Siemens 3RT2015-1BB41 3RT2 7A 3P 400V Contactor

Reference No: 3RT2015-1BB41
Catalog No: 3RT2015-1BB41
Rated Current (A): 7
Rated Voltage (VAC): 400 V
Number of Poles: 3P
2412 pcs in stock
$28.23

Siemens 3RT2015-1AP02 3RT2 7A 3P 400V Contactor

Reference No: 3RT2015-1AP02
Catalog No: 3RT2015-1AP02
Rated Current (A): 7
Rated Voltage (VAC): 400 V
Number of Poles: 3P
953 pcs in stock
$25.23

Siemens 3RT1976-6A 3RT1 Contactor

Reference No: 3RT1976-6A
Catalog No: 3RT1976-6A
16 pcs in stock
$736.78

Siemens 3RT1975-6A 3RT1 Contactor

Reference No: 3RT1975-6A
Catalog No: 3RT1975-6A
11 pcs in stock
$628.76

Siemens 3RT1975-5AP31 3RT1 240V Contactor

Reference No: 3RT1975-5AP31
Catalog No: 3RT1975-5AP31
Rated Voltage (VAC): 240 V
3 pcs in stock
$116.50

Siemens 3RT1966-6A 3RT1 Contactor

Reference No: 3RT1966-6A
Catalog No: 3RT1966-6A
6 pcs in stock
$678.95

Siemens 3RT1965-6A 3RT1 Contactor

Reference No: 3RT1965-6A
Catalog No: 3RT1965-6A
32 pcs in stock
$449.21

Siemens 3RT1965-5AP31 3RT1 240V Contactor

Reference No: 3RT1965-5AP31
Catalog No: 3RT1965-5AP31
Rated Voltage (VAC): 240 V
0 pcs in stock
$133.71

Siemens 3RT1964-6A 3RT1 Contactor

Reference No: 3RT1964-6A
Catalog No: 3RT1964-6A
18 pcs in stock
$378.66

Siemens 3RT1956-6A 3RT1 Contactor

Reference No: 3RT1956-6A
Catalog No: 3RT1956-6A
21 pcs in stock
$291.32

Siemens 3RT1955-6A 3RT1 Contactor

Reference No: 3RT1955-6A
Catalog No: 3RT1955-6A
20 pcs in stock
$236.53

Siemens 3RT1955-5AP31 3RT1 240V Contactor

Reference No: 3RT1955-5AP31
Catalog No: 3RT1955-5AP31
Rated Voltage (VAC): 240 V
0 pcs in stock
$88.61

Siemens 3RT1954-6A 3RT1 Contactor

Reference No: 3RT1954-6A
Catalog No: 3RT1954-6A
20 pcs in stock
$181.11

Siemens 3RT1487-6AP36 3RT1 2650A 3P 690V Contactor

Reference No: 3RT1487-6AP36
Catalog No: 3RT1487-6AP36
Rated Current (A): 2650
Rated Voltage (VAC): 690 V
Number of Poles: 3P
0 pcs in stock
$11,958.52

Siemens 3RT1486-6AP36 3RT1 2100A 3P 690V Contactor

Reference No: 3RT1486-6AP36
Catalog No: 3RT1486-6AP36
Rated Current (A): 2100
Rated Voltage (VAC): 690 V
Number of Poles: 3P
0 pcs in stock
$8,458.42

Siemens 3RT1485-6AP36 3RT1 1700A 3P 690V Contactor

Reference No: 3RT1485-6AP36
Catalog No: 3RT1485-6AP36
Rated Current (A): 1700
Rated Voltage (VAC): 690 V
Number of Poles: 3P
0 pcs in stock
$5,950.09

Siemens 3RT1483-6AP36 3RT1 1260A 3P 690V Contactor

Reference No: 3RT1483-6AP36
Catalog No: 3RT1483-6AP36
Rated Current (A): 1260
Rated Voltage (VAC): 690 V
Number of Poles: 3P
0 pcs in stock
$4,538.39

Siemens 3RT1482-6AP36 3RT1 1050A 3P 690V Contactor

Reference No: 3RT1482-6AP36
Catalog No: 3RT1482-6AP36
Rated Current (A): 1050
Rated Voltage (VAC): 690 V
Number of Poles: 3P
0 pcs in stock
$3,237.53

Siemens 3RT1481-6AP36 3RT1 900A 3P 690V Contactor

Reference No: 3RT1481-6AP36
Catalog No: 3RT1481-6AP36
Rated Current (A): 900
Rated Voltage (VAC): 690 V
Number of Poles: 3P
0 pcs in stock
$2,671.75

Siemens 3RT1476-6AP36 3RT1 690A 3P 690V Contactor

Reference No: 3RT1476-6AP36
Catalog No: 3RT1476-6AP36
Rated Current (A): 690
Rated Voltage (VAC): 690 V
Number of Poles: 3P
0 pcs in stock
$1,557.50

Motor control and protection equipment from ABB, Siemens and Schneider Electric covers everything between the supply and the motor shaft. The range spans contactors, overload relays, motor protection circuit breakers, starters, soft starters, variable frequency drives, servo systems and industrial motors, with rated currents from 0.1 A to 2,650 A and power up to 800 kW. Stoklink ships worldwide from Turkey and quotes project volumes on request.

What's in this range

How to choose

  • Motor power and rated current at the supply voltage. Size the starter or drive for the nameplate current, not just the kW value.
  • Starting method: direct on line, soft start or variable speed. This decides whether you need a contactor, a soft starter or a VFD.
  • Duty class, for example AC-3 for squirrel-cage motors under IEC 60947-4-1.
  • Protection split: overload relay plus fuses or MCB, or a single MPCB.
  • Control interface: coil voltage, fieldbus such as PROFINET, and mounting.

FAQ

What is the difference between a soft starter and a VFD?

A soft starter limits inrush current during start and stop at fixed supply frequency. A VFD changes the output frequency, so it also controls speed while running.

Do I need a contactor and an overload relay, or an MPCB?

An MPCB combines short-circuit and overload protection and works with a contactor. The separate route uses a fuse or MCB, a contactor and an overload relay. Choose by space, coordination type and rating.

Can you ship motor control products outside Turkey?

Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, and project quantities are quoted on request.