Part number
1SFL607002R1311
Model no
AF370-30-11-13
$996.16 In stock · 12 Dispatch Planned dispatch date. We aim to ship within 1 business day. Depending on warehouse workload it can take 2–3 business days. · From Türkiye

ABB 1SFL607002R1311 AF370-30-11-13 3-Pole 600A 1000V AC-1 200kW Power Contactor AC Switching

Rated current
600 A
Rated operational voltage
1000 V AC
Motor power
200 kW
Poles
3P
EAN
7320500481899
Description

About the AF370-30-11-13

The ABB AF370-30-11-13 (SKU: 1SFL607002R1311) is a 3-pole AC power contactor rated at 600 A AC-1 and 1000 V IEC, delivering 200 kW at 400 V AC-3 for heavy-duty industrial switching applications. Part of ABB's trusted AF series, the AF370-30-11-13 is engineered for demanding control panel and motor switching duties where reliability, global certification, and high current capacity are non-negotiable. With a UL general-use rating of 520 A at 600 V and 300 hp at 480 V, this contactor bridges IEC and UL environments seamlessly.

Certifications & Standards

  • CE: Conforms to European Union directives for electrical equipment safety and electromagnetic compatibility
  • UKCA: UK Conformity Assessed — compliant for Great Britain market requirements
  • cULus: Listed by Underwriters Laboratories for both US (UL) and Canadian (cUL) markets; UL File E36588
  • CCC (CQC): China Compulsory Certification for the Chinese market
  • CCS: China Classification Society approval for marine applications
  • DNV: Det Norske Veritas type approval for offshore and marine installations
  • KC EMC: Korean Certification for electromagnetic compatibility
  • LR (Lloyd's Register): Type approved by Lloyd's Register for marine and offshore use
  • PRS: Polski Rejestr Statków — Polish Ship Register approval
  • RINA: Registro Italiano Navale approval for marine applications
  • CB (SE-89316): International CB Scheme certificate for global market acceptance
  • UL E36588: UL file number confirming North American listing
  • IEC 60947-4: International standard for AC contactors and motor-starters
  • IEC 60947-1: General rules for low-voltage switchgear and controlgear
  • IEC 60529: Degrees of protection provided by enclosures (IP rating standard)
  • EN 45555: General methods for the assessment of the ability to recover materials and energy from electrical and electronic equipment
  • EN 45555-76: Specific product family requirements under EN 45555
  • CSA: Canadian Standards Association certification
  • REACH: Compliant with EU REACH regulation on chemical substances
  • RoHS: Restriction of Hazardous Substances — compliant with EU RoHS directive
  • WEEE: Compliant with EU Waste Electrical and Electronic Equipment directive

Applications & Use Cases

  • Heavy-duty AC motor switching in industrial drives and compressor systems
  • Main and distribution panel switching for large loads up to 600 A
  • Marine and offshore power distribution (DNV, LR, RINA, CCS, PRS approved)
  • Industrial automation and process control panels requiring IEC 60947-4 compliance
  • Global OEM installations requiring simultaneous IEC and UL/CSA market coverage
Specification

Full specification

77 values · Last verified 30 Oct 2026

Dimensions 4

Product Net Width 140 mm
Product Net Depth / Length 180 mm
Product Net Height 225 mm
Product Net Weight 3.9 kg

Technical 36

Number of Main Contacts NO 3
Number of Main Contacts NC 0
Number of Auxiliary Contacts NO 1
Number of Auxiliary Contacts NC 1
Number of Poles 3P
Rated Operational Voltage Main Circuit 1000 V
Rated Frequency (f) Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith) acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 600 A
Rated Operational Current AC-1 (Ie) (1000 V) 40 °C 400 A, (1000 V) 55 °C 350 A, (1000 V) 60 °C 350 A, (1000 V) 70 °C 290 A, (690 V) 40 °C 600 A, (690 V) 55 °C 500 A, (690 V) 70 °C 400 A
Rated Operational Current AC-3 (Ie) (415 V) 55 °C 370 A, (440 V) 55 °C 370 A, (500 V) 55 °C 350 A, (690 V) 55 °C 315 A, (1000 V) 55 °C 141 A, (380 / 400 V) 55 °C 370 A, (220 / 230 / 240 V) 55 °C 370 A
Rated Operational Current DC-1 (Ie) (110 V) 2 Poles in Series, 40 °C 450 A, (220 V) 3 Poles in Series, 40 °C 450 A
Rated Operational Current DC-3 (Ie) (110 V) 2 Poles in Series, 40 °C 450 A, (220 V) 3 Poles in Series, 40 °C 450 A
Rated Operational Current DC-5 (Ie) (110 V) 2 Poles in Series, 40 °C 450 A, (220 V) 3 Poles in Series, 40 °C 450 A
Rated Operational Power AC-3 (Pe) (415 V) 200 kW, (440 V) 200 kW, (500 V) 250 kW, (690 V) 315 kW, (1000 V) 200 kW, (380 / 400 V) 200 kW, (220 / 230 / 240 V) 110 kW
Rated Breaking Capacity AC-3 8 x Ie AC-3
Rated Making Capacity AC-3 10 x Ie AC-3
Short-Circuit Protective Devices gG Type Fuses 630 A
Rated Short-time Withstand Current Low Voltage (Icw) at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2960 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 600 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 1208 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3700 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1709 A
Maximum Breaking Capacity cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 5000 A, cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 4000 A
Rated Insulation Voltage (Ui) acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V, acc. to UL/CSA 1000 V
Rated Impulse Withstand Voltage (Uimp) Main Circuit 8 kV
Maximum Electrical Switching Frequency (AC-1) 300 cycles per hour, (AC-2 / AC-4) 150 cycles per hour, (AC-3) 300 cycles per hour
Mechanical Durability 5 million
Maximum Mechanical Switching Frequency 300 cycles per hour
Coil Operating Limits (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc) 50 Hz 100 ... 250 V, 60 Hz 100 ... 250 V, DC Operation 100 ... 250 V
Coil Consumption Holding at Max. Rated Control Circuit Voltage 50 Hz 33.6 V·A, Holding at Max. Rated Control Circuit Voltage 50 Hz 4.3 W, Holding at Max. Rated Control Circuit Voltage 60 Hz 33.6 V·A, Holding at Max. Rated Control Circuit Voltage 60 Hz 4.3 W, Holding at Max. Rated Control Circuit Voltage DC 4.4 W, Pull-in at Max. Rated Control Circuit Voltage 50 Hz 662 V·A, Pull-in at Max. Rated Control Circuit Voltage 60 Hz 662 V·A, Pull-in at Max. Rated Control Circuit Voltage DC 830 V·A, Pull-in at Max. Rated Control Circuit Voltage DC 830 W
Power Loss at Rated Operating Conditions AC-1 per Pole 46 W, at Rated Operating Conditions AC-3 per Pole 17 W
Operate Time Between Coil De-energization and NO Contact Opening 37 ... 47 ms, Between Coil Energization and NO Contact Closing 25 ... 55 ms
Connecting Capacity Main Circuit Flexible 2 x 70 ... 185 mm², Rigid Al-Cable 1 x 185 ... 240 mm², Rigid Cu-Cable 2 x 70 ... 185 mm²
Connecting Capacity Auxiliary Circuit Flexible with Ferrule 2x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm², Flexible 2x0.75 ... 2.5 mm², Solid 2 x 1 ... 4 mm², Stranded 1 x 1 .... 4 mm²
Connecting Capacity Flexible 2 x 70 ... 185 mm², Rigid Al-Cable 1 x 185 ... 240 mm², Rigid Cu-Cable 2 x 70 ... 185 mm²
Degree of Protection acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Tightening Torque Cable Lug 28 N·m, Main Circuit 22 ... 43 N·m
Terminal Type Main Circuit: Bars
Product Name Block Contactor

Technical UL/CSA 4

Maximum Operating Voltage UL/CSA Main Circuit 1000 V
General Use Rating UL/CSA (1000 V AC) 400 A, (600 V AC) 520 A
Horsepower Rating UL/CSA (200 V AC) Three Phase 125 hp, (208 V AC) Three Phase 125 hp, (220 ... 240 V AC) Three Phase 150, (440 ... 480 V AC) Three Phase 300 hp, (550 ... 600 V AC) Three Phase 350 hp
Full Load Amps Motor Use (440 ... 480 V AC) Three Phase 361 A, (550 ... 600 V AC) Three Phase 336 A
Show all 77 specifications ↓ Show less ↑33 more values in Identification, Environmental, Material Compliance, External Classifications and Standards, Logistics.

Identification 10

Part number 1SFL607002R1311
Type designation AF370-30-11-13
Brand ABB
Condition New, factory sealed
Source ABB and its authorised distributors
Warranty Manufacturer warranty
EAN 7320500481899
eCl@ss 27371003
Minimum Order Quantity 1 piece
Customs Tariff Number 85364900

Environmental 2

Ambient Air Temperature Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C, Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C, Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible Without Derating 3000 m

Material Compliance 7

REACH Declaration 2CMT2021-006202
RoHS Declaration 2CMT2021-006277
RoHS Information Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Simplified SCIP 0fa2ce0e-00cb-4734-beb0-e900a8c2a4fa Germany, 15739afa-43de-431d-9dd7-c3e484a6095c Norway, 193c2cd9-89a0-4266-bdbe-f72f0c6a5037 Romania, 2510c209-3698-4dd1-81d3-ce1c38fd24fe Denmark, 270015c8-1b62-4754-816b-a4fc36dc94c0 Hungary, 2f1a1dff-1c9e-479f-8bc2-d18106449c29 Sweden, 33493f4e-0c3a-421e-8756-6875bb0e8209 Estonia, 3ee0c624-f396-4a2d-8400-730c1b4ddbf1 Finland, 4838a592-371f-428f-950f-57f69835e1bd Netherlands, 4b6b6cec-3a99-4a59-aefc-5a5f4d9ad62f Bulgaria, 4ef5b1ac-27a2-45fa-accd-6a7448994fb0 Czechia, 65e08fab-28c3-45dd-96c7-8692709385b8 France, 99878b44-9b02-4296-ad82-e840da891aa5 Greece, 9e5462fc-5af5-441a-9c4d-a6e84e35b771 Belgium, ad8bf09b-aeb3-4c85-995c-394237ae672e Poland, ba8b4775-54dd-4a95-93e8-692c8bc411a8 Spain, c6f9b3c6-0cde-4831-a366-40f17ea7766b Croatia, ccb5a327-8e1d-4213-8175-bf886791506a Portugal, e671c1bd-27e0-4ed0-b59c-177595d64cee China
Toxic Substances Control Act - TSCA 2CMT2023-006525
WEEE B2C / B2B Business To Business
WEEE Category 5. Small Equipment (No External Dimension More Than 50 cm)

External Classifications and Standards 4

ETIM 7 EC000066 - Power contactor, AC switching
eClass V11.0 : 27371003
UNSPSC 39121529
E-Number (Sweden) 3210171

Logistics 10

Package Level 1 Units box 1 piece
Package Level 1 Width 263 mm
Package Level 1 Depth / Length 203 mm
Package Level 1 Height 289 mm
Package Level 1 Gross Weight 4.6 kg
Package Level 1 EAN 7320500481899
Shipping weight 4.6 kg
Ships from Türkiye
Dispatch 9 Nov
Stock In stock

Source: manufacturer data · Last verified: 30 Oct 2026

Documents

Documents for 1SFL607002R1311

No documents are on file for this part yet.

Ask us for the datasheet
Certifications

Certifications and standards

  • CE
  • DNV
  • RoHS
Quick answers

Questions about the AF370-30-11-13

What is the rated current of AF370-30-11-13?

The rated current of AF370-30-11-13 is 600 A.

Which supply voltage is AF370-30-11-13 rated for?

The rated operational voltage of AF370-30-11-13 is 1000 V AC.

What motor power is AF370-30-11-13 rated for?

The rated motor power of AF370-30-11-13 is 200 kW.

What is the HS code of AF370-30-11-13 for customs?

The tariff (HS) code on file for AF370-30-11-13 is 85364900.

What is the EAN of AF370-30-11-13?

The EAN (GTIN) of AF370-30-11-13 is 7320500481899.

Where does AF370-30-11-13 ship from, and how fast?

AF370-30-11-13 ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival. Stock items are dispatched within 1–2 business days.

Guides

Guides for contactors

All guides for contactors
Reviews

Customer reviews

Series

ABB ABB AF

Brand
ABB
Series
ABB AF
Series page →
Series

Other series in Contactors

$996.16 In stock · 9 Nov
Quote

Get a Quote

AF370-30-11-13

Genuine parts

Genuine, factory-sealed parts

ABB · 1SFL607002R1311

Every part on Stoklink is new, unused and made by the manufacturer named on the page.

Condition
New and unused, in the manufacturer's factory-sealed packaging.
Sourced from
ABB and its authorised distributors.
Warranty
The manufacturer's warranty applies.
If a part is not genuine
We refund the full amount.

Added to cart Could not add to cart

View cart