Categories
No result found for your search.
Need help? Contact us
+90 542 203 61013
info@stoklink.com
Your cart is empty
- Home
- All Collections
- Schneider EasyPact CVS MCCBs
Filter
Schneider EasyPact CVS MCCBs
Schneider Electric LV510330 EasyPact CVS100F 3P 16 A 36 kA TM-D Fixed Moulded Case Circuit Breaker
Schneider Electric LV510317 CVS100B EasyPact CVS 4P 100A 25kA Fixed Moulded Case Circuit Breaker
Schneider Electric LV510316 CVS100B EasyPact CVS 4P 80A Moulded Case Circuit Breaker
Schneider Electric LV510315 CVS100B EasyPact CVS 4P 63A 25kA Moulded Case Circuit Breaker
Schneider Electric LV510314 CVS100B EasyPact CVS 4P 50A Moulded Case Circuit Breaker
Schneider Electric LV510313 CVS100B EasyPact CVS 4P 40A Moulded Case Circuit Breaker
Schneider Electric LV510312 EasyPact CVS100B 4P 32 A 25 kA TM-D Fixed Moulded Case Circuit Breaker
Schneider Electric LV510310 EasyPact CVS100B 4P 16 A 25 kA TM-D Fixed Moulded Case Circuit Breaker
Schneider Electric LV510307 CVS100B EasyPact CVS 3P 100A 25kA Moulded Case Circuit Breaker
Schneider Electric LV510306 CVS100B EasyPact CVS 3P 80A 25kA Moulded Case Circuit Breaker
Schneider Electric LV510305 CVS100B EasyPact CVS 3P 63A 25kA Moulded Case Circuit Breaker
Schneider Electric LV510304 CVS100B 3P 50A 25kA 415V Moulded Case Circuit Breaker
Schneider Electric LV510303 CVS100B 3P 40A 25kA 415VAC Moulded Case Circuit Breaker
Schneider Electric LV510302 CVS100B EasyPact CVS 3P 32A Moulded Case Circuit Breaker
Schneider Electric LV510301 EasyPact CVS100B 3P 25 A 25 kA TM-D Fixed Moulded Case Circuit Breaker
Schneider Electric LV510300 EasyPact CVS100B 3P 16 A 25 kA TM-D Fixed Moulded Case Circuit Breaker
Schneider Electric EasyPact CVS MCCBs are molded case circuit breakers for building and industrial distribution. The range covers 3-pole and 4-pole breakers in CVS100, CVS160, CVS250, CVS400 and CVS630 frames, with more than 130 products. Stoklink ships worldwide from Turkey and quotes volumes on request.
What's in this range
- CVS100 to CVS630 frames with thermal-magnetic trip units.
- MA magnetic-only units for motor circuits.
- ETS electronic trip units on larger frames.
- Related: Schneider ComPacT NSX MCCBs.
How to choose
- Frame size sets the current range.
- Breaking capacity class (B, F, N, H) must exceed the fault level.
- Magnetic-only MA units need a separate thermal relay in motor circuits.
FAQ
What is an MA trip unit?
It is a magnetic-only unit that protects against short circuit. Overload protection comes from a separate thermal relay.
What does the number after CVS mean?
It is the frame rating in amperes, for example CVS100 or CVS400.
Do you ship EasyPact CVS breakers abroad?
Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so request a quote with your part numbers and quantities.