life | 0.13 kg |
Accessories 1
| accessories | various IO-Link modules for digital IO expansion, e.g. 6ES714x-5xx00-0BL0 |
|---|
Logistics 7
| Net weight | 0.294 kg |
|---|---|
| Package dimensions | 182 × 90 × 50 mm |
| Country of origin | DE |
| Shipping weight | 0.794 kg |
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 01 Nov 2026
Documents
Documents for 6GT2002-0JE50
No documents are on file for this part yet.
Ask us for the datasheet
Certifications
Certifications and standards
- Environmental Product Declaration
Quick answers
Questions about the RF186CI communication module RFID communication module RF186CI for PROFINET, Ethernet, EtherNet/IP, OPC/UA, 2 readers can be connected, DI/DQ interface
What is the rated current of RF186CI communication module RFID communication module RF186CI for PROFINET, Ethernet, EtherNet/IP, OPC/UA, 2 readers can be connected, DI/DQ interface?
The rated current of RF186CI communication module RFID communication module RF186CI for PROFINET, Ethernet, EtherNet/IP, OPC/UA, 2 readers can be connected, DI/DQ interface is 0.13 A.
Which supply voltage is RF186CI communication module RFID communication module RF186CI for PROFINET, Ethernet, EtherNet/IP, OPC/UA, 2 readers can be connected, DI/DQ interface rated for?
The rated operational voltage of RF186CI communication module RFID communication module RF186CI for PROFINET, Ethernet, EtherNet/IP, OPC/UA, 2 readers can be connected, DI/DQ interface is 24 V AC.
What is the HS code of RF186CI communication module RFID communication module RF186CI for PROFINET, Ethernet, EtherNet/IP, OPC/UA, 2 readers can be connected, DI/DQ interface for customs?
The tariff (HS) code on file for RF186CI communication module RFID communication module RF186CI for PROFINET, Ethernet, EtherNet/IP, OPC/UA, 2 readers can be connected, DI/DQ interface is 85176200.
What is the EAN of RF186CI communication module RFID communication module RF186CI for PROFINET, Ethernet, EtherNet/IP, OPC/UA, 2 readers can be connected, DI/DQ interface?
The EAN (GTIN) of RF186CI communication module RFID communication module RF186CI for PROFINET, Ethernet, EtherNet/IP, OPC/UA, 2 readers can be connected, DI/DQ interface is 4047623410133.
Where does RF186CI communication module RFID communication module RF186CI for PROFINET, Ethernet, EtherNet/IP, OPC/UA, 2 readers can be connected, DI/DQ interface ship from, and how fast?
RF186CI communication module RFID communication module RF186CI for PROFINET, Ethernet, EtherNet/IP, OPC/UA, 2 readers can be connected, DI/DQ interface ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.
Reviews
Customer reviews
Series
Siemens SIMATIC RFID
- Brand
- Siemens
- Series
- SIMATIC RFID