SITOP PSU200M

Siemens 6EP1334-3BA10 SITOP PSU200M 120/230-500V AC to 24V DC 10A Power Supply

SITOP PSU200M, 120/230-500V AC input, 24V DC/10A output, DIN-rail power supply.

Rated current
10 A
Rated operational voltage
120–230 – 230–500 V AC
Motor power
0.24 kW
EAN
4025515152880
Description

About the PSU200M

The Siemens 6EP1334-3BA10 SITOP PSU200M is a DIN-rail power supply converting 120/230-500 V AC input (selector-switch set) to a stabilized 24 V DC output at 10 A, delivering 240 W typical. Efficiency is 91% with a 25 ms buffering time on power loss, adjustable output up to 28.8 V, and a floating alarm relay contact.

Certifications & Standards

  • CE
  • UKCA
  • EAC
  • RCM
  • SEMI F47
  • CB
  • shipbuilding
  • ABS
  • DNV

Selection Notes

The PSU200M 10 A variant runs from a 1- or 2-phase AC input set by an onboard selector switch, either 120-230 V single-phase or 230-500 V, so it must be matched to the site voltage before commissioning rather than relying on a fixed wide-range input. At 240 W typical it sizes above the LOGO!Power class of supplies, and the floating alarm relay contact (30 V DC/0.1 A) reporting overload or shutdown status is worth wiring back to the controller on loads where a fault needs a hardwired signal rather than just an LED indication. A buffer module accessory is listed for extending ride-through beyond the 25 ms internal buffering time.

Applications

Sized for cabinet-level 24 V DC distribution feeding multiple S7-1200 or S7-1500 racks, I/O stations, or contactor coils where 240 W of output and a hardwired alarm signal are needed rather than a single small logic controller supply.

Specification

Full specification

137 values · Last verified 01 Nov 2026

General information 4

product brand name SITOP
product type designation PSU200M
product designation Power supply SITOP modular
type of current supply 24 V/10 A

Input 22

type of the power supply network 1-phase and 2-phase AC
phase number 1
voltage curve at input AC
supply voltage at AC Set by means of selector switch on the device
supply voltage 1 at AC 120 ... 230 V
supply voltage 2 at AC 230 ... 500 V
input voltage 1 at AC 85 ... 264 V
input voltage 2 at AC 176 ... 550 V
supply voltage: at 50 Hz 230 V
supply voltage: at 60 Hz 120 V
line frequency 50/60 Hz
wide range input Yes
overvoltage overload capability 1300 Vpeak, 1.3 ms
buffering time for rated value of the output current in the event of power failure minimum 25 ms
operating condition of the mains buffering at Vin = 120/230 V, typ. 150 ms at Vin = 400 V
input current: at rated input voltage 120 V 4.4 A
input current: at rated input voltage 230 V 2.4 A
input current: at rated input voltage 500 V 1.1 A
current limitation of inrush current at 25 °C maximum 35 A
I2t value maximum 4 A2·s
fuse protection type T 6.3 A (not accessible)
fuse protection type in the feeder Recommended miniature circuit breaker at 1-phase operation: from 6 A (10 A) characteristic C (B); required at 2-phase operation: circuit breaker 2-pole connected or circuit breaker 3RV2011-1EA10 (setting 3.8 A) or 3RV2711- 1ED10 (UL 489) at 230 V; 3RV2011-1DA10 (setting 3 A) or 3RV2711-1DD10 (UL 489) at 400/500 V

Output 25

voltage curve at output Controlled, isolated DC voltage
product function output voltage controlled Yes
product function output voltage stabilized Yes
output voltage at DC rated value 24 V
output voltage: at output 1 at DC rated value 24 V
output voltage: at output 1 at DC 24 V
output voltage adjustable Yes; via potentiometer
adjustable output voltage 24 ... 28.8 V
relative overall tolerance of the voltage 3%
relative control precision of the output voltage: on slow fluctuation of input voltage 0.1 %
residual ripple: maximum 50 mV
voltage peak: maximum 200 mV
display version for normal operation Green LED for 24 V OK
type of signal at output relay contact (normally open, contact rating (SELV (ES1) must be observed): 30 V DC/0.1 A
behavior of the output voltage when switching on Overshoot of Vout approx. 3 %
response delay maximum 1 s
voltage increase time of the output voltage: typical 50 ms
output current: rated value 10 A
output current: rated range 0 ... 10 A; +60 ... +70 °C: Derating 2%/K (at 120 V, 230 V) or 3.5%/K (at 400 V)
supplied active power typical 240 W
short-term overload current: at short-circuit during operation typical 30 A
duration of overloading capability for excess current: at short-circuit during operation 25 ms
constant overload current: on short-circuiting during the start-up typical 12 A
bridging of equipment Yes; switchable characteristic
number of parallel-switched equipment resources for increasing the power 2
Show all 137 specifications ↓ Show less ↑86 more values in Identification, Efficiency, Closed-loop control, Protection and monitoring, EMC, Standards, specifications, approvals, Standards, specifications, approvals hazardous environments, Standards, specifications, approvals marine classification, Standards, specifications, approvals Environmental Product Declaration, Ambient conditions, Connection method, Mechanical data, Accessories, Further information internet links, Additional information, Approvals Certificates, Logistics.

Identification 10

Part number 6EP1334-3BA10
Type designation PSU200M
Brand Siemens
Condition New, factory sealed
Source Siemens and its authorised distributors
Warranty Manufacturer warranty
Lifecycle status Active, in production
EAN 4025515152880
ETIM class EC002540
eCl@ss 27040701

Efficiency 3

efficiency in percent 91 %
power loss [W]: at rated output voltage for rated value of the output current typical 24 W
power loss [W]: during no-load operation maximum 6 W

Closed-loop control 5

relative control precision of the output voltage with rapid fluctuation of the input voltage by +/- 15% typical 0.1 %
relative control precision of the output voltage load step of resistive load 50/100/50 % typical 3%
setting time: load step 50 to 100% typical 2 ms
setting time: load step 100 to 50% typical 2 ms
setting time: maximum 5 ms

Protection and monitoring 12

design of the overvoltage protection < 35 V
property of the output short-circuit proof Yes
design of short-circuit protection Alternatively, constant current characteristic approx. 12 A or latching shutdown
typical 12 A
enduring short circuit current RMS value: typical 12 A
display version for overload and short circuit safety LED yellow for "overload", LED red for "latching shutdown"
galvanic isolation between input and output Yes
galvanic isolation Output voltage: SELV, ES1 (IEC 62368-1), DVC As (IEC 61204-7)
operating resource protection class Class I
leakage current: maximum 3.5 mA
leakage current: typical 0.32 mA
protection class IP IP20

EMC 3

standard: for emitted interference EN 55022 Class B
standard: for mains harmonics limitation EN 61000-3-2
standard: for interference immunity EN 61000-6-2

Standards, specifications, approvals 10

certificate of suitability: CE marking Yes
certificate of suitability: UL approval Yes; cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259
certificate of suitability: UKCA marking Yes
certificate of suitability: EAC approval Yes
certificate of suitability: Regulatory Compliance Mark (RCM) Yes
certificate of suitability: NEC Class 2 No
certificate of suitability: SEMI F47 Yes
type of certification: BIS Yes; R-41183539
type of certification: CB-certificate Yes
MTBF at 40 °C 1 055 408 h

Standards, specifications, approvals hazardous environments 4

certificate of suitability: IECEx No
certificate of suitability: ATEX No
certificate of suitability: ULhazloc approval No
certificate of suitability: FM registration No

Standards, specifications, approvals marine classification 5

shipbuilding approval Yes
Marine classification association: American Bureau of Shipping Europe Ltd. (ABS) Yes
Marine classification association: French marine classification society (BV) No
Marine classification association: Det Norske Veritas (DNV) Yes
Marine classification association: Lloyds Register of Shipping (LRS) No

Standards, specifications, approvals Environmental Product Declaration 5

Environmental Product Declaration Yes
global warming potential [CO2 eq]: total 627.3 kg
global warming potential [CO2 eq]: during manufacturing 19.1 kg
global warming potential [CO2 eq]: during operation 607.7 kg
global warming potential [CO2 eq]: after end of life 0.16 kg

Ambient conditions 4

ambient temperature: during operation -25 ... +70 °C; With natural convection; startup tested starting from -40 °C nominal voltage
ambient temperature: during transport -40 ... +85 °C
ambient temperature: during storage -40 ... +85 °C
environmental category according to IEC 60721 Climate class 3K3, 5 ... 95% no condensation

Connection method 4

type of electrical connection screw terminal
at input L, N, PE: 1 screw terminal each for 0.2 ... 2.5 mm2 single-core/finely stranded
at output +, -: 2 screw terminals each for 0.2 ... 2.5 mm2
for auxiliary contacts 13, 14 (alarm signal): 1 screw terminal each for 0.14 ... 1.5 mm2

Mechanical data 11

width × height × depth of the enclosure 70 × 125 × 121 mm
installation width × mounting height 70 mm × 225 mm
required spacing: top 50 mm
required spacing: bottom 50 mm
required spacing: left 0 mm
required spacing: right 0 mm
fastening method Snaps onto DIN rail EN 60715 35x7.5/15
DIN-rail mounting Yes
S7 rail mounting No
wall mounting No
housing can be lined up Yes

Accessories 1

electrical accessories Buffer module

Additional information 1

other information Specifications at rated input voltage and ambient temperature +25 °C (unless otherwise specified)

Approvals Certificates 1

Environmental Product Declaration: global warming potential [CO2 eq] / during manufacturing 19.1 kg

Logistics 6

Net weight 0.8 kg
Country of origin Romania
Shipping weight 1.3 kg
Ships from Türkiye
Dispatch 13 Nov
Stock In stock

Source: manufacturer data · Last verified: 01 Nov 2026

Documents

Documents for 6EP1334-3BA10

No documents are on file for this part yet.

Ask us for the datasheet
Certifications

Certifications and standards

  • CE marking
  • UKCA marking
  • EAC approval
  • Regulatory Compliance Mark (RCM)
  • SEMI F47
  • CB-certificate
  • shipbuilding approval
  • American Bureau of Shipping Europe Ltd. (ABS)
  • Det Norske Veritas (DNV)
  • Environmental Product Declaration
Quick answers

Questions about the PSU200M

What is the rated current of PSU200M?

The rated current of PSU200M is 10 A.

Which supply voltage is PSU200M rated for?

The rated operational voltage of PSU200M is 120–230 – 230–500 V AC.

What motor power is PSU200M rated for?

The rated motor power of PSU200M is 0.24 kW.

What is the HS code of PSU200M for customs?

The tariff (HS) code on file for PSU200M is 85044083.

What is the EAN of PSU200M?

The EAN (GTIN) of PSU200M is 4025515152880.

Where does PSU200M ship from, and how fast?

PSU200M ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival. Stock items are dispatched within 1–2 business days.

Guides

Guides for power supplies

All guides for power supplies
Reviews

Customer reviews

Series

Siemens SITOP PSU200M

Brand
Siemens
Series
SITOP PSU200M
$291.87 In stock · 13 Nov
Quote

Get a Quote

PSU200M

Genuine parts

Genuine, factory-sealed parts

Siemens · 6EP1334-3BA10

Every part on Stoklink is new, unused and made by the manufacturer named on the page.

Condition
New and unused, in the manufacturer's factory-sealed packaging.
Sourced from
Siemens and its authorised distributors.
Warranty
The manufacturer's warranty applies.
If a part is not genuine
We refund the full amount.

Added to cart Could not add to cart

View cart