How to Select and Size a Soft Starter for a Motor
How to size a soft starter correctly by full-load current, IEC 60947-4-2 duty class, starting torque against the load, control method, wiring topology and...
Last orders until 31 Mar 2027. After that date, supply depends on remaining stock. Date announced by Schneider Electric for Türkiye, where we source this part.
No replacement announced yet. Tell us the application and we will propose an alternative.
Schneider Electric ATS22 soft starters are compact and reliable motor starting solutions designed for smooth acceleration and deceleration of asynchronous motors in standard industrial applications. The ATS22 series focuses on reducing mechanical stress, limiting starting current, and simplifying motor starting without advanced digital control requirements. With a proven design and straightforward configuration, ATS22 soft starters are commonly used for pumps, fans, compressors, conveyors, and general-purpose machinery where controlled motor starting is required.
The Schneider ATS22C14S6U is an Altistart 22 motor soft starter designed for three-phase industrial motor starting where robust current limiting and reduced mechanical stress are required. This SKU is rated for 140 A continuous operation and is suitable for supply voltages from 208 to 600 VAC (50/60 Hz), making it appropriate for 230 V and 400 V systems commonly found in industrial plants. Typical motor compatibility includes up to approximately 75 kW (at 400 V) and around 37 kW (at 230 V), with vendor literature also listing typical horsepower ranges of roughly 40–125 hp depending on voltage. The ATS22C14S6U is intended for standard applications such as pumps, fans and conveyors where controlled starting torque and limited inrush current reduce mechanical wear and electrical network disturbance. Verified model features include an internal bypass to reduce heat loss during run, torque/current-limited starting control for smoother acceleration, and integrated motor overload protection — practical benefits for maintenance teams and procurement looking to replace across common plant voltages without adding external protections.
| Range of Product | Altistart 22 |
|---|---|
| Product or Component Type | Soft starter |
| Product destination | Asynchronous motors |
| Product Specific Application | Pumps and fans |
| Component name | ATS22 |
| Phase | 3 phase |
| [Us] rated supply voltage | 208...600 V - 15...10 % |
| Maximum Horse Power Rating | 100 hp 460 V, 125 hp 575 V, 40 hp 208 V, 50 hp 230 V |
| Factory setting current | 124 A |
| Power dissipation in W | 82 W for standard applications |
| Utilisation category | AC-53A |
| Type of start | Start with torque control (current limited to 3.5 In) |
| IcL starter rating | 140 A connection in the motor supply line for standard applications |
| IP Degree of Protection | IP00 |
| Assembly style | With heat sink |
|---|---|
| Function Available | Internal bypass |
| Supply voltage limits | 177…660 V |
| Supply frequency | 50...60 Hz - 10...10 % |
| Network Frequency | 45...66 Hz |
| Device connection | In the motor supply line |
| [Uc] control circuit voltage | 110 V - 15...10 % 50/60 Hz |
| Control circuit consumption | 20 W |
| Discrete output number | 2 |
| Discrete output type | Relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O, Relay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O |
| Minimum switching current | 100 mA 12 V DC relay outputs) |
| Maximum switching current | 5 A 250 V AC resistive 1 relay outputs, 5 A 30 V DC resistive 1 relay outputs, 2 A 250 V AC inductive 0.4 20 ms relay outputs, 2 A 30 V DC inductive 7 ms relay outputs |
| Discrete input number | 3 |
| Discrete input type | LI1, LI2, LI3) logic, 5 mA 20 kOhm |
| Discrete input voltage | 110 V <= 121 V |
| Discrete input logic | Positive logic LI1, LI2, LI3 79 V, <= 2 mA |
| Output current | 0.4...1 Icl adjustable |
| PTC probe input | 750 Ohm |
| Communication Port Protocol | Modbus |
| Connector Type | 1 RJ45 |
| Communication data link | Serial |
| Physical interface | RS485 multidrop |
| Transmission Rate | 4800, 9600 or 19200 bps |
| Installed device | 31 |
| Protection type | Phase failure line, Thermal protection motor, Thermal protection starter |
| Marking | CE |
| Type of cooling | Forced convection |
| Operating position | Vertical +/- 10 degree |
| Height | 14.02 in (356 mm) |
| Width | 5.9 in (150 mm) |
| Depth | 9.04 in (229.5 mm) |
| Net Weight | 39.7 lb(US) (18 kg) |
| Electromagnetic compatibility | Conducted and radiated emissions level A conforming to IEC 60947-4-2, Damped oscillating waves level 3 conforming to IEC 61000-4-12, Electrostatic discharge level 3 conforming to IEC 61000-4-2, Immunity to electrical transients level 4 conforming to IEC 61000-4-4, Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3, Voltage/current impulse level 3 conforming to IEC 61000-4-5 |
|---|---|
| Standards | IEC 60947-4-2 |
| Product Certifications | C-tick, CCC, CSA, UL, GOST |
| Vibration resistance | 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6, 1.5 mm (f= 2…13 Hz) conforming to IEC 60068-2-6 |
| Shock resistance | 15 gn 11 ms IEC 60068-2-27 |
| Noise level | 56 dB |
| Pollution degree | Level 2 IEC 60664-1 |
| Relative humidity | 0…95 % without condensation or dripping water IEC 60068-2-3 |
| Ambient air temperature for operation | 14…104 °F (-10…40 °C) (without derating), 104…140 °F (40…60 °C) (with current derating 2.2 % per °C) |
| Ambient Air Temperature for Storage | -13…158 °F (-25…70 °C) |
| Operating altitude | <= 3280.84 ft (1000 m) without derating, > 3280.84... 1000...< 2000 m) with current derating of 2.2 % per additional 100 m |
| Part number | ATS22C14S6U |
|---|---|
| Brand | Schneider Electric |
| Condition | New, factory sealed |
| Source | Schneider Electric and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Phase-out announced by the manufacturer |
| Last order date | 31 Mar 2027 · as announced for Türkiye, our sourcing market |
| EAN | 3606480167447 |
| Warranty (in months) | 18 |
|---|
| Unit Type of Package 1 | PCE |
|---|---|
| Nbr. of units in pkg. | 1 |
| Package 1 Height | 9.8 in (25.0 cm) |
| Package 1 Width | 13.0 in (33.0 cm) |
| Package 1 Length | 16.1 in (41.0 cm) |
| Package weight(Lbs) | 29.132 lb(US) (13.214 kg) |
| Unit Type of Package 2 | P06 |
| Number of Units in Package 2 | 4 |
| Package 2 Height | 28.9 in (73.5 cm) |
| Package 2 Width | 31.5 in (80.0 cm) |
| Package 2 Length | 23.6 in (60.0 cm) |
| Package 2 Weight | 145.188 lb(US) (65.856 kg) |
| Shipping weight | 18.0 kg |
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 30 Oct 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated current of ATS22C14S6U is 10 A.
The rated operational voltage of ATS22C14S6U is 230–600 V AC.
The rated motor power of ATS22C14S6U is 75 kW.
The control voltage range of ATS22C14S6U is 110–250 V.
The tariff (HS) code on file for ATS22C14S6U is 853710.
The EAN (GTIN) of ATS22C14S6U is 3606480167447.
ATS22C14S6U ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.
How to size a soft starter correctly by full-load current, IEC 60947-4-2 duty class, starting torque against the load, control method, wiring topology and...
A side-by-side comparison of soft starters and autotransformer (Korndorfer) starters covering torque, supply-side current, transition type, maintenance, cost, and load fit.
Explore the different types of soft starters, from analog to digital and solid-state models, with key features for industrial motor control. Shop at Stoklink.