Filter

DIN Rail Power Supplies (24V DC)

Filter
Showing 1 - 206 of 206 items

ABB 1SVR427030R0000 CP-E 24/0.75 24VDC 0.75A 18W 100-240VAC Input DC Power Supply

Reference No: 1SVR427030R0000
Catalog No: CP-E 24/0.75
Rated Current (A): 0.75
Rated Voltage (VAC): 100/240 V AC
0 pcs in stock
$62.38

ABB 1SVR427034R0000 CP-E 24/5.0 24VDC 5A 120W DIN Rail DC Power Supply

Reference No: 1SVR427034R0000
Catalog No: CP-E 24/5.0
Rated Current (A): 5
Rated Voltage (VAC): 115/230 V AC
8 pcs in stock
$109.66

ABB 1SVR427036R0000 CP-E 24/20.0 24VDC 20A 480W 115/230VAC Input DC Power Supply

Reference No: 1SVR427036R0000
Catalog No: CP-E 24/20.0
Rated Current (A): 20
Rated Voltage (VAC): 115/230 V AC
1 pcs in stock
$234.15

ABB 1SVR427035R0000 CP-E 24/10.0 24VDC 10A 240W 115/230VAC Input DC Power Supply

Reference No: 1SVR427035R0000
Catalog No: CP-E 24/10.0
Rated Current (A): 10
Rated Voltage (VAC): 115/230 V AC
1 pcs in stock
$149.17

ABB 1SVR427044R0200 CP-D 24/2.5 24VDC 2.5A 60W 100-240VAC Input Switch Mode Power Supply

Reference No: 1SVR427044R0200
Catalog No: CP-D 24/2.5
Rated Current (A): 2.5
Rated Voltage (VAC): 100/240 V AC
0 pcs in stock
$71.52

ABB 1SDA074172R1 EKIP SUPPLY 110-240VAC/DC E1.2..E6.2-XT Power Supply Module

Reference No: 1SDA074172R1
Catalog No: EKIP SUPPLY 110-240VAC/DC E1.2..E6.2-XT
22 pcs in stock
$98.14

DIN rail power supplies (24 V DC) from Siemens, Schneider Electric and ABB, with over 200 products for control panels, PLCs and field devices. Series include Siemens SITOP PSU100C, PSU4200, PSU6200 and PSU8200 and Schneider Electric Modicon ABL2. Stoklink ships worldwide from Turkey and quotes project volumes on request.

What's in this range

  • Siemens SITOP PSU100C and PSU4200 for single-phase panel supply.
  • Siemens SITOP PSU6200 and PSU8200, including 3-phase input versions.
  • Schneider Electric Modicon regulated supplies, for example 24 V DC at 2.5 A and 10 A.
  • Siemens 4RB2, 4RB8 and 4EU3 ranges.

How to choose

  • Output current: total all 24 V loads and keep a reserve of 20 to 30 percent.
  • Input: single-phase 100-240 V AC or 3-phase 400-500 V AC.
  • Parallel use: add a redundancy module when two supplies share a load.

FAQ

Which output current suits a PLC panel?

Add the current of the PLC, I/O, relays and sensors, then round up to the next rating, such as 5 A or 10 A.

Can I run two supplies in parallel?

Only if the datasheet allows it, normally through a redundancy module.

Do you quote larger quantities?

Yes. Request a quote. Stoklink ships worldwide from Turkey under EXW terms.