Schneider Electric LADN20 TeSys Deca 2NO Top Mount Auxiliary Contact Block
Siemens 5TT5840-0 5TT5 40A 230V Contactor
ABB 1SBH137001R1353 NF53E-13 8-Pole 100-250V AC/DC 690V IEC Contactor Relay
Schneider Electric A9C22712 iCT 16A 230-240V AC Contactor
Schneider Electric LC1D150F7 TeSys Deca 3-Pole 150A 480V AC 100HP 100kA SCCR Contactor
Schneider Electric LC1D25M7 TeSys Deca 3-Pole 25A 15HP 480V AC Contactor
Siemens 3RT1054-1AP36 3RT1 115A 3P 400V Contactor
Siemens 3RT2023-2BB40 3RT2 9A 3P 400V Contactor
Siemens 3RT2046-1NB30 3RT2 95A 3P 400V Contactor
ABB 1SBN050010R1002 RV5/250 Surge Suppressor 110-250V AC/DC Clip-On Accessories/Spare Parts for Low-Voltage Switch Technology
Schneider Electric LC1E40M5 Easy TeSys 3-Pole 40A 440V AC Contactor
Schneider Electric LC1D12F7 TeSys Deca 3-Pole 12A 480V AC Coil 7.5HP Power Contactor
Schneider Electric LC1D09M7 TeSys Deca 9A 3-Pole 480V AC Coil 5HP Power Contactor
Schneider Electric LC1D09B7 TeSys Deca 3-Pole 9A 480VAC Coil 24V AC-3 Motor Contactor
ABB 1SBL137201R1300 AF09-40-00-13 4-Pole 25A 690V 4kW 100-250V Coil AC/DC Power Contactor
ABB 1SFL527002R1311 AF205-30-11-13 3-Pole 350A 1000V AC-1 110kW Power Contactor AC Switching
Schneider Electric LC1K0901M7 TeSys K 3-Pole 9A 440V AC Contactor
Siemens 3RT1066-6AP36 3RT1 300A 3P 400V Contactor
Siemens 3RT2325-1AP00 3RT2 35A 4P 400V Contactor
Siemens 5TT5830-0 5TT5 25A 230V Contactor
Contactors from ABB, Schneider Electric and Siemens switch motor and load circuits on and off by remote control. This range covers over 900 products, from 2 A accessories to power contactors rated up to 2650 A, with motor ratings from 2.2 kW to 450 kW in 2, 3, 4 and 8 pole versions. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- Power Contactors (AC-3) – the main motor-switching contactors, including ABB AF, TeSys Deca, TeSys Giga, TeSys K, Easy TeSys and SIRIUS 3RT2 and 3RT1.
- Contactor Relays & Auxiliary Contactors – control-circuit relays with several auxiliary contacts.
- Installation Contactors – DIN-rail contactors for distribution boards, such as ABB ESB.
- Contactor Accessories (Coils, Aux Blocks) – replacement coils, auxiliary contact blocks and mounting parts.
How to choose
- Utilization category: AC-3 for squirrel-cage motor starting, AC-1 for resistive loads. The same frame carries a different current in each category.
- Rated current and motor power at your operating voltage, with margin for the duty cycle.
- Number of poles: 3P for three-phase motors, 4P for switching the neutral or four-wire loads.
- Coil voltage and type (AC, DC or AC/DC). It must match the control supply.
- Auxiliary contacts: count the NO and NC contacts the control circuit needs, and check if the contactor accepts add-on blocks.
FAQ
What is the difference between a contactor and a contactor relay?
A power contactor switches the main circuit of a motor or load. A contactor relay switches control circuits at low current, typically 10 A, and has more auxiliary contacts.
Which standard applies to contactors?
Low-voltage contactors are covered by IEC 60947-4-1. The standard defines utilization categories such as AC-1 and AC-3.
Do you ship contactors outside Turkey?
Yes. Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so send the part numbers for a quote. Project quantities are quoted on request.