What Is a Programmable Logic Controller and How Does It Work
Learn how a PLC works, including scan cycle, I/O sizing, IEC 61131-3 programming, and hardware selection for ABB, Schneider, and Siemens. Shop at Stoklink.
The Siemens 6AV2123-3KB32-0AW0 is a SIMATIC HMI MTP1000 Unified Basic panel with a 10.1-inch widescreen TFT touchscreen, 1280x800 resolution, and 16.7 million colors. It has a PROFINET interface, IP65 protection at the front, and is configurable starting with WinCC Unified Basic V18 Update 3. Power draw is 9.3 W typical at 24 V DC.
Support across the full WinCC Unified and TIA Portal engineering family (Unified Basic, Comfort, PC Engineering, and classic Advanced/Professional) means a project can start on WinCC Unified Basic and later add JavaScript-based task planning or bigger alarm/recipe configurations without swapping hardware. IP65 at the front with NEMA 4/4x when installed supports washdown-adjacent or outdoor-facing mounting, but the rear is only IP20, so the panel still needs a protected cabinet interior behind it. The marine classifications (DNV, KRS, LRS, NK, CCS) make this variant relevant for shipboard control rooms where a standard industrial HMI approval set is not sufficient.
Machine and process operator interfaces needing a 10-inch multitouch widescreen with PROFINET networking, including panels for marine or offshore installations that require classification society approval alongside standard CE/UL compliance.
| Product type designation | MTP1000 Unified Basic |
|---|
| Design of display | TFT |
|---|---|
| Screen diagonal | 10.1 in |
| Display width | 217 mm |
| Display height | 135.6 mm |
| Number of colors | 16 777 216 |
| Resolution (pixels): Horizontal image resolution | 1 280 pixel |
| Resolution (pixels): Vertical image resolution | 800 pixel |
| Backlighting: MTBF backlighting (at 25 °C) | 20 000 h; At 25°C |
| Backlighting: Backlight dimmable | Yes; 10 ... 100% |
| Keyboard: Numeric keyboard | Yes; Onscreen keyboard |
|---|---|
| Keyboard: alphanumeric keyboard | Yes; Onscreen keyboard |
| Touch operation: Design as touch screen | Yes |
| Touch operation: Design as multi-touch screen | Yes |
| Touch operation: Monitor keyboard | Yes |
| Part number | 6AV2123-3KB32-0AW0 |
|---|---|
| Type designation | MTP1000 Unified Basic |
| Brand | Siemens |
| Condition | New, factory sealed |
| Source | Siemens and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| EAN | 4034106035204 |
| ETIM class | EC001412 |
| eCl@ss | 27330201 |
| Mounting position | vertical |
|---|---|
| Mounting in portrait format possible | Yes |
| Mounting in landscape format possible | Yes |
| maximum permissible angle of inclination without external ventilation | 35° |
| Type of supply voltage | DC |
|---|---|
| Rated value (DC) | 24 V |
| permissible range, lower limit (DC) | 19.2 V |
| permissible range, upper limit (DC) | 28.8 V |
| Current consumption (rated value) | 0.28 A |
|---|---|
| current consumption (for rated value of supply voltage), min. | 0.2 A |
| current consumption (for rated value of supply voltage), max. | 0.6 A |
| Current consumption, max. | 0.8 A; at 19.2 V |
| Starting current inrush I2t | 0.36 A2·s |
| Active power input, typ. | 9.3 W |
|---|
| Processor type | ARM |
|---|
| Flash | Yes |
|---|---|
| RAM | Yes |
| Acoustics: Buzzer | No |
|---|---|
| Acoustics: Speaker | No |
| Clock: Hardware clock (real-time) | Yes |
|---|---|
| Clock: Software clock | Yes |
| Clock: retentive | Yes; Back-up duration typically 6 weeks |
| Clock: synchronizable | Yes |
| Number of industrial Ethernet interfaces | 1; Gigabit Ethernet (IE/PN), RJ45 |
|---|---|
| Number of RS 485 interfaces | 0 |
| Number of RS 422 interfaces | 0 |
| Number of USB interfaces | 2; USB 2.0 |
| Number of SD card slots | 0 |
| Industrial Ethernet: Industrial Ethernet status LED | 2 |
| Industrial Ethernet: Number of ports of the integrated switch | 1 |
| PROFINET | Yes |
|---|---|
| Supports protocol for PROFINET IO | No |
| MPI | No |
| Protocols (Ethernet): TCP/IP | Yes |
| Protocols (Ethernet): DHCP | Yes |
| Protocols (Ethernet): SNMP | Yes |
| Protocols (Ethernet): DCP | Yes |
| Protocols (Ethernet): LLDP | Yes |
| Redundancy mode Media redundancy: MRP | No |
| Further protocols: CAN | No |
| Emission of radio interference acc. to EN 55 011: Limit class A, for use in industrial areas | Yes |
|---|
| IP (at the front) | IP65 |
|---|---|
| IP (rear) | IP20 |
| NEMA (front) | NEMA 4, NEMA 4x (when installed) |
| Enclosure Type 4 at the front | Yes |
| Enclosure Type 4x at the front | Yes |
| Enclosure Type 12 at the front | No |
| CE mark | Yes |
|---|---|
| UKCA mark | Yes |
| cULus | Yes |
| FM approval | No |
| RCM (formerly C-TICK) | Yes |
| KC approval | Yes |
| EAC (formerly Gost-R) | No |
| CCC | No |
| Ecological footprint: environmental product declaration Global warming potential | Yes |
| Ecological footprint: global warming potential, (total) [CO2 eq] | 202 kg |
| Ecological footprint: global warming potential, (during production) [CO2 eq] | 41.2 kg |
| Ecological footprint: global warming potential, (during operation) [CO2 eq] | 164 kg |
| Ecological footprint: global warming potential, (after end of life cycle) [CO2 eq] | -3.93 kg |
| Use in hazardous areas: ATEX Zone 2 | No |
| Use in hazardous areas: ATEX Zone 22 | No |
| Use in hazardous areas: IECEx Zone 2 | No |
| Use in hazardous areas: IECEx Zone 22 | No |
| Use in hazardous areas: cULus Class I Zone 2, Division 2 | No |
| Use in hazardous areas: cULus Class II Division 2 | No |
| Use in hazardous areas: FM Class I Division 2 | No |
| Use in hazardous areas: FM Class II Division 2 | No |
| Marine approval: Germanischer Lloyd (GL) | No; included in DNV |
| Marine approval: American Bureau of Shipping (ABS) | Yes; in preparation |
| Marine approval: Bureau Veritas (BV) | Yes; in preparation |
| Marine approval: Det Norske Veritas (DNV) | Yes |
| Marine approval: Korean Register of Shipping (KRS) | Yes |
| Marine approval: Lloyds Register of Shipping (LRS) | Yes |
| Marine approval: Nippon Kaiji Kyokai (Class NK) | Yes |
| Marine approval: Chinese Classification Society (CCS) | Yes |
| Suited for indoor use | Yes |
|---|---|
| Suited for outdoor use | No |
| Ambient temperature during operation Operation (vertical installation): For vertical installation, min. | 0 °C |
| Ambient temperature during storage/transportation: min. | -20 °C |
| Ambient temperature during storage/transportation: max. | 60 °C |
| Relative humidity: Operation, max. | 90 %; no condensation |
| proprietary | Yes |
|---|
| Message indicator | Yes |
|---|---|
| Alarm system (incl. buffer and acknowledgment) | Yes |
| Recipe management | Yes |
| Configuration software: WinCC Advanced (TIA Portal) | Yes |
| Configuration software: WinCC Professional (TIA Portal) | Yes |
| Configuration software: WinCC Unified Basic Engineering (TIA Portal) | Yes |
| Configuration software: WinCC Unified Comfort Engineering (TIA Portal) | Yes |
| Configuration software: WinCC Unified PC Engineering (TIA Portal) | Yes |
| Online languages: Number of online/runtime languages | 32 |
|---|---|
| Project languages: Languages per project | 32 |
| Libraries | Yes |
|---|---|
| Applications/options | No |
| Number of Visual Basic Scripts | No |
| JavaScript | Yes |
| Task planner: time-controlled | Yes |
| Task planner: task-controlled | Yes |
| Help system: Number of characters per info text | 70 |
| Help system: Number of message texts per message | 10 |
| Message system: Number of alarm classes | 32 |
| Bit messages: Number of bit messages | 2 000 |
| Analog messages: Number of analog messages | 100 |
| Analog messages: S7 alarm number procedure | Yes |
| Analog messages: System messages HMI | Yes |
| Analog messages: System event, more (SIMATIC S7, SINUMERIK, SIMOTION, ... ) | Yes |
| Analog messages: Number of characters per message | 512 |
| Analog messages: Number of process values per message | 10 |
| Analog messages: Acknowledgment groups | Yes |
| Analog messages: Message indicator | No |
| Analog messages: Message buffer | Yes; Configured as alarm archive |
| Analog messages: Circulating buffer | Yes |
| Analog messages: retentive | Yes |
| Analog messages: maintenance-free | Yes |
| Parameter set management (recipes): Number of parameter set types | 250 |
| Parameter set management (recipes): Parameter sets per parameter set type | 250 |
| Parameter set management (recipes): Entries per parameter set | 250 |
| Parameter set management (recipes): Size of internal parameter set memory | 5 Mbyte |
| Parameter set management (recipes): Parameter set memory expandable | Yes |
| Variables: Number of variables per device | 1 000 |
| Variables: Number of variables per screen | 300 |
| Variables: Limit values | Yes |
| Variables: Structures | Yes |
| Variables: Arrays | Yes |
| Images: Number of configurable images | 300 |
| Images: Faceplate | Yes |
| Image objects: Number of objects per image | 600 |
| Image objects: Picture window | Yes |
| Image objects: Text fields | Yes |
| Image objects: I/O fields | Yes |
| Image objects: Graphic I/O fields (graphics list) | Yes |
| Image objects: Symbolic I/O fields (text list) | Yes |
| Image objects: Scalable Vector Graphics (SVG) | Yes |
| Image objects: Date/time fields | Yes |
| Image objects: Checkbox | Yes |
| Image objects: Option button | Yes |
| Image objects: Switches | Yes |
| Image objects: Buttons | Yes |
| Image objects: Graphic display | Yes |
| Image objects: Icons | Yes |
| Image objects: Custom web display | No |
| Image objects: Geometric objects | Yes |
| Complex image objects: Number of complex objects per screen | 5 |
| Complex image objects: Alarm view | Yes |
| Complex image objects: Trend view | Yes |
| Complex image objects: User view | Yes |
| Complex image objects: Status/control | Yes |
| Complex image objects: Parameter set display | Yes |
| Complex image objects: HTML browser | Yes |
| Complex image objects: Bar graphs | Yes |
| Complex image objects: Sliders | Yes |
| Complex image objects: Pointer instruments | Yes |
| Complex image objects: Analog/digital clock | Yes |
| Lists: Number of text lists per project | 300 |
| Lists: Number of entries per text list | 250 |
| Lists: Number of graphics lists per project | 100 |
| Lists: Number of entries per graphics list | 250 |
| Archiving: Number of archives per device | 10 |
| Archiving: Number of entries per archive | 50 000 |
| Archiving: Message archive | Yes |
| Archiving: Process value archive | Yes |
| Archiving methods: Sequential archive | Yes |
| Archiving methods: Short-term archive | Yes |
| Memory location: Memory card | No |
| Memory location: USB memory | Yes |
| Memory location: Ethernet | No |
| Security: Number of roles | 50 |
| Security: Number of function rights | 20; V18 |
| Security: Number of users | 200 |
| Security: Password export/import | Yes |
| Security: Central user administration | Yes |
| Transfer (upload/download): USB | Yes |
| Transfer (upload/download): Ethernet | Yes |
| Transfer (upload/download): using external storage medium | Yes |
| Process coupling: S7-1200 | Yes |
| Process coupling: S7-1500 | Yes |
| Process coupling: S7-200 | No |
| Process coupling: S7-300/400 | Yes |
| Process coupling: Number of S7 connections | 8 |
| Process coupling: LOGO! | Yes; as of WinCC Unified V20 |
| Process coupling: SIMOTION | No |
| Process coupling: OPC UA Client | Yes |
| Process coupling: OPC UA Server | No |
| Process coupling: Software Controller/Open Controller | No |
| Service tools/configuration aids: Backup/Restore manually | Yes |
| Service tools/configuration aids: Backup/Restore automatically | No |
| Service tools/configuration aids: Simulation | Yes |
| Service tools/configuration aids: Device switchover | Yes |
| Peripherals | Barcode reader |
|---|---|
| Printer | No |
| SIMATIC HMI MM memory card: Multi Media Card | No |
| SIMATIC HMI SD memory card: Secure Digital memory card | No |
| SIMATIC HMI CF memory card Compact Flash Card | No |
| USB memory | Yes |
| SIMATIC IPC USB Flashdrive (USB stick) | Yes |
| SIMATIC HMI USB stick | Yes |
| Network camera | No |
| Enclosure material (front): Plastic | Yes |
|---|
| Width of the housing front | 280 mm |
|---|---|
| Height of housing front | 205 mm |
| Mounting cutout, width | 264 mm |
| Mounting cutout, height | 189 mm |
| mounting depth | 55 mm |
| Weight (without packaging) | 1.55 kg |
|---|---|
| Weight (with packaging) | 2.22 kg |
| Net weight | 1.5 kg |
|---|---|
| Package dimensions | 397 × 300 × 128 mm |
| Country of origin | CN |
| Shipping weight | 2.0 kg |
| Ships from | Türkiye |
| Dispatch | 13 Nov |
| Stock | In stock |
Source: manufacturer data · Last verified: 01 Nov 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated current of MTP1000 Unified Basic is 0.28 A.
The rated operational voltage of MTP1000 Unified Basic is 24 V AC.
The tariff (HS) code on file for MTP1000 Unified Basic is 85371091.
The EAN (GTIN) of MTP1000 Unified Basic is 4034106035204.
MTP1000 Unified Basic ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival. Stock items are dispatched within 1–2 business days.
Learn how a PLC works, including scan cycle, I/O sizing, IEC 61131-3 programming, and hardware selection for ABB, Schneider, and Siemens. Shop at Stoklink.
Compare ABB, Siemens, and Schneider Electric across motor control, energy efficiency, installation, support, and power distribution. Shop at Stoklink.
Contactors deliver safe, reliable motor control and automation switching for industrial systems, lighting, pumps, and heating loads. Shop at Stoklink.