Part number
3TK2810-1KA42
Model no
3TK28
$1,423.75 On request Dispatch —· Worldwide delivery
3TK2

Siemens 3TK2810-1KA42 3TK2 240V Relay

Rated current
5 A
Control voltage
110–240–DC V
EAN
4011209860353
Description

About the 3TK28

The Siemens 3TK2810-1KA42 is a relay from the SENTRON/SIRIUS 3TK2 series. SIRIUS safety relay Safety-oriented Speed monitoring 110-240 V AC/DC, 45 mm overall width Spring-type terminal EC instantaneous: 2 NO EC delayed: 0 SC: 2 electrical Auto-start/manual start Basic device Maximum achievable PL according to EN 13849-1: e Maximum achievable SIL according to IEC 61508: 3. Supplied by Stoklink for industrial and commercial low-voltage applications.

Certifications & Standards

  • EN 13849-1
  • IEC 61508
  • EN 60947-5

Applications & Use Cases

The Siemens 3TK2810-1KA42 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3TK2 range it integrates with compatible SENTRON/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.

Specification

Full specification

131 values · Last verified 31 Oct 2026

General 4

product brand name SIRIUS
product designation Speed monitor
design of the product standstill and speed monitoring
product type designation 3TK28

Product Function 23

product function: automatic start Yes
product function: light barrier monitoring No
product function: standstill monitoring Yes
product function: protective door monitoring Yes
product function: magnetically operated switch monitoring NC-NO No
product function: rotation speed monitoring Yes
product function: laser scanner monitoring No
product function: light array monitoring No
product function: EMERGENCY OFF function Yes
product function: monitored start-up Yes
product function: pressure-sensitive mat monitoring No
product feature cross-circuit-proof Yes
suitability for interaction press control No
suitability for use: monitoring of floating sensors Yes
suitability for use: monitoring of non-floating sensors No
suitability for use: position switch monitoring Yes
suitability for use: EMERGENCY-OFF circuit monitoring No
suitability for use: valve monitoring No
suitability for use: opto-electronic protection device monitoring No
suitability for use: tactile sensor monitoring No
suitability for use: magnetically operated switch monitoring No
suitability for use: proximity switch monitoring Yes
suitability for use: safety-related circuits Yes

General technical data 9

certificate of suitability UL approval Yes
insulation voltage rated value 300 V
surge voltage resistance rated value 4 000 V
protection class IP: of the enclosure IP20
shock resistance 8 g / 10 ms
vibration resistance according to IEC 60068-2-6 10 ... 55 Hz: 0.35 mm
electrical endurance (operating cycles) typical 100 000
Substance Prohibitance (day/month/year) 05/01/2012
SVHC substance name Lead monoxide (lead oxide) CAS-No. 1317-36-8
Show all 131 specifications ↓ Show less ↑95 more values in Identification, Ambient conditions, Electromagnetic compatibility, Safety related data, IEC 62061, ISO 13849, IEC 61508, Electrical Safety, Short-circuit protection, Inputs, Outputs, Encoder, Proximity switch, Control circuit/ Control, Installation/ mounting/ dimensions, Connections/ Terminals, Logistics.

Identification 10

Part number 3TK2810-1KA42
Type designation 3TK28
Brand Siemens
Condition New, factory sealed
Source Siemens and its authorised distributors
Warranty Manufacturer warranty
Lifecycle status Active, in production
EAN 4011209860353
ETIM class EC001449
eCl@ss 27371819

Ambient conditions 6

installation altitude at height above sea level maximum 2 000 m
note installation altitude: 5000 m with derating
ambient temperature: during operation 0 ... 60 °C; from an operating altitude > 2000 m, the maximum permissible temperature is reduced by 0.5 °C / 100 m
ambient temperature: during storage -20 ... +70 °C
relative humidity during operation 10 ... 95 %
air pressure according to SN 31205 90 ... 106 kPa

Electromagnetic compatibility 2

installation environment regarding EMC This product is suitable for Class A environments only. In household environments, this device can cause unwanted radio interference. The user is required to implement appropriate measures in this case.
EMC emitted interference EN 60947-5-1

IEC 62061 3

SIL Claim Limit (subsystem) according to EN 62061 3
Safety Integrity Level (SIL) according to IEC 62061 SIL 3
PFHD with high demand rate according to IEC 62061 3.4E-9 1/h

ISO 13849 3

category according to EN ISO 13849-1 4
performance level (PL): according to ISO 13849-1 PL e
performance level (PL): for delayed release circuit according to ISO 13849-1 e

IEC 61508 5

Safety Integrity Level (SIL): according to IEC 61508 3
Safety Integrity Level (SIL): for delayed release circuit according to IEC 61508 SIL3
safety device type according to IEC 61508-2 Type B
hardware fault tolerance according to IEC 61508 1
T1 value for proof test interval or service life according to IEC 61508 20 a

Electrical Safety 1

touch protection against electrical shock finger-safe

Short-circuit protection 1

design of the fuse link for short-circuit protection of the NO contacts of the relay outputs required gL/gG: 4 A

Inputs 5

design of input: cascading input/functional switching No
design of input: feedback input Yes
design of input: start input Yes
number of sensor inputs: 1-channel or 2-channel 0
number of sensor inputs: 2-channel 3

Outputs 18

as NC contact: for signaling function instantaneous contact 0
as NC contact: for signaling function delayed switching 0
as NC contact: safety-related instantaneous contact 0
as NC contact: safety-related delayed switching 0
as NO contact: for signaling function instantaneous contact 0
as NO contact: for signaling function delayed switching 0
as NO contact: safety-related instantaneous contact 1
as NO contact: safety-related delayed switching 1
mechanical service life (operating cycles) typical 50 000 000
thermal current of the switching element with contacts maximum 5 A
for signaling function: delayed switching 1
for signaling function: instantaneous contact 1
safety-related: delayed switching 0
safety-related: instantaneous contact 0
switching capacity current of semiconductor outputs: for signaling function at DC-13 at 24 V 0.02 A
switching capacity current of the NO contacts of the relay outputs at DC-13: at 24 V 2 A
switching capacity current of the NC contacts of the relay outputs at AC-15: at 24 V 3 A
type of switching output optionally PNP or NPN

Encoder 3

encoder signal evaluation two signal tracks each with inverted signals
type of signal level of the encoder optionally TTL, HTL or sin/cos (Ua = 1Vss)
type of failure response of the encoder high-resistance

Proximity switch 9

type of voltage of the supply voltage of proximity switches DC
supply voltage of proximity switches 24 V; provided by the device
current consumption of proximity switches maximum 30 mA
input voltage for proximity switch minimum 10 V
pulse duration of proximity switches minimum 75 µs
interpulse period of proximity switches minimum 75 µs
adjustment range of signal frequency of proximity switches 1 Hz ... 2 kHz
measuring precision +-2 %
switching hysteresis 6.25 %

Control circuit/ Control 7

type of voltage of the control supply voltage AC/DC
control supply voltage 1 at AC: at 50 Hz 110 ... 240 V
control supply voltage 1 at AC: at 60 Hz 110 ... 240 V
control supply voltage frequency: 1 rated value 50 Hz
control supply voltage frequency: 2 rated value 60 Hz
control supply voltage 1 at DC 110 ... 240 V
operating range factor control supply voltage rated value of magnet coil at DC: initial value 0.8

Installation/ mounting/ dimensions 5

mounting position any
fastening method screw and snap-on mounting
height 107.7 mm
width 45 mm
depth 124.3 mm

Connections/ Terminals 9

type of electrical connection spring-loaded terminals
type of connectable conductor cross-sections: solid 1x (0.5 ... 4 mm2)
type of connectable conductor cross-sections: finely stranded with core end processing 2 x (0.25 ... 1.5 mm2)
type of connectable conductor cross-sections: for AWG cables solid 2x (24 ... 16)
connectable conductor cross-section: solid 0.25 ... 1.5 mm2
connectable conductor cross-section: finely stranded with core end processing 0.25 ... 1.5 mm2
connectable conductor cross-section: finely stranded without core end processing 0.25 ... 1.5 mm2
AWG number as coded connectable conductor cross section: solid 24 ... 16
AWG number as coded connectable conductor cross section: stranded 24 ... 16

Logistics 6

Net weight 0.414 kg
Package dimensions 129 × 110 × 55 mm
Country of origin DE
Shipping weight 0.914 kg
Dispatch —
Stock On request

Source: manufacturer data · Last verified: 31 Oct 2026

Documents

Documents for 3TK2810-1KA42 1

Certifications

Certifications and standards

  • EN 13849-1
  • IEC 61508
  • EN 60947-5
Quick answers

Questions about the 3TK28

What is the rated current of 3TK28?

The rated current of 3TK28 is 5 A.

Which control voltage does 3TK28 need?

The control voltage range of 3TK28 is 110–240–DC V.

What is the HS code of 3TK28 for customs?

The tariff (HS) code on file for 3TK28 is 85364900.

What is the EAN of 3TK28?

The EAN (GTIN) of 3TK28 is 4011209860353.

How is 3TK28 delivered, and how fast?

3TK28 ships worldwide by express courier, with tracking. Shipping and import duties calculated at checkout · nothing to pay on delivery.

Reviews

Customer reviews

Series

Siemens 3TK2

Brand
Siemens
Series
3TK2
$1,423.75 On request
Quote

Get a Quote

3TK28

Genuine parts

Genuine, factory-sealed parts

Siemens · 3TK2810-1KA42

Every part on Stoklink is new, unused and made by the manufacturer named on the page.

Condition
New and unused, in the manufacturer's factory-sealed packaging.
Sourced from
Siemens and its authorised distributors.
Warranty
The manufacturer's warranty applies.
If a part is not genuine
We refund the full amount.

Added to cart Could not add to cart

View cart