ATS22C59Q, Altistart 22 Series Soft Starter, 315 kW, 590 A, 230 to 440V AC

Rated current
590 A
Rated operational voltage
230–440 V AC
Motor power
315 kW
Control voltage
110–250 V
Poles
3P
Communication
Modbus RTU
EAN
3606480211300
Description

About the ATS22C59Q

Schneider Electric ATS22 Soft Starter Series – Overview

Schneider Electric ATS22 soft starters are compact and reliable motor starting solutions designed for smooth acceleration and deceleration of asynchronous motors in standard industrial applications. The ATS22 series focuses on reducing mechanical stress, limiting starting current, and simplifying motor starting without advanced digital control requirements. With a proven design and straightforward configuration, ATS22 soft starters are commonly used for pumps, fans, compressors, conveyors, and general-purpose machinery where controlled motor starting is required.


Product Description: ATS22C59Q

The Schneider Altistart ATS22C59Q is a heavy-duty ATS22 series soft starter rated for a nominal operational current of 590 A (at 40 °C) and designed for three‑phase supply voltages in the 195–484 V range (commonly specified as 230–440 V AC, 50/60 Hz). It supports motor power ratings including 160 kW at 230 V (standard connection) and 315 kW at 400 V (standard connection), with additional published power points for triangle/star connections and alternate supply voltages. The unit provides torque control (current-limited starting) to limit inrush and mechanical stress during starts, and includes an internal bypass contactor to reduce heat dissipation and system losses once the motor is running. Integrated motor protection functions such as overload protection are provided, and the starter offers an RS‑485 communications interface for multipoint connection and configuration. Typical applications are pumps, fans, compressors and conveyor drives where controlled, current-limited starting and an internal bypass improve reliability, reduce mechanical wear, and simplify installation and replacement through compatibility with Schneider’s SoMove configuration tools.

Specification

Full specification

73 values · Last verified 30 Oct 2026

Main 14

Range of Product Altistart 22
Product or Component Type Soft starter
Product destination Asynchronous motors
Product Specific Application Pumps and fans
Component name ATS22
Phase 3 phase
[Us] rated supply voltage 230...440 V - 15...10 %
Motor power kW 160 kW 230 V, 315 kW 400 V, 355 kW 440 V
Factory setting current 560 A
Power dissipation in W 251 W for standard applications
Utilisation category AC-53A
Type of start Start with torque control (current limited to 3.5 In)
IcL starter rating 590 A connection in the motor supply line for standard applications
IP Degree of Protection IP00

Complementary 34

Assembly style With heat sink
Function Available Internal bypass
Supply voltage limits 195…484 V
Supply frequency 50...60 Hz - 10...10 %
Network Frequency 45...66 Hz
Device connection To the motor delta terminals, In the motor supply line
[Uc] control circuit voltage 230 V - 15...10 % 50/60 Hz
Control circuit consumption 20 W
Discrete output number 2
Discrete output type Relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O, Relay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O
Minimum switching current 100 mA 12 V DC relay outputs)
Maximum switching current 5 A 250 V AC resistive 1 relay outputs, 5 A 30 V DC resistive 1 relay outputs, 2 A 250 V AC inductive 0.4 20 ms relay outputs, 2 A 30 V DC inductive 7 ms relay outputs
Discrete input number 3
Discrete input type LI1, LI2, LI3) logic, 5 mA 4.3 kOhm
Discrete input voltage 24 V <= 30 V
Discrete input logic Positive logic LI1, LI2, LI3 11 V, >= 5 mA
Output current 0.4...1 Icl adjustable
PTC probe input 750 Ohm
Communication Port Protocol Modbus
Connector Type 1 RJ45
Communication data link Serial
Physical interface RS485 multidrop
Transmission Rate 4800, 9600 or 19200 bps
Installed device 31
Protection type Phase failure line, Thermal protection motor, Thermal protection starter
Marking CE
Type of cooling Forced convection
Operating position Vertical +/- 10 degree
Height 17.9 in (455 mm)
Width 12.0 in (304 mm)
Depth 13.4 in (339.7 mm)
Net Weight 110.2 lb(US) (50 kg)
Motor power range AC-3 110…220 kW 200…240 V 3 phase, 250…500 kW 380…440 V 3 phase
Motor starter type Soft starter

Environment 11

Electromagnetic compatibility Conducted and radiated emissions level A conforming to IEC 60947-4-2, Damped oscillating waves level 3 conforming to IEC 61000-4-12, Electrostatic discharge level 3 conforming to IEC 61000-4-2, Immunity to electrical transients level 4 conforming to IEC 61000-4-4, Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3, Voltage/current impulse level 3 conforming to IEC 61000-4-5
Standards IEC 60947-4-2
Product Certifications UL, CCC, C-tick, CSA, GOST
Vibration resistance 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6, 1.5 mm (f= 2…13 Hz) conforming to IEC 60068-2-6
Shock resistance 15 gn 11 ms IEC 60068-2-27
Noise level 56 dB
Pollution degree Level 2 IEC 60664-1
Relative humidity 0…95 % without condensation or dripping water IEC 60068-2-3
Ambient air temperature for operation 14…104 °F (-10…40 °C) (without derating), 104…140 °F (40…60 °C) (with current derating 2.2 % per °C)
Ambient Air Temperature for Storage -13…158 °F (-25…70 °C)
Operating altitude <= 3280.84 ft (1000 m) without derating, > 3280.84... 1000...< 2000 m) with current derating of 2.2 % per additional 100 m
Show all 73 specifications ↓ Show less ↑14 more values in Identification, Contractual warranty, Logistics.

Identification 8

Part number ATS22C59Q
Brand Schneider Electric
Condition New, factory sealed
Source Schneider Electric and its authorised distributors
Warranty Manufacturer warranty
Lifecycle status Phase-out announced by the manufacturer
Last order date 31 Mar 2027 · as announced for Türkiye, our sourcing market
EAN 3606480211300

Contractual warranty 1

Warranty (in months) 18

Logistics 5

Country of origin CN
Shipping weight 7.0 kg
Ships from Türkiye
Dispatch 11 Nov
Stock Low stock

Source: manufacturer data · Last verified: 30 Oct 2026

Documents

Documents for ATS22C59Q

No documents are on file for this part yet.

Ask us for the datasheet
Certifications

Certifications and standards

  • UL
  • CSA
  • CCC
  • IEC 60947-4-2
Quick answers

Questions about the ATS22C59Q

What is the rated current of ATS22C59Q?

The rated current of ATS22C59Q is 590 A.

Which supply voltage is ATS22C59Q rated for?

The rated operational voltage of ATS22C59Q is 230–440 V AC.

What motor power is ATS22C59Q rated for?

The rated motor power of ATS22C59Q is 315 kW.

Which control voltage does ATS22C59Q need?

The control voltage range of ATS22C59Q is 110–250 V.

What is the HS code of ATS22C59Q for customs?

The tariff (HS) code on file for ATS22C59Q is 853710.

What is the EAN of ATS22C59Q?

The EAN (GTIN) of ATS22C59Q is 3606480211300.

Where does ATS22C59Q ship from, and how fast?

ATS22C59Q ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival. Stock items are dispatched within 1–2 business days.

Guides

Guides for soft starters

All guides for soft starters
Reviews

Customer reviews

Series

Schneider Electric ATS22

Brand
Schneider Electric
Series
ATS22
Series page →
Series

Other series in Schneider Altistart Soft Starters

$6,583.67 Low stock · 11 Nov
Quote

Get a Quote

Genuine parts

Genuine, factory-sealed parts

Schneider Electric · ATS22C59Q

Every part on Stoklink is new, unused and made by the manufacturer named on the page.

Condition
New and unused, in the manufacturer's factory-sealed packaging.
Sourced from
Schneider Electric and its authorised distributors.
Warranty
The manufacturer's warranty applies.
If a part is not genuine
We refund the full amount.

Added to cart Could not add to cart

View cart