- Home
- All Collections
- Contactors
Contactors
Schneider Electric LC1K1201B7 TeSys K 3-Pole 12A 440V AC Contactor
Schneider Electric LC1K0601M7 TeSys K 3-Pole 6A 440V AC Contactor
Schneider Electric LC1D09E7 TeSys Deca 3-Pole 9A 480V AC Coil 5HP Power Contactor
Schneider Electric LC1E2510BD Easy TeSys Control LC1E 3P 25A 24VDC Contactor
Schneider Electric LC1E0910BD Easy TeSys Control LC1E 3P 9A 24VDC Contactor
Siemens 3RT1065-6AP36 3RT1 265A 3P 400V Contactor
Siemens 3RT2016-1AP02 3RT2 9A 3P 400V Contactor
Siemens 3RT2016-1BB41 3RT2 9A 3P 400V Contactor
Siemens 3RT2016-2AP02 3RT2 9A 3P 400V Contactor
Siemens 3RT2018-1BB42 3RT2 16A 3P 400V Contactor
Siemens 3RT2024-2BB40 3RT2 12A 3P 400V Contactor
Siemens 3RT2027-1BB40 3RT2 32A 3P 400V Contactor
Siemens 3RT2336-1AP00 3RT2 60A 4P 400V Contactor
Siemens 3RT2926-1CD00 3RT2 240V Contactor
Siemens 3RT2936-1CB00 3RT2 48V Contactor
Siemens 3RT2947-6A 3RT2 Contactor
Schneider Electric LC1K1610B7 TeSys K 3-Pole 16A 440V AC Contactor
Schneider Electric LC1D12E7 TeSys Deca 3-Pole 12A 480V AC 7.5HP Motor Contactor
ABB 1SBN011010T1001 CA3-01 1NO Front-Mount Auxiliary Contact Block 10A 690V
Schneider Electric LC1D80B7 TeSys Deca 3-Pole 80A 60HP 480V AC Coil 24V AC Contactor
Contactors from ABB, Schneider Electric and Siemens switch motor and load circuits on and off by remote control. This range covers over 900 products, from 2 A accessories to power contactors rated up to 2650 A, with motor ratings from 2.2 kW to 450 kW in 2, 3, 4 and 8 pole versions. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- Power Contactors (AC-3) – the main motor-switching contactors, including ABB AF, TeSys Deca, TeSys Giga, TeSys K, Easy TeSys and SIRIUS 3RT2 and 3RT1.
- Contactor Relays & Auxiliary Contactors – control-circuit relays with several auxiliary contacts.
- Installation Contactors – DIN-rail contactors for distribution boards, such as ABB ESB.
- Contactor Accessories (Coils, Aux Blocks) – replacement coils, auxiliary contact blocks and mounting parts.
How to choose
- Utilization category: AC-3 for squirrel-cage motor starting, AC-1 for resistive loads. The same frame carries a different current in each category.
- Rated current and motor power at your operating voltage, with margin for the duty cycle.
- Number of poles: 3P for three-phase motors, 4P for switching the neutral or four-wire loads.
- Coil voltage and type (AC, DC or AC/DC). It must match the control supply.
- Auxiliary contacts: count the NO and NC contacts the control circuit needs, and check if the contactor accepts add-on blocks.
FAQ
What is the difference between a contactor and a contactor relay?
A power contactor switches the main circuit of a motor or load. A contactor relay switches control circuits at low current, typically 10 A, and has more auxiliary contacts.
Which standard applies to contactors?
Low-voltage contactors are covered by IEC 60947-4-1. The standard defines utilization categories such as AC-1 and AC-3.
Do you ship contactors outside Turkey?
Yes. Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so send the part numbers for a quote. Project quantities are quoted on request.