- Home
- All Collections
- Contactors
Contactors
Siemens 3RT2037-1NB30 3RT2 65A 3P 400V Contactor
Siemens 3RT2046-1AP00 3RT2 95A 3P 400V Contactor
Siemens 3RT2047-1AP00 3RT2 110A 3P 400V Contactor
Siemens 3RT2916-1JL00 3RT2 240V Contactor
Schneider Electric LC1D18BL LC1D 3-Pole 18A 480V AC 10HP TeSys Deca Contactor
Schneider Electric LC1E3810M5 EasyPact TVS 3P 38A 440V AC Contactor
Schneider Electric LA1KN20 TeSys K 2NO Front Mount Auxiliary Contact Block
Siemens 3RT1363-6AP36 3RT1 275A 4P 400V Contactor
Siemens 3RT1965-5AP31 3RT1 240V Contactor
Siemens 3RT2016-2BB41 3RT2 9A 3P 400V Contactor
Siemens 3RT2017-1BB42 3RT2 12A 3P 400V Contactor
Siemens 3RT2023-1AP00 3RT2 9A 3P 400V Contactor
Siemens 3RT2025-2BB40 3RT2 17A 3P 400V Contactor
Siemens 3RT2027-1AP00 3RT2 32A 3P 400V Contactor
Siemens 3RT2027-2BB40 3RT2 32A 3P 400V Contactor
Siemens 3RT2028-1AP00 3RT2 38A 3P 400V Contactor
Siemens 3RT2038-1AP00 3RT2 80A 3P 400V Contactor
Siemens 3RT2038-1NB30 3RT2 80A 3P 400V Contactor
ABB 1SBH136001R2144 NFZ44E-21 8-Pole 24-60V AC/DC Contactor Relay
Schneider Electric LP1K1210BD TeSys K 3P 12A 5.5kW 24V DC Coil AC-3 Power Contactor
Contactors from ABB, Schneider Electric and Siemens switch motor and load circuits on and off by remote control. This range covers over 900 products, from 2 A accessories to power contactors rated up to 2650 A, with motor ratings from 2.2 kW to 450 kW in 2, 3, 4 and 8 pole versions. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- Power Contactors (AC-3) – the main motor-switching contactors, including ABB AF, TeSys Deca, TeSys Giga, TeSys K, Easy TeSys and SIRIUS 3RT2 and 3RT1.
- Contactor Relays & Auxiliary Contactors – control-circuit relays with several auxiliary contacts.
- Installation Contactors – DIN-rail contactors for distribution boards, such as ABB ESB.
- Contactor Accessories (Coils, Aux Blocks) – replacement coils, auxiliary contact blocks and mounting parts.
How to choose
- Utilization category: AC-3 for squirrel-cage motor starting, AC-1 for resistive loads. The same frame carries a different current in each category.
- Rated current and motor power at your operating voltage, with margin for the duty cycle.
- Number of poles: 3P for three-phase motors, 4P for switching the neutral or four-wire loads.
- Coil voltage and type (AC, DC or AC/DC). It must match the control supply.
- Auxiliary contacts: count the NO and NC contacts the control circuit needs, and check if the contactor accepts add-on blocks.
FAQ
What is the difference between a contactor and a contactor relay?
A power contactor switches the main circuit of a motor or load. A contactor relay switches control circuits at low current, typically 10 A, and has more auxiliary contacts.
Which standard applies to contactors?
Low-voltage contactors are covered by IEC 60947-4-1. The standard defines utilization categories such as AC-1 and AC-3.
Do you ship contactors outside Turkey?
Yes. Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so send the part numbers for a quote. Project quantities are quoted on request.