Part number
6EP1336-2BA10
Model no
PSU100S
$327.06 In stock · 29 Dispatch Planned dispatch date. We aim to ship within 1 business day. Depending on warehouse workload it can take 2–3 business days. · From Türkiye
SITOP PSU100S

Siemens 6EP1336-2BA10 SITOP PSU100S 24V DC 20A 480W Power Supply

Siemens SITOP PSU100S power supply, 120/230V AC in, 24V DC/20A out, 480W, IP20.

Rated current
20 A
Rated operational voltage
120–230–24–DC V DC
Motor power
0.48 kW
Display
Green LED for 24V OK
EAN
4025515152897
Description

About the PSU100S

The Siemens 6EP1336-2BA10 SITOP PSU100S is a stabilized DIN-rail power supply that converts 120/230 V AC input into a regulated 24 V DC output rated 20 A, delivering 480 W typical active power at 90% efficiency. Output voltage is adjustable from 24 to 28 V via potentiometer, and it carries a signal relay contact for 24 V OK status.

Certifications & Standards

  • CE
  • UKCA
  • EAC
  • CB
  • DNV shipbuilding

Selection Notes

20 A at 24 V DC (480 W) sizes this unit for a mid-size control cabinet feeding several PLC racks, remote I/O, and 24 V field devices from one supply rather than splitting the load across smaller units - the output can also parallel with a second identical unit to raise available current further. Auto-ranging 120/230 V AC input means no manual voltage selection when the same design ships to different line voltages. Derating starts above 45 degrees C ambient at 5%/K, so confirm cabinet ventilation before running near the 20 A rated current in warm enclosures.

Applications

Central 24 V DC bus supply for control cabinets running SIMATIC PLCs, remote I/O, sensors, and DC contactor coils where combined load approaches or exceeds 10-15 A.

Specification

Full specification

132 values · Last verified 01 Nov 2026

General information 4

product brand name SITOP
product type designation PSU100S
product designation Power supply SITOP smart
type of current supply 24 V/20 A

Input 20

type of the power supply network 1-phase AC
phase number 1
voltage curve at input AC
supply voltage at AC Automatic range selection
supply voltage 120 V/230 V
input voltage 1 at AC 85 ... 132 V
input voltage 2 at AC 176 ... 264 V
supply voltage: at 50 Hz 230 V
supply voltage: at 60 Hz 120 V
line frequency 50/60 Hz
wide range input No
overvoltage overload capability 2.3 × Vin rated, 1.3 ms
buffering time for rated value of the output current in the event of power failure minimum 20 ms
operating condition of the mains buffering at Vin = 120/230 V
input current: at rated input voltage 120 V 7.5 A
input current: at rated input voltage 230 V 3.5 A
current limitation of inrush current at 25 °C maximum 11 A
I2t value maximum 10 A2·s
fuse protection type T 10 A (not accessible)
fuse protection type in the feeder Recommended miniature circuit breaker: from 10 A characteristic C or circuit- breaker 3RV2411-1JA10 (120 V) or 3RV2411-1FA10 (230 V)

Output 27

voltage curve at output Controlled, isolated DC voltage
product function output voltage controlled Yes
product function output voltage stabilized Yes
output voltage at DC rated value 24 V
output voltage: at output 1 at DC rated value 24 V
output voltage: at output 1 at DC 24 V
output voltage adjustable Yes; via potentiometer
adjustable output voltage 24 ... 28 V; max. 480 W
relative overall tolerance of the voltage 3%
relative control precision of the output voltage: on slow fluctuation of input voltage 0.5 %
residual ripple: maximum 150 mV
voltage peak: maximum 240 mV
display version for normal operation Green LED for 24 V OK
type of signal at output Relay contact (NO contact, rating 50 V DC/ 0.3 A) for "24 V OK"
behavior of the output voltage when switching on No overshoot of Vout (soft start)
response delay maximum 1.5 s
voltage increase time of the output voltage: typical 50 ms
voltage increase time of the output voltage: maximum 500 ms
output current: rated value 20 A
output current: rated range 0 ... 20 A; 24 A up to +45°C; +60 ... +70 °C: Derating 5%/K
supplied active power typical 480 W
short-term overload current: on short-circuiting during the start-up typical 35 A
short-term overload current: at short-circuit during operation typical 35 A
duration of overloading capability for excess current: on short-circuiting during the start-up 100 ms
duration of overloading capability for excess current: at short-circuit during operation 100 ms
bridging of equipment Yes
number of parallel-switched equipment resources for increasing the power 2
Show all 132 specifications ↓ Show less ↑81 more values in Identification, Efficiency, Closed-loop control, Protection and monitoring, Safety, EMC, Standards, specifications, approvals, Standards, specifications, approvals hazardous environments, Standards, specifications, approvals marine classification, Standards, specifications, approvals Environmental Product Declaration, Ambient conditions, Connection method, Mechanical data, Accessories, Additional information, Approvals Certificates, Logistics.

Identification 10

Part number 6EP1336-2BA10
Type designation PSU100S
Brand Siemens
Condition New, factory sealed
Source Siemens and its authorised distributors
Warranty Manufacturer warranty
Lifecycle status Active, in production
EAN 4025515152897
ETIM class EC002540
eCl@ss 27040701

Efficiency 2

efficiency in percent 90 %
power loss [W]: at rated output voltage for rated value of the output current typical 53 W

Closed-loop control 3

relative control precision of the output voltage with rapid fluctuation of the input voltage by +/- 15% typical 1%
relative control precision of the output voltage load step of resistive load 50/100/50 % typical 3%
setting time: maximum 10 ms

Protection and monitoring 6

design of the overvoltage protection < 60 V
property of the output short-circuit proof Yes
design of short-circuit protection Electronic shutdown, automatic restart
typical 21 A
overcurrent overload capability: in normal operation overload capability 150 % Iout rated up to 5 s/min
enduring short circuit current RMS value: maximum 7 A

Safety 6

galvanic isolation between input and output Yes
galvanic isolation Output voltage: SELV, ES1 (IEC 62368-1), DVC As (IEC 61204-7)
operating resource protection class Class I
leakage current: maximum 3.5 mA
leakage current: typical 1 mA
protection class IP IP20

EMC 3

standard: for emitted interference EN 55022 Class B
standard: for mains harmonics limitation EN 61000-3-2
standard: for interference immunity EN 61000-6-2

Standards, specifications, approvals 8

certificate of suitability: CE marking Yes
certificate of suitability: UL approval Yes; cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259
certificate of suitability: UKCA marking Yes
certificate of suitability: EAC approval Yes
certificate of suitability: NEC Class 2 No
type of certification: BIS Yes; R-41183539
type of certification: CB-certificate Yes
MTBF at 40 °C 1 778 916 h

Standards, specifications, approvals hazardous environments 4

certificate of suitability: IECEx No
certificate of suitability: ATEX No
certificate of suitability: ULhazloc approval No
certificate of suitability: FM registration No

Standards, specifications, approvals marine classification 5

shipbuilding approval Yes
Marine classification association: American Bureau of Shipping Europe Ltd. (ABS) No
Marine classification association: French marine classification society (BV) No
Marine classification association: Det Norske Veritas (DNV) Yes
Marine classification association: Lloyds Register of Shipping (LRS) No

Standards, specifications, approvals Environmental Product Declaration 5

Environmental Product Declaration Yes
global warming potential [CO2 eq]: total 1 707.2 kg
global warming potential [CO2 eq]: during manufacturing 47.4 kg
global warming potential [CO2 eq]: during operation 1 658.2 kg
global warming potential [CO2 eq]: after end of life 0.72 kg

Ambient conditions 4

ambient temperature: during operation 0 ... 70 °C; with natural convection
ambient temperature: during transport -40 ... +85 °C
ambient temperature: during storage -40 ... +85 °C
environmental category according to IEC 60721 Climate class 3K3, 5 ... 95% no condensation

Connection method 4

type of electrical connection screw terminal
at input L1, N, PE: 1 screw terminal each for 0.2 ... 4 mm2 single-core/finely stranded
at output +, -: 2 screw terminals each for 0.2 ... 4 mm2
for auxiliary contacts 13, 14 (alarm signal): 1 screw terminal each for 0.14 ... 1.5 mm2

Mechanical data 11

width × height × depth of the enclosure 115 × 145 × 150 mm
installation width × mounting height 120 mm × 245 mm
required spacing: top 50 mm
required spacing: bottom 50 mm
required spacing: left 0 mm
required spacing: right 0 mm
fastening method Snaps onto DIN rail EN 60715 35x7.5/15
DIN-rail mounting Yes
S7 rail mounting No
wall mounting No
housing can be lined up Yes

Accessories 2

electrical accessories Buffer module
mechanical accessories Device identification label 20 mm × 7 mm, pale turquoise 3RT1900-1SB20

Additional information 1

other information Specifications at rated input voltage and ambient temperature +25 °C (unless otherwise specified)

Approvals Certificates 1

Environmental Product Declaration: global warming potential [CO2 eq] / during manufacturing 47.4 kg

Logistics 6

Net weight 2.4 kg
Country of origin Romania
Shipping weight 2.9 kg
Ships from Türkiye
Dispatch 13 Nov
Stock In stock

Source: manufacturer data · Last verified: 01 Nov 2026

Documents

Documents for 6EP1336-2BA10

No documents are on file for this part yet.

Ask us for the datasheet
Certifications

Certifications and standards

  • CE
  • UKCA
  • CE marking
  • UKCA marking
  • EAC approval
  • CB-certificate
  • shipbuilding approval
  • Det Norske Veritas (DNV)
  • Environmental Product Declaration
Quick answers

Questions about the PSU100S

What is the rated current of PSU100S?

The rated current of PSU100S is 20 A.

Which supply voltage is PSU100S rated for?

The rated operational voltage of PSU100S is 120–230–24–DC V DC.

What motor power is PSU100S rated for?

The rated motor power of PSU100S is 0.48 kW.

What is the HS code of PSU100S for customs?

The tariff (HS) code on file for PSU100S is 85044083.

What is the EAN of PSU100S?

The EAN (GTIN) of PSU100S is 4025515152897.

Where does PSU100S ship from, and how fast?

PSU100S ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival. Stock items are dispatched within 1–2 business days.

Guides

Guides for power supplies

All guides for power supplies
Reviews

Customer reviews

Series

Siemens SITOP PSU100S

Brand
Siemens
Series
SITOP PSU100S
$327.06 In stock · 13 Nov
Quote

Get a Quote

PSU100S

Genuine parts

Genuine, factory-sealed parts

Siemens · 6EP1336-2BA10

Every part on Stoklink is new, unused and made by the manufacturer named on the page.

Condition
New and unused, in the manufacturer's factory-sealed packaging.
Sourced from
Siemens and its authorised distributors.
Warranty
The manufacturer's warranty applies.
If a part is not genuine
We refund the full amount.

Added to cart Could not add to cart