- Part number
- 3TK2810-1BA42
- Model no
- 3TK28
Description
About the 3TK28
About the 3TK28
The Siemens 3TK2810-1BA42 is a relay from the SENTRON/SIRIUS 3TK2 series. SIRIUS safety relay Safety-oriented Speed monitoring 24 V DC, 45 mm overall width Spring-type terminal EC instantaneous: 2 NO EC delayed: 0 SC: 2 electrical Auto-start/manual start Basic device Maximum achievable PL according to EN 13849-1: e Maximum achievable SIL according to IEC 61508: 3. Supplied by Stoklink for industrial and commercial low-voltage applications.
Certifications & Standards
- EN 13849-1
- IEC 61508
- EN 60947-5
Applications & Use Cases
The Siemens 3TK2810-1BA42 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3TK2 range it integrates with compatible SENTRON/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.
Specification
Full specification
General 4
| product brand name | SIRIUS |
|---|---|
| product designation | Speed monitor |
| design of the product | standstill and speed monitoring |
| product type designation | 3TK28 |
Product Function 23
| product function: automatic start | Yes |
|---|---|
| product function: light barrier monitoring | No |
| product function: standstill monitoring | Yes |
| product function: protective door monitoring | Yes |
| product function: magnetically operated switch monitoring NC-NO | No |
| product function: rotation speed monitoring | Yes |
| product function: laser scanner monitoring | No |
| product function: light array monitoring | No |
| product function: EMERGENCY OFF function | Yes |
| product function: monitored start-up | Yes |
| product function: pressure-sensitive mat monitoring | No |
| product feature cross-circuit-proof | Yes |
| suitability for interaction press control | No |
| suitability for use: monitoring of floating sensors | Yes |
| suitability for use: monitoring of non-floating sensors | No |
| suitability for use: position switch monitoring | Yes |
| suitability for use: EMERGENCY-OFF circuit monitoring | No |
| suitability for use: valve monitoring | No |
| suitability for use: opto-electronic protection device monitoring | No |
| suitability for use: tactile sensor monitoring | No |
| suitability for use: magnetically operated switch monitoring | No |
| suitability for use: proximity switch monitoring | Yes |
| suitability for use: safety-related circuits | Yes |
General technical data 9
| certificate of suitability UL approval | Yes |
|---|---|
| insulation voltage rated value | 300 V |
| surge voltage resistance rated value | 4 000 V |
| protection class IP: of the enclosure | IP20 |
| shock resistance | 8 g / 10 ms |
| vibration resistance according to IEC 60068-2-6 | 10 ... 55 Hz: 0.35 mm |
| electrical endurance (operating cycles) typical | 100 000 |
| Substance Prohibitance (day/month/year) | 05/01/2012 |
| SVHC substance name | Lead CAS-No. 7439-92-1 |
Show all 127 specifications ↓ Show less ↑91 more values in Identification, Ambient conditions, Electromagnetic compatibility, Safety related data, IEC 62061, ISO 13849, IEC 61508, Electrical Safety, Short-circuit protection, Inputs, Outputs, Encoder, Proximity switch, Control circuit/ Control, Installation/ mounting/ dimensions, Connections/ Terminals, Logistics.
Identification 10
| Part number | 3TK2810-1BA42 |
|---|---|
| Type designation | 3TK28 |
| Brand | Siemens |
| Condition | New, factory sealed |
| Source | Siemens and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| EAN | 4011209860346 |
| ETIM class | EC001449 |
| eCl@ss | 27371819 |
Ambient conditions 6
| installation altitude at height above sea level maximum | 2 000 m |
|---|---|
| note | installation altitude: 5000 m with derating |
| ambient temperature: during operation | 0 ... 60 °C; from an operating altitude > 2000 m, the maximum permissible temperature is reduced by 0.5 °C / 100 m |
| ambient temperature: during storage | -20 ... +70 °C |
| relative humidity during operation | 10 ... 95 % |
| air pressure according to SN 31205 | 90 ... 106 kPa |
Electromagnetic compatibility 2
| installation environment regarding EMC | This product is suitable for Class A environments only. In household environments, this device can cause unwanted radio interference. The user is required to implement appropriate measures in this case. |
|---|---|
| EMC emitted interference | EN 60947-5-1 |
IEC 62061 3
| SIL Claim Limit (subsystem) according to EN 62061 | 3 |
|---|---|
| Safety Integrity Level (SIL) according to IEC 62061 | SIL 3 |
| PFHD with high demand rate according to IEC 62061 | 3.4E-9 1/h |
ISO 13849 3
| category according to EN ISO 13849-1 | 4 |
|---|---|
| performance level (PL): according to ISO 13849-1 | PL e |
| performance level (PL): for delayed release circuit according to ISO 13849-1 | e |
IEC 61508 5
| Safety Integrity Level (SIL): according to IEC 61508 | 3 |
|---|---|
| Safety Integrity Level (SIL): for delayed release circuit according to IEC 61508 | SIL3 |
| safety device type according to IEC 61508-2 | Type B |
| hardware fault tolerance according to IEC 61508 | 1 |
| T1 value for proof test interval or service life according to IEC 61508 | 20 a |
Electrical Safety 1
| touch protection against electrical shock | finger-safe |
|---|
Short-circuit protection 1
| design of the fuse link for short-circuit protection of the NO contacts of the relay outputs required | gL/gG: 4 A |
|---|
Inputs 5
| design of input: cascading input/functional switching | No |
|---|---|
| design of input: feedback input | Yes |
| design of input: start input | Yes |
| number of sensor inputs: 1-channel or 2-channel | 0 |
| number of sensor inputs: 2-channel | 3 |
Outputs 18
| as NC contact: for signaling function instantaneous contact | 0 |
|---|---|
| as NC contact: for signaling function delayed switching | 0 |
| as NC contact: safety-related instantaneous contact | 0 |
| as NC contact: safety-related delayed switching | 0 |
| as NO contact: for signaling function instantaneous contact | 0 |
| as NO contact: for signaling function delayed switching | 0 |
| as NO contact: safety-related instantaneous contact | 1 |
| as NO contact: safety-related delayed switching | 1 |
| mechanical service life (operating cycles) typical | 50 000 000 |
| thermal current of the switching element with contacts maximum | 5 A |
| for signaling function: delayed switching | 1 |
| for signaling function: instantaneous contact | 1 |
| safety-related: delayed switching | 0 |
| safety-related: instantaneous contact | 0 |
| switching capacity current of semiconductor outputs: for signaling function at DC-13 at 24 V | 0.02 A |
| switching capacity current of the NO contacts of the relay outputs at DC-13: at 24 V | 2 A |
| switching capacity current of the NC contacts of the relay outputs at AC-15: at 24 V | 3 A |
| type of switching output | optionally PNP or NPN |
Encoder 3
| encoder signal evaluation | two signal tracks each with inverted signals |
|---|---|
| type of signal level of the encoder | optionally TTL, HTL or sin/cos (Ua = 1Vss) |
| type of failure response of the encoder | high-resistance |
Proximity switch 9
| type of voltage of the supply voltage of proximity switches | DC |
|---|---|
| supply voltage of proximity switches | 24 V; provided by the device |
| current consumption of proximity switches maximum | 30 mA |
| input voltage for proximity switch minimum | 10 V |
| pulse duration of proximity switches minimum | 75 µs |
| interpulse period of proximity switches minimum | 75 µs |
| adjustment range of signal frequency of proximity switches | 1 Hz ... 2 kHz |
| measuring precision | +-2 % |
| switching hysteresis | 6.25 % |
Control circuit/ Control 3
| type of voltage of the control supply voltage | DC |
|---|---|
| control supply voltage 1 at DC rated value | 24 V |
| operating range factor control supply voltage rated value of magnet coil at DC: initial value | 0.9 |
Installation/ mounting/ dimensions 5
| mounting position | any |
|---|---|
| fastening method | screw and snap-on mounting |
| height | 107.7 mm |
| width | 45 mm |
| depth | 124.3 mm |
Connections/ Terminals 9
| type of electrical connection | spring-loaded terminals |
|---|---|
| type of connectable conductor cross-sections: solid | 1x (0.5 ... 4 mm2) |
| type of connectable conductor cross-sections: finely stranded with core end processing | 2 x (0.25 ... 1.5 mm2) |
| type of connectable conductor cross-sections: for AWG cables solid | 2x (24 ... 16) |
| connectable conductor cross-section: solid | 0.25 ... 1.5 mm2 |
| connectable conductor cross-section: finely stranded with core end processing | 0.25 ... 1.5 mm2 |
| connectable conductor cross-section: finely stranded without core end processing | 0.25 ... 1.5 mm2 |
| AWG number as coded connectable conductor cross section: solid | 24 ... 16 |
| AWG number as coded connectable conductor cross section: stranded | 24 ... 16 |
Logistics 6
| Net weight | 0.414 kg |
|---|---|
| Package dimensions | 128 × 112 × 54 mm |
| Country of origin | DE |
| Shipping weight | 0.914 kg |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 31 Oct 2026
Documents
Documents for 3TK2810-1BA42 1
-
Datasheet
ProductDownload PDF: Product data sheet 3TK2810-1BA42
Product data sheet 3TK2810-1BA42
Certifications
Certifications and standards
- EN 13849-1
- IEC 61508
- EN 60947-5
Quick answers
Questions about the 3TK28
What is the rated current of 3TK28?
The rated current of 3TK28 is 5 A.
Which supply voltage is 3TK28 rated for?
The rated operational voltage of 3TK28 is 24 V AC.
What is the HS code of 3TK28 for customs?
The tariff (HS) code on file for 3TK28 is 85364190.
What is the EAN of 3TK28?
The EAN (GTIN) of 3TK28 is 4011209860346.
How is 3TK28 delivered, and how fast?
3TK28 ships worldwide by express courier, with tracking. Shipping and import duties calculated at checkout · nothing to pay on delivery.
Reviews
Customer reviews
Series
Siemens 3TK2
- Brand
- Siemens
- Series
- 3TK2