Filter

Schneider TeSys Deca Contactors

Filter
Showing 1 - 205 of 205 items

Schneider Electric LC1D09E7 TeSys Deca 3-Pole 9A 480V AC Coil 5HP Power Contactor

Reference No: LC1D09E7
Rated Current (A): 9
Rated Voltage (VAC): 480 V AC
Number of Poles: 3P
58 pcs in stock
$31.61

Schneider Electric LC1D09D7 TeSys Deca Contactor 3P 3NO AC-3 9 A 42 V AC Coil Contactor

Reference No: LC1D09D7
Rated Current (A): 9
Rated Voltage (VAC): 42 V AC
Number of Poles: 3P
0 pcs in stock
$25.55

Schneider Electric LC1D09BL TeSys Deca 3-Pole 9A 480V AC 100kA Contactor

Reference No: LC1D09BL
Rated Current (A): 9
Rated Voltage (VAC): 480 V AC
Number of Poles: 3P
100 pcs in stock
$39.63

Schneider Electric LC1D09BD TeSys D 3P 9A 4kW 24VDC Coil AC-3 Power Contactor

Reference No: LC1D09BD
Rated Current (A): 9
Rated Voltage (VAC): <=690V AC, <=300V DC
Number of Poles: 3P
100 pcs in stock
$45.95

Schneider Electric LC1D09B7 TeSys Deca 3-Pole 9A 480VAC Coil 24V AC-3 Motor Contactor

Reference No: LC1D09B7
Rated Current (A): 9
Rated Voltage (VAC): 480 V AC
Number of Poles: 3P
100 pcs in stock
$31.61

Schneider Electric TeSys Deca contactors are modular power contactors for motor control and load switching. Stoklink offers over 200 TeSys Deca items from 9 A to 200 A and 4 kW to 75 kW, in 3 pole and 4 pole versions. We ship worldwide from Turkey and quote project volumes on request.

What's in this range

  • LC1D three-pole contactors, rated for AC-3 duty.
  • Four-pole versions for AC-1 switching of four-wire loads.
  • A wide choice of AC and DC coil voltages, set by the code at the end of the part number.
  • Models with snap-in or EverLink terminals, as listed in the titles.

How to choose

  • Pick the frame by AC-3 current at your voltage. The digits after LC1D give the rated current.
  • Read the coil code at the end of the part number. It sets voltage and AC or DC.
  • Choose 3P for motors and 4P for neutral switching.
  • Plan add-on auxiliary blocks and overload relays from the same series.

FAQ

How do I read an LC1D part number?

LC1D is the series, the next digits give the AC-3 current, and the letters at the end give the coil voltage code.

Can I swap the coil on a TeSys Deca contactor?

Coils are replaceable within a frame. Use the coil reference listed for that exact contactor size.

Do you ship contactors outside Turkey?

Yes. Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so send the part numbers for a quote. Project quantities are quoted on request.