- Home
- All Collections
- Circuit Breakers & Protection
Circuit Breakers & Protection
Circuit Breakers & Protection Categories
Circuit Breakers & Protection
ABB 1SDA071161R1 E4.2H 3200 Ekip Dip LI 3p F HR 3200A 3P 100kA Air Circuit Breaker
ABB 1SDA071081R1 E2.2H 2500 Ekip Dip LI 3p F HR 2500A 3P 100kA Fixed Air Power Circuit Breaker
ABB 1SDA071202R1 E4.2S 4000 Ekip Dip LSI 3p F HR 4000A 85kA 3-Pole Fixed Power Circuit Breaker
ABB 1SDA071152R1 E4.2S 3200 Ekip Dip LSI 3p F HR 3200A 85kA 3-Pole Fixed Air Circuit Breaker
ABB 1SDA071042R1 E2.2S 2000 Ekip Dip LSI 3p F HR 2000A 85kA 3-Pole Fixed Power Circuit Breaker
ABB 1SDA071201R1 E4.2S 4000 Ekip Dip LI 3p F HR 4000A 3P 85kA Fixed Power Circuit Breaker
ABB 1SDA071151R1 E4.2S 3200 Ekip Dip LI 3p F HR 3200A 85kA 3-Pole Fixed Air Circuit Breaker
ABB 1SDA071071R1 E2.2S 2500 Ekip Dip LI 3p F HR 2500A 85kA 3-Pole Fixed Power Circuit Breaker
ABB 1SDA071041R1 E2.2S 2000 Ekip Dip LI 3p F HR 2000A 85kA Air Circuit Breaker
ABB 1SDA071192R1 E4.2N 4000 Ekip Dip LSI 3p F HR 4000A 3P 66kA Fixed Power Circuit Breaker
ABB 1SDA071142R1 E4.2N 3200 Ekip Dip LSI 3p F HR 3200A 3P 66kA Fixed Power Circuit Breaker
ABB 1SDA071062R1 E2.2N 2500 Ekip Dip LSI 3p F HR 2500A 3P 66kA Fixed Power Circuit Breaker
ABB 1SDA071032R1 E2.2N 2000 Ekip Dip LSI 3p F HR 2000A 3P 66kA Fixed Air Circuit Breaker
ABB 1SDA070992R1 E2.2N 1600 Ekip Dip LSI 3p F HR 1600A 66kA 3-Pole Fixed Power Circuit Breaker
ABB 1SDA070952R1 E2.2N 1250 Ekip Dip LSI 3p F HR 1250A 3P 66kA Fixed Power Circuit Breaker
ABB 1SDA070802R1 E1.2N 1000 Ekip Dip LSI 3p F F 1000A 3P 66kA Air Circuit Breaker
ABB 1SDA070762R1 E1.2N 800 Ekip Dip LSI 3p F F 800A 66kA 3-Pole Fixed Air Circuit Breaker
ABB 1SDA071191R1 E4.2N 4000 Ekip Dip LI 3p F HR 4000A 3P 66kA Air Circuit Breaker
ABB 1SDA071141R1 E4.2N 3200 Ekip Dip LI 3p F HR 3200A 3P 66kA Air Circuit Breaker
ABB 1SDA071061R1 E2.2N 2500 Ekip Dip LI 3p F HR 2500A 3P 66kA Fixed Power Circuit Breaker
Circuit breakers and protection devices from ABB, Siemens, Schneider Electric and Mersen cover the full low-voltage protection chain, from miniature circuit breakers to air circuit breakers up to 6300 A. The range includes MCB, MCCB, ACB, residual current devices, arc fault detection devices and surge protective devices in 1 to 4 poles, with more than 4,500 listed products. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- Miniature Circuit Breakers (MCB) – DIN-rail overcurrent protection for final circuits and distribution boards.
- Molded Case Circuit Breakers (MCCB) – feeder and motor-circuit protection with adjustable trip units.
- Air Circuit Breakers (ACB) – main incomer and bus-tie breakers from 630 A to 6300 A.
- Residual Current Devices (RCD) – earth-leakage protection against shock and fire.
- Arc Fault Detection Devices (AFDD) – detection of series and parallel arcs in final circuits.
- Surge Protective Devices (SPD) – protection of installations against transient overvoltage.
How to choose
- Rated current and pole count, matched to the load and the neutral arrangement.
- Breaking capacity at the installation voltage, at or above the prospective short-circuit current.
- Standard: IEC 60898-1 for household and similar MCBs, IEC 60947-2 for industrial breakers, IEC 61008 and 61009 for RCDs.
- Trip characteristic or trip unit type, and coordination with upstream and downstream devices.
FAQ
What is the difference between an MCB and an MCCB?
An MCB is a DIN-rail breaker for final circuits, usually with fixed thermal-magnetic tripping. An MCCB covers higher currents and short-circuit levels and often has adjustable or electronic trip units.
Do I need an RCD in addition to a circuit breaker?
Yes, where earth-leakage protection is required. A standard breaker protects against overload and short circuit, while an RCD detects leakage current to earth.
Can you ship circuit breakers outside Turkey?
Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so request a quote with your part numbers and quantities.