- Home
- All Collections
- Circuit Breakers & Protection
Circuit Breakers & Protection
Circuit Breakers & Protection Categories
Circuit Breakers & Protection
ABB 2CDS653061R0065 BMS613B06 3P 6A 10kA 480Y/277V AC 500V DC Miniature Circuit Breaker
ABB 2CDS653061R0165 BMS613B16 3P 16A 6kA 400V DIN Rail Miniature Circuit Breaker
ABB 2CDS653061R0205 BMS613B20 3P 20A 6kA 400V DIN Rail Miniature Circuit Breaker
ABB 2CDS653061R0255 BMS613B25 3P 25A 6kA 400V AC Miniature Circuit Breaker
ABB 2CDS653061R0405 BMS613B40 3P 40A 6kA 400V AC DIN Rail Miniature Circuit Breaker
ABB 2CDS653061R0325 BMS613B32 3P 32A 10kA 500V DC Miniature Circuit Breaker
ABB 2CDS653061R0105 BMS613B10 3P 10A 6kA 400V B-Curve Miniature Circuit Breaker
ABB 2CDS651061R0405 BMS611B40 1P 40A 6kA B-Curve DIN Rail Miniature Circuit Breaker
ABB 2CDS651061R0205 BMS611B20 1P 20A 6kA B-Curve 230V AC Miniature Circuit Breaker
ABB 2CDS651061R0325 BMS611B32 1P 32A 6kA B-Curve Miniature Circuit Breaker
ABB 2CDS651061R0065 BMS611B06 1P 6A 6kA B-Curve Miniature Circuit Breaker
ABB 2CDS651061R0255 BMS611B25 1P 25A 6kA B-Curve Miniature Circuit Breaker
ABB 2CDS651061R0105 BMS611B10 1P 10A 6kA B-Curve Miniature Circuit Breaker
ABB 2CDS651061R0165 BMS611B16 1P 16A 6kA B-Curve Miniature Circuit Breaker
ABB 2CSF204001R3400 F204 AC-40/0.3 4P 40A 0.3A DIN-Rail Residual Current Circuit Breaker (RCCB)
ABB 2CSF204001R1400 F204 AC-40/0.03 4P 40A 30mA DIN-Rail Residual Current Circuit Breaker
ABB 2CSF202001R1400 F202 AC-40/0.03 2P 40A 30mA Type AC Residual Current Circuit Breaker
ABB 2CSF202001R1250 F202 AC-25/0.03 2P 25A 30mA DIN-Rail Residual Current Circuit Breaker
ABB 2CSF204001R1250 F204 AC-25/0.03 4P 25A RCCB DIN-Rail Residual Current Circuit Breaker
ABB 2CSF204001R3250 F204 AC-25/0.3 4P 25A Residual Current Circuit Breaker (RCCB) DIN-Rail
Circuit breakers and protection devices from ABB, Siemens, Schneider Electric and Mersen cover the full low-voltage protection chain, from miniature circuit breakers to air circuit breakers up to 6300 A. The range includes MCB, MCCB, ACB, residual current devices, arc fault detection devices and surge protective devices in 1 to 4 poles, with more than 4,500 listed products. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- Miniature Circuit Breakers (MCB) – DIN-rail overcurrent protection for final circuits and distribution boards.
- Molded Case Circuit Breakers (MCCB) – feeder and motor-circuit protection with adjustable trip units.
- Air Circuit Breakers (ACB) – main incomer and bus-tie breakers from 630 A to 6300 A.
- Residual Current Devices (RCD) – earth-leakage protection against shock and fire.
- Arc Fault Detection Devices (AFDD) – detection of series and parallel arcs in final circuits.
- Surge Protective Devices (SPD) – protection of installations against transient overvoltage.
How to choose
- Rated current and pole count, matched to the load and the neutral arrangement.
- Breaking capacity at the installation voltage, at or above the prospective short-circuit current.
- Standard: IEC 60898-1 for household and similar MCBs, IEC 60947-2 for industrial breakers, IEC 61008 and 61009 for RCDs.
- Trip characteristic or trip unit type, and coordination with upstream and downstream devices.
FAQ
What is the difference between an MCB and an MCCB?
An MCB is a DIN-rail breaker for final circuits, usually with fixed thermal-magnetic tripping. An MCCB covers higher currents and short-circuit levels and often has adjustable or electronic trip units.
Do I need an RCD in addition to a circuit breaker?
Yes, where earth-leakage protection is required. A standard breaker protects against overload and short circuit, while an RCD detects leakage current to earth.
Can you ship circuit breakers outside Turkey?
Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so request a quote with your part numbers and quantities.