- Home
- All Collections
- Contactors
Contactors
Schneider Electric LC1D40AKUE TeSys Deca Advanced Contactor 3P 3NO AC-3 40 A 100-250 V AC/DC Coil Contactor
Schneider Electric LC1D95ED TeSys Deca Contactor 3P 3NO AC-3 95 A 48 V DC Coil Contactor
Schneider Electric LC1D50ABNE TeSys Deca Advanced Contactor 3P 3NO AC-3 50 A 24-60 V AC/DC Coil Contactor
Schneider Electric LC1D95Q7 TeSys Deca Contactor 3P 3NO AC-3 95 A 380 V AC Coil Contactor
Schneider Electric LC1D50AEHE TeSys Deca Advanced Contactor 3P 3NO AC-3 50 A 48-130 V AC/DC Coil Contactor
Schneider Electric LC1D95V7 TeSys Deca Contactor 3P 3NO AC-3 95 A 400 V AC Coil Contactor
Schneider Electric LC1D50AKUE TeSys Deca Advanced Contactor 3P 3NO AC-3 50 A 100-250 V AC/DC Coil Contactor
Schneider Electric LC1DT20FD TeSys Deca Contactor 4P 4NO AC-1 20 A 110 V DC Coil Contactor
Schneider Electric LC1D65ABNE TeSys Deca Advanced Contactor 3P 3NO AC-3 65 A 24-60 V AC/DC Coil Contactor
Schneider Electric LC1DT25B7 TeSys Deca Contactor 4P 4NO AC-1 25 A 24 V AC Coil Contactor
Schneider Electric LC1D65AKUE TeSys Deca Advanced Contactor 3P 3NO AC-3 65 A 100-250 V AC/DC Coil Contactor
Schneider Electric LC1DT25ED TeSys Deca Contactor 4P 4NO AC-1 25 A 48 V DC Coil Contactor
Schneider Electric LC1D80AKUE TeSys Deca Advanced Contactor 3P 3NO AC-3 66 A 100-250 V AC/DC Coil Contactor
Schneider Electric LC1DT25FD TeSys Deca Contactor 4P 4NO AC-1 25 A 110 V DC Coil Contactor
Schneider Electric LC1DT200A6EHE TeSys Deca Advanced Contactor 4P 4NO AC-1 200 A 48-130 V AC/DC Coil Contactor
Schneider Electric LC1DT32F7 TeSys Deca Contactor 4P 4NO AC-1 32 A 110 V AC Coil Contactor
Schneider Electric LC1DT200A6KUE TeSys Deca Advanced 4P 4NO AC-1 200 A 100-250 V AC/DC Coil Contactor
Schneider Electric LC1DT40B7 TeSys Deca Contactor 4P 4NO AC-1 40 A 24 V AC Coil Contactor
Schneider Electric LC1DT200AKUE TeSys Deca Advanced Contactor 4P 4NO AC-1 200 A 100-250 V AC/DC Coil Contactor
Schneider Electric LC1DT40BD TeSys Deca Contactor 4P 4NO AC-1 40 A 24 V DC Coil Contactor
Contactors from ABB, Schneider Electric and Siemens switch motor and load circuits on and off by remote control. This range covers over 900 products, from 2 A accessories to power contactors rated up to 2650 A, with motor ratings from 2.2 kW to 450 kW in 2, 3, 4 and 8 pole versions. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- Power Contactors (AC-3) – the main motor-switching contactors, including ABB AF, TeSys Deca, TeSys Giga, TeSys K, Easy TeSys and SIRIUS 3RT2 and 3RT1.
- Contactor Relays & Auxiliary Contactors – control-circuit relays with several auxiliary contacts.
- Installation Contactors – DIN-rail contactors for distribution boards, such as ABB ESB.
- Contactor Accessories (Coils, Aux Blocks) – replacement coils, auxiliary contact blocks and mounting parts.
How to choose
- Utilization category: AC-3 for squirrel-cage motor starting, AC-1 for resistive loads. The same frame carries a different current in each category.
- Rated current and motor power at your operating voltage, with margin for the duty cycle.
- Number of poles: 3P for three-phase motors, 4P for switching the neutral or four-wire loads.
- Coil voltage and type (AC, DC or AC/DC). It must match the control supply.
- Auxiliary contacts: count the NO and NC contacts the control circuit needs, and check if the contactor accepts add-on blocks.
FAQ
What is the difference between a contactor and a contactor relay?
A power contactor switches the main circuit of a motor or load. A contactor relay switches control circuits at low current, typically 10 A, and has more auxiliary contacts.
Which standard applies to contactors?
Low-voltage contactors are covered by IEC 60947-4-1. The standard defines utilization categories such as AC-1 and AC-3.
Do you ship contactors outside Turkey?
Yes. Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so send the part numbers for a quote. Project quantities are quoted on request.