Filter

ABB Tmax XT MCCBs

Filter
Showing 1 - 153 of 153 items

ABB 1SDA067450R1 XT1H 160 TMD 63-630 3p F F 63A 3-Pole Fixed Molded Case Circuit Breaker

Reference No: 1SDA067450R1
Catalog No: XT1H 160 TMD 63-630 3p F F
Rated Current (A): 63
Breaking Capacity (kA): (400 V AC) 70 kA
Number of Poles: 3P
2 pcs in stock
$117.45

ABB 1SDA067449R1 XT1H 160 TMD 50-500 3p F F 50A 3-Pole Fixed Molded Case Circuit Breaker

Reference No: 1SDA067449R1
Catalog No: XT1H 160 TMD 50-500 3p F F
Rated Current (A): 50
Breaking Capacity (kA): (400 V AC) 70 kA
Number of Poles: 3P
1 pcs in stock
$117.45

ABB 1SDA080838R1 XT1H 160 TMD 32-450 3p F F 32A 3P Fixed Power Circuit Breaker

Reference No: 1SDA080838R1
Catalog No: XT1H 160 TMD 32-450 3p F F
Rated Current (A): 32
Breaking Capacity (kA): (400 V AC) 70 kA
Number of Poles: 3P
0 pcs in stock
$117.45

ABB 1SDA067436R1 XT1S 160 TMD 160-1600 3p F F 160A 3-Pole Fixed Moulded Case Circuit Breaker

Reference No: 1SDA067436R1
Catalog No: XT1S 160 TMD 160-1600 3p F F
Rated Current (A): 160
Breaking Capacity (kA): (400 V AC) 50 kA
Number of Poles: 3P
78 pcs in stock
$167.67

ABB 1SDA067435R1 XT1S 160 TMD 125-1250 3p F F 3-Pole 125A Fixed Moulded Case Circuit Breaker

Reference No: 1SDA067435R1
Catalog No: XT1S 160 TMD 125-1250 3p F F
Rated Current (A): 125
Breaking Capacity (kA): (400 V AC) 50 kA
Number of Poles: 3P
67 pcs in stock
$161.51

ABB 1SDA067434R1 XT1S 160 TMD 100-1000 3p F F 3-Pole 100A Fixed Moulded Case Circuit Breaker

Reference No: 1SDA067434R1
Catalog No: XT1S 160 TMD 100-1000 3p F F
Rated Current (A): 100
Breaking Capacity (kA): (400 V AC) 50 kA
Number of Poles: 3P
48 pcs in stock
$131.49

ABB 1SDA067431R1 XT1S 160 TMD 50-500 3p F F 50A 3-Pole Fixed Molded Case Circuit Breaker

Reference No: 1SDA067431R1
Catalog No: XT1S 160 TMD 50-500 3p F F
Rated Current (A): 50
Breaking Capacity (kA): (400 V AC) 50 kA
Number of Poles: 3P
38 pcs in stock
$131.49

ABB 1SDA067418R1 XT1N 160 TMD 160-1600 3p F F 160A 3-Pole Fixed Moulded Case Circuit Breaker

Reference No: 1SDA067418R1
Catalog No: XT1N 160 TMD 160-1600 3p F F
Rated Current (A): 160
Breaking Capacity (kA): (400 V AC) 36 kA
Number of Poles: 3P
1115 pcs in stock
$146.30

ABB 1SDA067417R1 XT1N 160 TMD 125-1250 3p F F 125A 3-Pole Fixed Moulded Case Circuit Breaker for Transformer Generator Installation Protection

Reference No: 1SDA067417R1
Catalog No: XT1N 160 TMD 125-1250 3p F F
Rated Current (A): 125
Breaking Capacity (kA): (400 V AC) 36 kA
Number of Poles: 3P
467 pcs in stock
$142.11

ABB 1SDA067415R1 XT1N 160 TMD 80-800 3p F F 80A 3-Pole Fixed Moulded Case Circuit Breaker

Reference No: 1SDA067415R1
Catalog No: XT1N 160 TMD 80-800 3p F F
Rated Current (A): 80
Breaking Capacity (kA): (400 V AC) 36 kA
Number of Poles: 3P
418 pcs in stock
$124.60

ABB 1SDA067414R1 XT1N 160 TMD 63-630 3p F F 3-Pole 63A Fixed Moulded Case Circuit Breaker

Reference No: 1SDA067414R1
Catalog No: XT1N 160 TMD 63-630 3p F F
Rated Current (A): 63
Breaking Capacity (kA): (400 V AC) 36 kA
Number of Poles: 3P
508 pcs in stock
$124.60

ABB 1SDA067412R1 XT1N 160 TMD 40-450 3p F F 40A 3-Pole Fixed Moulded Case Circuit Breaker

Reference No: 1SDA067412R1
Catalog No: XT1N 160 TMD 40-450 3p F F
Rated Current (A): 40
Breaking Capacity (kA): (400 V AC) 36 kA
Number of Poles: 3P
473 pcs in stock
$124.60

ABB 1SDA067411R1 XT1N 160 TMD 32-450 3p F F 32A 3-Pole Fixed Moulded Case Circuit Breaker Tmax XT1

Reference No: 1SDA067411R1
Catalog No: XT1N 160 TMD 32-450 3p F F
Rated Current (A): 32
Breaking Capacity (kA): (400 V AC) 36 kA
Number of Poles: 3P
300 pcs in stock
$124.60

ABB Tmax XT MCCBs are molded case circuit breakers for feeder and motor protection from 10 A to 1600 A. The range covers 3-pole and 4-pole fixed breakers across XT1 to XT7 frames, with more than 200 products. Stoklink ships worldwide from Turkey and quotes volumes on request.

What's in this range

  • XT1 to XT4 frames with TMD and TMA thermal-magnetic trip units.
  • XT5 and XT6 frames for 400 A to 800 A feeders.
  • Ekip electronic trip units for adjustable protection.
  • Spare parts and options: MCCB Accessories, Releases & Trip Units.

How to choose

  • Frame size sets the upper current limit. Pick the smallest frame above the load.
  • Breaking capacity class (N, S, H and higher) must cover the fault level.
  • Pick thermal-magnetic for simple feeders and Ekip where selectivity or metering is needed.

FAQ

What does the S in XT2S mean?

It is the breaking capacity class of the breaker. Letters are ordered by increasing breaking capacity, and the part title lists the kA value.

What does TMD 100-1000 mean?

TMD is a thermal-magnetic trip unit. The numbers show the rated current of 100 A and the magnetic setting of 1000 A.

Can you ship Tmax XT breakers worldwide?

Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so request a quote with your part numbers and quantities.