Part number
3SK1220-2AB40
Model no
3SK1
$160.10 On request Dispatch —· Worldwide delivery
3SK1

Siemens 3SK1220-2AB40 3SK1 24V Safety Relay

Control voltage
24 V
EAN
4011209913875
Description

About the 3SK1

The Siemens 3SK1220-2AB40 is a safety relay from the SENTRON/SIRIUS 3SK1 series. SIRIUS safety relay Input expansion Advanced Input expansion for an additional 2-channel or two 1-channel sensors Us = 24 V DC Spring-type terminal (push-in). Supplied by Stoklink for industrial and commercial low-voltage applications.

Certifications & Standards

  • IEC 60947-5

Applications & Use Cases

The Siemens 3SK1220-2AB40 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3SK1 range it integrates with compatible SENTRON/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.

Specification

Full specification

129 values · Last verified 31 Oct 2026

General 4

product brand name SIRIUS
product category Safety relays
product designation Sensor extension
product type designation 3SK1

Product Function 19

product function parameterizable sensor floating / sensor non-floating, monitored start-up / automatic start, 1- channel / 2-channel sensor connection, cross-circuit detection, startup testing, antivalent sensors, 2-hand switches
product function: automatic start Yes
product function: light barrier monitoring Yes
product function: protective door monitoring Yes
product function: magnetically operated switch monitoring NC-NO Yes
product function: laser scanner monitoring Yes
product function: light array monitoring Yes
product function: EMERGENCY OFF function Yes
product function: monitored start-up Yes
product function: pressure-sensitive mat monitoring No
product feature cross-circuit-proof Yes
suitability for interaction press control No
suitability for use: monitoring of floating sensors Yes
suitability for use: monitoring of non-floating sensors Yes
suitability for use: position switch monitoring Yes
suitability for use: EMERGENCY-OFF circuit monitoring Yes
suitability for use: opto-electronic protection device monitoring Yes
suitability for use: magnetically operated switch monitoring Yes
suitability for use: safety-related circuits Yes

General technical data 13

certificate of suitability UL approval Yes
product feature protective coating on printed-circuit board No
power loss [W] maximum 1.2 W
insulation voltage rated value 50 V
degree of pollution 3
overvoltage category 3
surge voltage resistance rated value 800 V
protection class IP of the enclosure IP20
shock resistance 10 g / 11 ms
vibration resistance according to IEC 60068-2-6 5 ... 500 Hz: 0.75 mm
reference code according to IEC 81346-2 F
Substance Prohibitance (day/month/year) 11/05/2012
SVHC substance name Lead CAS-No. 7439-92-1 Lead monoxide (lead oxide) CAS-No. 1317-36-8 2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-No. 71868- 10-5 Melamine CAS-No. 108-78-1 6,6'-di-tert-butyl-2,2'-methylenedi-p-cresol CAS-No. 119-47-1
Show all 129 specifications ↓ Show less ↑93 more values in Identification, Ambient conditions, Electromagnetic compatibility, Safety related data, IEC 62061, ISO 13849, IEC 61508, Electrical Safety, Inputs, Outputs, Times, Control circuit/ Control, Installation/ mounting/ dimensions, Connections/ Terminals, Logistics.

Identification 10

Part number 3SK1220-2AB40
Type designation 3SK1
Brand Siemens
Condition New, factory sealed
Source Siemens and its authorised distributors
Warranty Manufacturer warranty
Lifecycle status Active, in production
EAN 4011209913875
ETIM class EC001449
eCl@ss 27371819

Ambient conditions 6

installation altitude at height above sea level maximum 4 000 m
note Derating, see Product Notification 109792701
ambient temperature: during operation -25 ... +60 °C
ambient temperature: during storage -40 ... +80 °C
relative humidity during operation 10 ... 95 %
air pressure according to SN 31205 900 ... 1 060 hPa

Electromagnetic compatibility 2

installation environment regarding EMC This product is suitable for Class A environments only. In household environments, this device can cause unwanted radio interference. The user is required to implement appropriate measures in this case.
EMC emitted interference IEC 60947-5-1, Class A

IEC 62061 5

SIL Claim Limit (subsystem) according to EN 62061 3
Safety Integrity Level (SIL): according to IEC 62061 SIL 3
Safety Integrity Level (SIL): at single-channel evaluation according to IEC 62061 1
Safety Integrity Level (SIL): at 2-channel evaluation according to IEC 62061 3
PFHD with high demand rate according to IEC 62061: ● 1E-9 1/h

ISO 13849 7

category according to EN ISO 13849-1 4
performance level (PL): according to ISO 13849-1 PL e
performance level (PL): at single-channel evaluation according to ISO 13849-1 c
performance level (PL): at 2-channel evaluation according to ISO 13849-1 e
category: according to ISO 13849-1 4
category: at 2-channel evaluation according to ISO 13849-1 4
device type according to ISO 13849-1 1

IEC 61508 12

Safety Integrity Level (SIL): according to IEC 61508 3
Safety Integrity Level (SIL): at single-channel evaluation according to IEC 61508 1
Safety Integrity Level (SIL): at 2-channel evaluation according to IEC 61508 3
safety device type according to IEC 61508-2 Type B
PFHD with high demand rate according to IEC 61508 1E-9 1/h
PFDavg with low demand rate according to IEC 61508: ● 1E-5
Safe failure fraction (SFF) 99 %
hardware fault tolerance: according to IEC 61508 1
hardware fault tolerance: at single-channel evaluation according to IEC 61508 0
hardware fault tolerance: at 2-channel evaluation according to IEC 61508 1
T1 value: of service life according to IEC 61508 20 a
T1 value: for proof test interval or service life according to IEC 61508 20 a

Electrical Safety 1

touch protection against electrical shock finger-safe

Inputs 3

design of input: feedback input No
design of input: start input Yes
number of sensor inputs 1-channel or 2-channel 1

Outputs 10

as NC contact: for signaling function instantaneous contact 0
as NC contact: for signaling function delayed switching 0
as NC contact: safety-related instantaneous contact 0
as NC contact: safety-related delayed switching 0
as NO contact: for signaling function instantaneous contact 0
as NO contact: for signaling function delayed switching 0
as NO contact: safety-related instantaneous contact 0
as NO contact: safety-related delayed switching 0
for signaling function: delayed switching 0
wire length between sensor and electronics evaluation device with Cu 1.5 mm2 and 150 nF/km maximum 4 000 m

Times 10

make time with automatic start: typical 60 ms
make time with automatic start: at DC maximum 60 ms
make time with automatic start after power failure: typical 6 500 ms
make time with automatic start after power failure: maximum 6 500 ms
make time with monitored start: typical 60 ms
make time with monitored start: maximum 60 ms
backslide delay time after opening of the safety circuits typical 40 ms
recovery time after opening of the safety circuits typical 30 ms
pulse duration: of the sensor input minimum 60 ms
pulse duration: of the ON pushbutton input minimum 0.15 s

Control circuit/ Control 3

type of voltage of the control supply voltage DC
control supply voltage at DC rated value 24 V
operating range factor control supply voltage rated value of magnet coil at DC: initial value 0.8

Installation/ mounting/ dimensions 7

mounting position any
fastening method screw and snap-on mounting
height 100 mm
width 17.5 mm
depth 121.6 mm
required spacing: with side-by-side mounting at the side 0 mm
required spacing: for grounded parts at the side 5 mm

Connections/ Terminals 5

type of electrical connection spring-loaded terminal (push-in)
type of connectable conductor cross-sections: solid 1x (0.5 ... 1.5 mm2), 2x (0.5 ... 1.5 mm2)
type of connectable conductor cross-sections: finely stranded with core end processing 1x (0.5 ... 1.0 mm2), 2x (0.5 ... 1.0 mm2)
type of connectable conductor cross-sections: for AWG cables solid 1x (20 ... 16), 2x (20 ... 16)
type of electrical connection plug-in socket No

Logistics 6

Net weight 0.119 kg
Package dimensions 159 × 108 × 35 mm
Country of origin DE
Shipping weight 0.619 kg
Dispatch —
Stock On request

Source: manufacturer data · Last verified: 31 Oct 2026

Documents

Documents for 3SK1220-2AB40 1

Certifications

Certifications and standards

  • IEC 60947-5
Quick answers

Questions about the 3SK1

Which control voltage does 3SK1 need?

The control voltage range of 3SK1 is 24 V.

What is the HS code of 3SK1 for customs?

The tariff (HS) code on file for 3SK1 is 85371098.

What is the EAN of 3SK1?

The EAN (GTIN) of 3SK1 is 4011209913875.

How is 3SK1 delivered, and how fast?

3SK1 ships worldwide by express courier, with tracking. Shipping and import duties calculated at checkout · nothing to pay on delivery.

Reviews

Customer reviews

Series

Siemens 3SK1

Brand
Siemens
Series
3SK1
$160.10 On request
Quote

Get a Quote

3SK1

Genuine parts

Genuine, factory-sealed parts

Siemens · 3SK1220-2AB40

Every part on Stoklink is new, unused and made by the manufacturer named on the page.

Condition
New and unused, in the manufacturer's factory-sealed packaging.
Sourced from
Siemens and its authorised distributors.
Warranty
The manufacturer's warranty applies.
If a part is not genuine
We refund the full amount.

Added to cart Could not add to cart