ABB AF Series vs Schneider TeSys Contactor: Full Technical Comparison
ABB AF contactor vs Schneider TeSys: full technical comparison of coil tech, ratings, coordination, and selection for IEC motor starters. Shop at Stoklink.
The ABB AF370-30-11-13 (SKU: 1SFL607002R1311) is a 3-pole AC power contactor rated at 600 A AC-1 and 1000 V IEC, delivering 200 kW at 400 V AC-3 for heavy-duty industrial switching applications. Part of ABB's trusted AF series, the AF370-30-11-13 is engineered for demanding control panel and motor switching duties where reliability, global certification, and high current capacity are non-negotiable. With a UL general-use rating of 520 A at 600 V and 300 hp at 480 V, this contactor bridges IEC and UL environments seamlessly.
| Product Net Width | 140 mm |
|---|---|
| Product Net Depth / Length | 180 mm |
| Product Net Height | 225 mm |
| Product Net Weight | 3.9 kg |
| Number of Main Contacts NO | 3 |
|---|---|
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 1 |
| Number of Auxiliary Contacts NC | 1 |
| Number of Poles | 3P |
| Rated Operational Voltage | Main Circuit 1000 V |
| Rated Frequency (f) | Main Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 600 A |
| Rated Operational Current AC-1 (Ie) | (1000 V) 40 °C 400 A, (1000 V) 55 °C 350 A, (1000 V) 60 °C 350 A, (1000 V) 70 °C 290 A, (690 V) 40 °C 600 A, (690 V) 55 °C 500 A, (690 V) 70 °C 400 A |
| Rated Operational Current AC-3 (Ie) | (415 V) 55 °C 370 A, (440 V) 55 °C 370 A, (500 V) 55 °C 350 A, (690 V) 55 °C 315 A, (1000 V) 55 °C 141 A, (380 / 400 V) 55 °C 370 A, (220 / 230 / 240 V) 55 °C 370 A |
| Rated Operational Current DC-1 (Ie) | (110 V) 2 Poles in Series, 40 °C 450 A, (220 V) 3 Poles in Series, 40 °C 450 A |
| Rated Operational Current DC-3 (Ie) | (110 V) 2 Poles in Series, 40 °C 450 A, (220 V) 3 Poles in Series, 40 °C 450 A |
| Rated Operational Current DC-5 (Ie) | (110 V) 2 Poles in Series, 40 °C 450 A, (220 V) 3 Poles in Series, 40 °C 450 A |
| Rated Operational Power AC-3 (Pe) | (415 V) 200 kW, (440 V) 200 kW, (500 V) 250 kW, (690 V) 315 kW, (1000 V) 200 kW, (380 / 400 V) 200 kW, (220 / 230 / 240 V) 110 kW |
| Rated Breaking Capacity AC-3 | 8 x Ie AC-3 |
| Rated Making Capacity AC-3 | 10 x Ie AC-3 |
| Short-Circuit Protective Devices | gG Type Fuses 630 A |
| Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2960 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 600 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 1208 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3700 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1709 A |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 5000 A, cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 4000 A |
| Rated Insulation Voltage (Ui) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V, acc. to UL/CSA 1000 V |
| Rated Impulse Withstand Voltage (Uimp) | Main Circuit 8 kV |
| Maximum Electrical Switching Frequency | (AC-1) 300 cycles per hour, (AC-2 / AC-4) 150 cycles per hour, (AC-3) 300 cycles per hour |
| Mechanical Durability | 5 million |
| Maximum Mechanical Switching Frequency | 300 cycles per hour |
| Coil Operating Limits | (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) |
| Rated Control Circuit Voltage (Uc) | 50 Hz 100 ... 250 V, 60 Hz 100 ... 250 V, DC Operation 100 ... 250 V |
| Coil Consumption | Holding at Max. Rated Control Circuit Voltage 50 Hz 33.6 V·A, Holding at Max. Rated Control Circuit Voltage 50 Hz 4.3 W, Holding at Max. Rated Control Circuit Voltage 60 Hz 33.6 V·A, Holding at Max. Rated Control Circuit Voltage 60 Hz 4.3 W, Holding at Max. Rated Control Circuit Voltage DC 4.4 W, Pull-in at Max. Rated Control Circuit Voltage 50 Hz 662 V·A, Pull-in at Max. Rated Control Circuit Voltage 60 Hz 662 V·A, Pull-in at Max. Rated Control Circuit Voltage DC 830 V·A, Pull-in at Max. Rated Control Circuit Voltage DC 830 W |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 46 W, at Rated Operating Conditions AC-3 per Pole 17 W |
| Operate Time | Between Coil De-energization and NO Contact Opening 37 ... 47 ms, Between Coil Energization and NO Contact Closing 25 ... 55 ms |
| Connecting Capacity Main Circuit | Flexible 2 x 70 ... 185 mm², Rigid Al-Cable 1 x 185 ... 240 mm², Rigid Cu-Cable 2 x 70 ... 185 mm² |
| Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 2x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm², Flexible 2x0.75 ... 2.5 mm², Solid 2 x 1 ... 4 mm², Stranded 1 x 1 .... 4 mm² |
| Connecting Capacity | Flexible 2 x 70 ... 185 mm², Rigid Al-Cable 1 x 185 ... 240 mm², Rigid Cu-Cable 2 x 70 ... 185 mm² |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00 |
| Tightening Torque | Cable Lug 28 N·m, Main Circuit 22 ... 43 N·m |
| Terminal Type | Main Circuit: Bars |
| Product Name | Block Contactor |
| Maximum Operating Voltage UL/CSA | Main Circuit 1000 V |
|---|---|
| General Use Rating UL/CSA | (1000 V AC) 400 A, (600 V AC) 520 A |
| Horsepower Rating UL/CSA | (200 V AC) Three Phase 125 hp, (208 V AC) Three Phase 125 hp, (220 ... 240 V AC) Three Phase 150, (440 ... 480 V AC) Three Phase 300 hp, (550 ... 600 V AC) Three Phase 350 hp |
| Full Load Amps Motor Use | (440 ... 480 V AC) Three Phase 361 A, (550 ... 600 V AC) Three Phase 336 A |
| Part number | 1SFL607002R1311 |
|---|---|
| Type designation | AF370-30-11-13 |
| Brand | ABB |
| Condition | New, factory sealed |
| Source | ABB and its authorised distributors |
| Warranty | Manufacturer warranty |
| EAN | 7320500481899 |
| eCl@ss | 27371003 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Ambient Air Temperature | Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C, Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C, Close to Contactor for Storage -40 ... 70 °C |
|---|---|
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
| REACH Declaration | 2CMT2021-006202 |
|---|---|
| RoHS Declaration | 2CMT2021-006277 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Simplified SCIP | 0fa2ce0e-00cb-4734-beb0-e900a8c2a4fa Germany, 15739afa-43de-431d-9dd7-c3e484a6095c Norway, 193c2cd9-89a0-4266-bdbe-f72f0c6a5037 Romania, 2510c209-3698-4dd1-81d3-ce1c38fd24fe Denmark, 270015c8-1b62-4754-816b-a4fc36dc94c0 Hungary, 2f1a1dff-1c9e-479f-8bc2-d18106449c29 Sweden, 33493f4e-0c3a-421e-8756-6875bb0e8209 Estonia, 3ee0c624-f396-4a2d-8400-730c1b4ddbf1 Finland, 4838a592-371f-428f-950f-57f69835e1bd Netherlands, 4b6b6cec-3a99-4a59-aefc-5a5f4d9ad62f Bulgaria, 4ef5b1ac-27a2-45fa-accd-6a7448994fb0 Czechia, 65e08fab-28c3-45dd-96c7-8692709385b8 France, 99878b44-9b02-4296-ad82-e840da891aa5 Greece, 9e5462fc-5af5-441a-9c4d-a6e84e35b771 Belgium, ad8bf09b-aeb3-4c85-995c-394237ae672e Poland, ba8b4775-54dd-4a95-93e8-692c8bc411a8 Spain, c6f9b3c6-0cde-4831-a366-40f17ea7766b Croatia, ccb5a327-8e1d-4213-8175-bf886791506a Portugal, e671c1bd-27e0-4ed0-b59c-177595d64cee China |
| Toxic Substances Control Act - TSCA | 2CMT2023-006525 |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| ETIM 7 | EC000066 - Power contactor, AC switching |
|---|---|
| eClass | V11.0 : 27371003 |
| UNSPSC | 39121529 |
| E-Number (Sweden) | 3210171 |
| Package Level 1 Units | box 1 piece |
|---|---|
| Package Level 1 Width | 263 mm |
| Package Level 1 Depth / Length | 203 mm |
| Package Level 1 Height | 289 mm |
| Package Level 1 Gross Weight | 4.6 kg |
| Package Level 1 EAN | 7320500481899 |
| Shipping weight | 4.6 kg |
| Ships from | Türkiye |
| Dispatch | 9 Nov |
| Stock | In stock |
Source: manufacturer data · Last verified: 30 Oct 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated current of AF370-30-11-13 is 600 A.
The rated operational voltage of AF370-30-11-13 is 1000 V AC.
The rated motor power of AF370-30-11-13 is 200 kW.
The tariff (HS) code on file for AF370-30-11-13 is 85364900.
The EAN (GTIN) of AF370-30-11-13 is 7320500481899.
AF370-30-11-13 ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival. Stock items are dispatched within 1–2 business days.
ABB AF contactor vs Schneider TeSys: full technical comparison of coil tech, ratings, coordination, and selection for IEC motor starters. Shop at Stoklink.
AC-1 and AC-6a contactors for data center PDU and UPS systems: sizing, harmonic derating, coil selection, and endurance guidance for engineers. Shop at Stoklink.
Compare AC3 rating IEC contactors versus NEMA size codes, with cross-reference tables, derating formulas, and selection tips for engineers. Shop at Stoklink.