Categories
No result found for your search.
Need help? Contact us
+90 542 203 61013
info@stoklink.com
Your cart is empty
- Home
- All Collections
- ABB Tmax XT MCCBs
Filter
ABB Tmax XT MCCBs
ABB 1SDA067450R1 XT1H 160 TMD 63-630 3p F F 63A 3-Pole Fixed Molded Case Circuit Breaker
ABB 1SDA067449R1 XT1H 160 TMD 50-500 3p F F 50A 3-Pole Fixed Molded Case Circuit Breaker
ABB 1SDA080838R1 XT1H 160 TMD 32-450 3p F F 32A 3P Fixed Power Circuit Breaker
ABB 1SDA067436R1 XT1S 160 TMD 160-1600 3p F F 160A 3-Pole Fixed Moulded Case Circuit Breaker
ABB 1SDA067435R1 XT1S 160 TMD 125-1250 3p F F 3-Pole 125A Fixed Moulded Case Circuit Breaker
ABB 1SDA067434R1 XT1S 160 TMD 100-1000 3p F F 3-Pole 100A Fixed Moulded Case Circuit Breaker
ABB 1SDA067431R1 XT1S 160 TMD 50-500 3p F F 50A 3-Pole Fixed Molded Case Circuit Breaker
ABB 1SDA067418R1 XT1N 160 TMD 160-1600 3p F F 160A 3-Pole Fixed Moulded Case Circuit Breaker
ABB 1SDA067417R1 XT1N 160 TMD 125-1250 3p F F 125A 3-Pole Fixed Moulded Case Circuit Breaker for Transformer Generator Installation Protection
ABB 1SDA067415R1 XT1N 160 TMD 80-800 3p F F 80A 3-Pole Fixed Moulded Case Circuit Breaker
ABB 1SDA067414R1 XT1N 160 TMD 63-630 3p F F 3-Pole 63A Fixed Moulded Case Circuit Breaker
ABB 1SDA067412R1 XT1N 160 TMD 40-450 3p F F 40A 3-Pole Fixed Moulded Case Circuit Breaker
ABB 1SDA067411R1 XT1N 160 TMD 32-450 3p F F 32A 3-Pole Fixed Moulded Case Circuit Breaker Tmax XT1
ABB Tmax XT MCCBs are molded case circuit breakers for feeder and motor protection from 10 A to 1600 A. The range covers 3-pole and 4-pole fixed breakers across XT1 to XT7 frames, with more than 200 products. Stoklink ships worldwide from Turkey and quotes volumes on request.
What's in this range
- XT1 to XT4 frames with TMD and TMA thermal-magnetic trip units.
- XT5 and XT6 frames for 400 A to 800 A feeders.
- Ekip electronic trip units for adjustable protection.
- Spare parts and options: MCCB Accessories, Releases & Trip Units.
How to choose
- Frame size sets the upper current limit. Pick the smallest frame above the load.
- Breaking capacity class (N, S, H and higher) must cover the fault level.
- Pick thermal-magnetic for simple feeders and Ekip where selectivity or metering is needed.
FAQ
What does the S in XT2S mean?
It is the breaking capacity class of the breaker. Letters are ordered by increasing breaking capacity, and the part title lists the kA value.
What does TMD 100-1000 mean?
TMD is a thermal-magnetic trip unit. The numbers show the rated current of 100 A and the magnetic setting of 1000 A.
Can you ship Tmax XT breakers worldwide?
Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so request a quote with your part numbers and quantities.