Part number
6EP4683-6LB00-0AY0
Model no
ICL230
$77.63 On request Dispatch — · From TürkiyeGet a Quote
SITOP

Siemens 6EP4683-6LB00-0AY0 LOGO! ICL230 Inrush Current Limiter 100-240V AC 5A Power Supply

LOGO! ICL230 inrush current limiter, 100-240V AC input/output, 5A continuous, limits inrush to 10A for 60ms.

Rated current
5 A
Rated operational voltage
100–240 V AC
Motor power
1.5 W kW
Display
Green LED (normal operation)
EAN
4025515155485
Description

About the ICL230

The Siemens 6EP4683-6LB00-0AY0 is a LOGO! ICL230 inrush current limiter for single-phase 100-240V AC supplies, passing up to 5A continuous while actively limiting inrush current to 10A for 60ms at power-up. It mounts on a DIN rail ahead of downstream power supplies to prevent nuisance tripping of upstream circuit breakers when multiple units switch on together.

Certifications & Standards

  • CE
  • EAC
  • CB

Selection Notes

The ICL230's 5A-rated output means it protects one downstream supply or a small group of supplies whose combined inrush would otherwise trip an upstream breaker on power-up - typical when several SITOP or LOGO! power supplies switch on together from the same feed. Its non-reversible thermal fuse means a sustained overload takes the unit out of service rather than resetting, so it belongs upstream of loads that are not expected to fault repeatedly. Because it passes through the same 100-240V AC voltage it limits, it adds inrush protection without acting as a step-down converter.

Applications

Placed between the mains feed and one or more 24V DC power supplies in a cabinet, it holds the combined inrush current under 10A for the first 60ms so the upstream circuit breaker does not see a nuisance trip when the cabinet is energized.

Specification

Full specification

85 values · Last verified 01 Nov 2026

General information 4

product brand name LOGO!
product type designation ICL230
product designation Switch-on current limitation
type of current supply 100-240 V/5 A

Input 11

type of the power supply network 1-phase AC
phase number 1
voltage curve at input AC
supply voltage at AC: minimum rated value 100 V
supply voltage at AC: maximum rated value 240 V
supply voltage at AC: initial value 85 V
supply voltage at AC: full-scale value 264 V
wide range input Yes
current limitation of inrush current at 25 °C maximum 10 A
duration of inrush current limiting at 25 °C: typical 60 ms
fuse protection type Overload protection in case of error through non-reversible thermal fuse

Output 9

voltage curve at output according to the supply voltage
product function output voltage controlled No
product function output voltage stabilized No
output voltage: at AC rated value 100 - 240 V
output voltage: at AC 85 ... 264
output voltage adjustable No
display version for normal operation Green LED
output current: rated range 0 ... 5 A; Active current limitation for 60 ms to 10 A during switch-on.
bridging of equipment No
Show all 85 specifications ↓ Show less ↑61 more values in Identification, Efficiency, Protection and monitoring, Safety, EMC, Standards, specifications, approvals, Standards, specifications, approvals hazardous environments, Standards, specifications, approvals marine classification, Ambient conditions, Connection method, Mechanical data, Version Classification, Logistics.

Identification 10

Part number 6EP4683-6LB00-0AY0
Type designation ICL230
Brand Siemens
Condition New, factory sealed
Source Siemens and its authorised distributors
Warranty Manufacturer warranty
Lifecycle status Active, in production
EAN 4025515155485
ETIM class EC002540
eCl@ss 27040701

Efficiency 1

power loss [W]: at rated output voltage for rated value of the output current typical 1.5 W

Protection and monitoring 2

design of short-circuit protection must be ensured by primary protection element
overcurrent overload capability: when switching on Switching frequency max. 2 events per minute. Time-limited increased switching frequency once per hour for one minute (typ. 30 events per minute).

Safety 3

electrical separation between input and output No
operating resource protection class Class II
protection class IP IP20

EMC 3

standard: for emitted interference EN 61000-6-3
standard: for mains harmonics limitation -
standard: for interference immunity EN 61000-6-2

Standards, specifications, approvals 5

certificate of suitability: CE marking Yes
certificate of suitability: UL approval Yes; cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259
certificate of suitability: EAC approval Yes
certificate of suitability: NEC Class 2 No
type of certification: CB-certificate Yes

Standards, specifications, approvals hazardous environments 4

certificate of suitability: IECEx No
certificate of suitability: ATEX No
certificate of suitability: ULhazloc approval No
certificate of suitability: FM registration No

Standards, specifications, approvals marine classification 5

shipbuilding approval No
Marine classification association: American Bureau of Shipping Europe Ltd. (ABS) No
Marine classification association: French marine classification society (BV) No
Marine classification association: Det Norske Veritas (DNV) No
Marine classification association: Lloyds Register of Shipping (LRS) No

Ambient conditions 4

ambient temperature: during operation -40 ... +70 °C; with natural convection
ambient temperature: during transport -40 ... +85 °C
ambient temperature: during storage -40 ... +85 °C
environmental category according to IEC 60721 Climate class 3K3, 5 ... 95% no condensation

Connection method 3

type of electrical connection screw terminal
at input L1, N: 1 screw terminal each for 0.5 ... 2.5 mm2
at output L1, N: 1 screw terminal each for 0.5 ... 2.5 mm2

Mechanical data 11

width × height × depth of the enclosure 18 × 90 × 53 mm
installation width × mounting height 18 mm × 130 mm
required spacing: top 20 mm
required spacing: bottom 20 mm
required spacing: left 0 mm
required spacing: right 0 mm
fastening method Snaps onto DIN rail EN 60715 35x7.5/15
DIN-rail mounting Yes
S7 rail mounting No
wall mounting Yes
housing can be lined up Yes

Version Classification 4

eClass 16 27-04-07-01
ETIM 10 EC002540
IDEA 4 4130
UNSPSC 15 39-12-10-04

Logistics 6

Net weight 0.14 kg
Country of origin HU
Shipping weight 0.64 kg
Ships from Türkiye
Dispatch —
Stock On request

Source: manufacturer data · Last verified: 01 Nov 2026

Documents

Documents for 6EP4683-6LB00-0AY0

No documents are on file for this part yet.

Ask us for the datasheet
Certifications

Certifications and standards

  • CE
  • EAC
  • CE marking
  • EAC approval
  • CB-certificate
Quick answers

Questions about the ICL230

What is the rated current of ICL230?

The rated current of ICL230 is 5 A.

Which supply voltage is ICL230 rated for?

The rated operational voltage of ICL230 is 100–240 V AC.

What motor power is ICL230 rated for?

The rated motor power of ICL230 is 1.5 W kW.

What is the HS code of ICL230 for customs?

The tariff (HS) code on file for ICL230 is 85363010.

What is the EAN of ICL230?

The EAN (GTIN) of ICL230 is 4025515155485.

Where does ICL230 ship from, and how fast?

ICL230 ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.

Guides

Guides for power supplies

All guides for power supplies
Reviews

Customer reviews

Series

Siemens SITOP

Brand
Siemens
Series
SITOP
$77.63 On request
Get a Quote
Quote

Get a Quote

ICL230

Genuine parts

Genuine, factory-sealed parts

Siemens · 6EP4683-6LB00-0AY0

Every part on Stoklink is new, unused and made by the manufacturer named on the page.

Condition
New and unused, in the manufacturer's factory-sealed packaging.
Sourced from
Siemens and its authorised distributors.
Warranty
The manufacturer's warranty applies.
If a part is not genuine
We refund the full amount.

Added to cart Could not add to cart