Filter

Molded Case Circuit Breakers (MCCB)

DEMO
Filter
Showing 1 - 620 of 1818 items

ABB 1SDA060218R1 T6H 800 TMA 800-8000 3p F F 800A 3-Pole Fixed Molded Case Circuit Breaker

Reference No: 1SDA060218R1
Catalog No: T6H 800 TMA 800-8000 3p F F
Rated Current (A): 800
Breaking Capacity (kA): (400 V AC) 70 kA
Number of Poles: 3P
0 pcs in stock
$2,480.14

ABB 1SDA101711R1 XT7H M 1000 Ekip Dip LS/I In1000A 4p F F 4-Pole 1000A 70kA Fixed Moulded Case Circuit Breaker

Reference No: 1SDA101711R1
Catalog No: XT7H M 1000 Ekip Dip LS/I In1000A 4p F F
Rated Current (A): 1000
Breaking Capacity (kA): (400 V AC) 70 kA
Number of Poles: 4P
0 pcs in stock
$2,952.94

ABB 1SDA068765R1 A1C 125 TMF 63-630 1p F F 63A 1P 18kA Moulded Case Circuit Breaker

Reference No: 1SDA068765R1
Catalog No: A1C 125 TMF 63-630 1p F F
Rated Current (A): 63
Breaking Capacity (kA): (240 V AC) 18 kA
Number of Poles: 1P
14 pcs in stock
$44.91

Siemens 3VA1110-4EE46-0AA0 3VA1 4P 100A 36kA 415V TM220 LI Molded Case Circuit Breaker

Reference No: 3VA1110-4EE46-0AA0
Catalog No: 3VA1110-4EE46-0AA0
Rated Current (A): 100
Breaking Capacity (kA): 36 kA @415V AC (Icu, class S)
Rated Voltage (VAC): 690 V AC
Number of Poles: 4P
17 pcs in stock
$257.11

Siemens 3VA1110-4EF36-0AA0 3VA1 3P 100A 36kA 415V TM240 LI Molded Case Circuit Breaker

Reference No: 3VA1110-4EF36-0AA0
Catalog No: 3VA1110-4EF36-0AA0
Rated Current (A): 100
Breaking Capacity (kA): 36 kA @415V AC (Icu, class S)
Rated Voltage (VAC): 690 V AC
Number of Poles: 3P
14 pcs in stock
$181.70

Siemens 3VA1112-6EF36-0AA0 3VA1 3P 125A 70kA 415V TM240 LI Molded Case Circuit Breaker

Reference No: 3VA1112-6EF36-0AA0
Catalog No: 3VA1112-6EF36-0AA0
Rated Current (A): 125
Breaking Capacity (kA): 70 kA @415V AC (Icu, class H)
Rated Voltage (VAC): 690 V AC
Number of Poles: 3P
0 pcs in stock
$374.51

Siemens 3VA1332-6EF32-0AA0 3VA1 3P 320A 70kA 415V TM240 LI Molded Case Circuit Breaker

Reference No: 3VA1332-6EF32-0AA0
Catalog No: 3VA1332-6EF32-0AA0
Rated Current (A): 320
Breaking Capacity (kA): 70 kA @415V AC (Icu, class H)
Rated Voltage (VAC): 690 V AC
Number of Poles: 3P
0 pcs in stock
$1,149.45

Siemens 3VA1580-5MH32-0AA0 3VA1 3P 800A 55kA 415V TM120M I Molded Case Circuit Breaker

Reference No: 3VA1580-5MH32-0AA0
Catalog No: 3VA1580-5MH32-0AA0
Rated Current (A): 800
Breaking Capacity (kA): 55 kA @415V AC (Icu, class M)
Rated Voltage (VAC): 690 V AC
Number of Poles: 3P
0 pcs in stock
$1,869.26

Siemens 3VA2225-5HL42-0AA0 3VA2 4P 250A 55kA 415V ETU320 LI Molded Case Circuit Breaker

Reference No: 3VA2225-5HL42-0AA0
Catalog No: 3VA2225-5HL42-0AA0
Rated Current (A): 250
Breaking Capacity (kA): 55 kA @415V AC (Icu, class M)
Rated Voltage (VAC): 690 V AC
Number of Poles: 4P
3 pcs in stock
$997.03

Siemens 3VA2463-6HL32-0AA0 3VA2 3P 630A 85kA 415V ETU320 LI Molded Case Circuit Breaker

Reference No: 3VA2463-6HL32-0AA0
Catalog No: 3VA2463-6HL32-0AA0
Rated Current (A): 630
Breaking Capacity (kA): 85 kA @415V AC (Icu, class H)
Rated Voltage (VAC): 690 V AC
Number of Poles: 3P
0 pcs in stock
$1,629.10

Siemens 3VA2712-2AC03-0AA0 3VA2 3P 1250A 85kA 415V ETU350 LSI Molded Case Circuit Breaker

Reference No: 3VA2712-2AC03-0AA0
Catalog No: 3VA2712-2AC03-0AA0
Rated Current (A): 1250
Breaking Capacity (kA): 85 kA @415V AC (Icu, class H)
Rated Voltage (VAC): 690 V AC
Number of Poles: 3P
0 pcs in stock
$3,706.02

Siemens 3VM1010-3ED42-0AA0 3VM1 4P 100A 25kA 415V TM210 LI Molded Case Circuit Breaker

Reference No: 3VM1010-3ED42-0AA0
Catalog No: 3VM1010-3ED42-0AA0
Rated Current (A): 100
Breaking Capacity (kA): 25 kA @415V AC (Icu, class N)
Rated Voltage (VAC): 500 V AC
Number of Poles: 4P
23 pcs in stock
$147.04

Siemens 3VM1040-3ED42-0AA0 3VM1 4P 40A 25kA 415V TM210 LI Molded Case Circuit Breaker

Reference No: 3VM1040-3ED42-0AA0
Catalog No: 3VM1040-3ED42-0AA0
Rated Current (A): 40
Breaking Capacity (kA): 25 kA @415V AC (Icu, class N)
Rated Voltage (VAC): 500 V AC
Number of Poles: 4P
10 pcs in stock
$138.87

Siemens 3VM1050-3ED32-0AA0 3VM1 3P 50A 25kA 415V TM210 LI Molded Case Circuit Breaker

Reference No: 3VM1050-3ED32-0AA0
Catalog No: 3VM1050-3ED32-0AA0
Rated Current (A): 50
Breaking Capacity (kA): 25 kA @415V AC (Icu, class N)
Rated Voltage (VAC): 500 V AC
Number of Poles: 3P
66 pcs in stock
$103.25

Siemens 3VM1125-3EE32-0AA0 3VM1 3P 25A 25kA 415V TM220 LI Molded Case Circuit Breaker

Reference No: 3VM1125-3EE32-0AA0
Catalog No: 3VM1125-3EE32-0AA0
Rated Current (A): 25
Breaking Capacity (kA): 25 kA @415V AC (Icu, class N)
Rated Voltage (VAC): 500 V AC
Number of Poles: 3P
0 pcs in stock
$117.27

Siemens 3VA1112-5EF46-0AA0 3VA1 4P 125A 55kA 415V TM240 LI Molded Case Circuit Breaker

Reference No: 3VA1112-5EF46-0AA0
Catalog No: 3VA1112-5EF46-0AA0
Rated Current (A): 125
Breaking Capacity (kA): 55 kA @415V AC (Icu, class M)
Rated Voltage (VAC): 690 V AC
Number of Poles: 4P
0 pcs in stock
$541.75

Siemens 3VA1112-5MH36-0AA0 3VA1 3P 125A 55kA 415V TM120M I Molded Case Circuit Breaker

Reference No: 3VA1112-5MH36-0AA0
Catalog No: 3VA1112-5MH36-0AA0
Rated Current (A): 125
Breaking Capacity (kA): 55 kA @415V AC (Icu, class M)
Rated Voltage (VAC): 690 V AC
Number of Poles: 3P
9 pcs in stock
$307.80

Siemens 3VA1116-4EF46-0AA0 3VA1 4P 160A 36kA 415V TM240 LI Molded Case Circuit Breaker

Reference No: 3VA1116-4EF46-0AA0
Catalog No: 3VA1116-4EF46-0AA0
Rated Current (A): 160
Breaking Capacity (kA): 36 kA @415V AC (Icu, class S)
Rated Voltage (VAC): 690 V AC
Number of Poles: 4P
37 pcs in stock
$482.25

Siemens 3VA1120-5EE46-0AA0 3VA1 4P 20A 55kA 415V TM220 LI Molded Case Circuit Breaker

Reference No: 3VA1120-5EE46-0AA0
Catalog No: 3VA1120-5EE46-0AA0
Rated Current (A): 20
Breaking Capacity (kA): 55 kA @415V AC (Icu, class M)
Rated Voltage (VAC): 690 V AC
Number of Poles: 4P
0 pcs in stock
$293.00

Siemens 3VA1132-4EE36-0AA0 3VA1 3P 32A 36kA 415V TM220 LI Molded Case Circuit Breaker

Reference No: 3VA1132-4EE36-0AA0
Catalog No: 3VA1132-4EE36-0AA0
Rated Current (A): 32
Breaking Capacity (kA): 36 kA @415V AC (Icu, class S)
Rated Voltage (VAC): 690 V AC
Number of Poles: 3P
28 pcs in stock
$178.01

Molded case circuit breakers (MCCB) from ABB, Schneider Electric and Siemens protect feeders, motors and distribution boards from about 10 A up to 1600 A. The range covers 3-pole and 4-pole breakers with fixed and adjustable trip units, with more than 1,800 products including accessories. Stoklink ships worldwide from Turkey and quotes project volumes on request.

What's in this range

How to choose

  • Frame size and rated current, with the trip unit set to the load current.
  • Rated breaking capacity (Icu and Ics) at the system voltage, above the prospective short-circuit current.
  • Trip unit: thermal-magnetic for simple feeders, electronic (LSI or LSIG) where selectivity is needed.
  • Poles: 3P or 4P according to the neutral arrangement. Standard: IEC 60947-2.

FAQ

What is the difference between an MCCB and an ACB?

An MCCB is a compact molded-case breaker, typically used from tens of amperes to 1600 A. An ACB is a larger, often draw-out breaker for main incomers from 630 A upward.

What do Icu and Ics mean on an MCCB?

Icu is the ultimate breaking capacity. Ics is the service breaking capacity, the share of Icu after which the breaker stays fit for service.

Do you export MCCBs and their accessories?

Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so request a quote with your part numbers and quantities.