- Home
- All Collections
- Motor Control & Protection
Motor Control & Protection
Motor Control & Protection Categories
Motor Control & Protection
Siemens 3RT1467-6AP36 3RT1 500A 3P 690V Contactor
Siemens 3RT1466-6AP36 3RT1 400A 3P 690V Contactor
Siemens 3RT1456-6AP36 3RT1 275A 3P 690V Contactor
Siemens 3RT1375-6AP36 3RT1 525A 4P 400V Contactor
Siemens 3RT1374-6AP36 3RT1 500A 4P 400V Contactor
Siemens 3RT1373-6AP36 3RT1 400A 4P 400V Contactor
Siemens 3RT1364-6AP36 3RT1 350A 4P 400V Contactor
Siemens 3RT1363-6AP36 3RT1 275A 4P 400V Contactor
Siemens 3RT1355-6AP36 3RT1 200A 4P 400V Contactor
Siemens 3RT1076-6AP36 3RT1 500A 3P 400V Contactor
Siemens 3RT1075-6AP36 3RT1 400A 3P 400V Contactor
Siemens 3RT1066-6AP36 3RT1 300A 3P 400V Contactor
Siemens 3RT1065-6AP36 3RT1 265A 3P 400V Contactor
Siemens 3RT1064-6AP36 3RT1 225A 3P 400V Contactor
Siemens 3RT1056-6AP36 3RT1 185A 3P 400V Contactor
Siemens 3RT1055-6AP36 3RT1 150A 3P 400V Contactor
Siemens 3RT1054-1AP36 3RT1 115A 3P 400V Contactor
Siemens 3RV2011-1AA10 SIRIUS 3RV2 1.1-1.6A 100kA Motor Starter Protector Circuit Breaker S00
Siemens 3RT2015-1AP01 SIRIUS 3-Pole 3kW AC 230V Coil 1NO Contactor
Siemens 3RV2021-4DA10 SIRIUS 3RV2 25A 55kA Motor Starter Protector Circuit Breaker Size S0
Motor control and protection equipment from ABB, Siemens and Schneider Electric covers everything between the supply and the motor shaft. The range spans contactors, overload relays, motor protection circuit breakers, starters, soft starters, variable frequency drives, servo systems and industrial motors, with rated currents from 0.1 A to 2,650 A and power up to 800 kW. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- Contactors – switching devices for motor and load circuits, mostly 3-pole
- Thermal Overload Relays – bimetal and electronic relays for motor overload protection
- Motor Protection Circuit Breakers (MPCB) – short-circuit and overload protection in one device
- Motor Starters & Motor Management – starter combinations and motor controllers such as TeSys U and SIRIUS 3RK
- Soft Starters – controlled ramp-up for 3-phase motors
- Variable Frequency Drives (VFD) – speed control with ABB ACS, Schneider Altivar and Siemens SINAMICS
- Servo Drives & Motion Control – servo motors, drives, controllers and cables
- Industrial Motors – SIMOTICS asynchronous motors
How to choose
- Motor power and rated current at the supply voltage. Size the starter or drive for the nameplate current, not just the kW value.
- Starting method: direct on line, soft start or variable speed. This decides whether you need a contactor, a soft starter or a VFD.
- Duty class, for example AC-3 for squirrel-cage motors under IEC 60947-4-1.
- Protection split: overload relay plus fuses or MCB, or a single MPCB.
- Control interface: coil voltage, fieldbus such as PROFINET, and mounting.
FAQ
What is the difference between a soft starter and a VFD?
A soft starter limits inrush current during start and stop at fixed supply frequency. A VFD changes the output frequency, so it also controls speed while running.
Do I need a contactor and an overload relay, or an MPCB?
An MPCB combines short-circuit and overload protection and works with a contactor. The separate route uses a fuse or MCB, a contactor and an overload relay. Choose by space, coordination type and rating.
Can you ship motor control products outside Turkey?
Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, and project quantities are quoted on request.