The Siemens 6AU1425-2AD00-0AA0 SIMOTION D425-2 DP/PN is a BASIC-performance, Drive-based motion controller that manages up to 16 axes total, including 6 axes of integrated servo or vector drive control, or 12 in V/f mode. It integrates 12 digital inputs, 16 configurable digital I/Os, 4 DRIVE-CLiQ ports, dual PROFIBUS and PROFINET interfaces, and ships with a dual fan/battery module.
This D425-2 variant is BASIC performance, so it fits machines needing up to 16 coordinated axes with millisecond-class PROFIBUS or sub-millisecond PROFINET cycle times rather than the highest-axis-count SIMOTION D4x5 models. Because drive control is integrated, built on SINAMICS S120 CU320-2 firmware, the controller and up to 6 servo axes run in the same unit without a separate SIMOTION-plus-external-drive combination, which matters when panel space or cabling budget is tight. The 16 configurable digital I/Os can each be set as DI, DO, probe input, or cam output, so one module covers both process I/O and high-speed cam-switching duties that would otherwise need a dedicated cam output card.
Coordinated multi-axis motion control in packaging, printing, and material-handling machines built on SINAMICS S120 drives with PROFINET or PROFIBUS fieldbus.
| product brand name | SIMOTION |
|---|---|
| product type designation | D425-2 DP/PN |
| Performance class for motion control system | BASIC Performance |
| Version of the motion control system | Multiple-axis system |
| number of axes / maximum | 16 |
|---|---|
| Minimum PROFIBUS cycle clock | 1 ms |
| Minimum PROFINET send cycle clock | 0.25 ms |
| Minimum interpolator cycle clock | 0.5 ms |
| Minimum servo cycle clock | 0.5 ms |
| Maximum number of axes for integrated drive control: servo | 6 |
|---|---|
| Maximum number of axes for integrated drive control: vector | 6 |
| Maximum number of axes for integrated drive control: V/f | 12 |
| Maximum number of axes for integrated drive control: note | Alternative control modes; drive control based on SINAMICS S120 CU320-2, firmware version V4.x/V5.x |
| Part number | 6AU1425-2AD00-0AA0 |
|---|---|
| Type designation | D425-2 DP/PN |
| Brand | Siemens |
| Condition | New, factory sealed |
| Source | Siemens and its authorised distributors |
| Warranty | Manufacturer warranty |
| RAM (work memory) | 78 Mbyte |
|---|---|
| Additional RAM work memory for Java applications | 20 Mbyte |
| RAM disk (load memory) | 38 Mbyte |
| Retentive memory | 364 kbyte |
| Persistent memory (user data on CF) | 1.5 Gbyte |
| Interfaces: DRIVE-CLiQ | 4 |
|---|---|
| Interfaces: USB | 2 |
| Interfaces: Industrial Ethernet | 2 |
| Interfaces: PROFIBUS | 2 |
| Interfaces: note | Equidistant and isochronous; Can be configured as master or slave |
| Interfaces: PROFINET | 1 |
| Fan | Double fan/battery module included in scope of delivery |
|---|---|
| DC supply voltage: rated value | 24 V |
| DC supply voltage: minimum | 20.4 V |
| DC supply voltage: maximum | 28.8 V |
| consumed current / typical | 1 000 mA |
| note | with no load on inputs/outputs, no 24 V supply via DRIVE-CLiQ and PROFIBUS interface |
| Making current, typ. | 5 A |
| Power loss, typ. | 24 W |
| Ambient temperature, during: long-term storage | -25 ... +55 °C |
| Ambient temperature, during: transport | -40 ... +70 °C |
| Ambient temperature, during: operation | 0 ... 55 °C |
| Ambient temperature, during: note | Maximum installation altitude 4000 m (13124 ft) above sea level. Above an altitude of 2000 m (6562 ft), the maximum ambient temperature decreases by 7 °C (12.6 °F) per 1000 m (3281 ft). |
| Relative humidity: during operation | 5 ... 95 % |
| Relative humidity: without condensation, tested acc. to IEC 60068-2-38 | Wert fehlt |
| Product property / Conformal coating | No |
| Resistance: to biologically active substances, / conformity acc. to EN 60721-3-3 | No |
| Resistance: to chemically active substances, / conformity acc. to EN 60721-3-3 | No |
| Air pressure | 620 ... 1 060 hPa |
| Degree of protection | IP20 / UL open type |
| height | 380 mm |
| width | 50 mm |
| depth | 270 mm |
| Depth / Note | When the spacer is removed 230 mm (9.05 in) deep |
| number of digital inputs | 12 |
|---|---|
| DC input voltage: rated value | 24 V |
| DC input voltage: for signal "1" | 15 ... 30 V |
| DC input voltage: for signal "0" | -3 ... +5 V |
| Electrical isolation | Yes |
| note | Yes, in groups of 6 |
| Current consumption for "1" signal level, typ. | 9 mA |
| Input delay time for: signal "0" → "1", typ. | 50 µs |
| Input delay time for: signal "1" → "0", typ. | 150 µs |
| Number of digital I/Os | 16 |
|---|---|
| Parameterization possibility of the digital I/Os | can be parameterized - as DI - as DO - as probe input (max. 16) - as cam output (max. 8) |
| DC input voltage: rated value | 24 V |
|---|---|
| DC input voltage: for signal "1" | 15 ... 30 V |
| DC input voltage: for signal "0" | -3 ... +5 V |
| Electrical isolation | No |
| Current consumption for "1" signal level, typ. | 9 mA |
| Input delay time for: signal "0" → "1", typ. | 5 µs |
| Input delay time for: signal "1" → "0", typ. | 50 µs |
| Measuring input / reproducibility | 5 µs |
| Measuring input / resolution | 1 µs |
| If used as an output / header Load voltage: rated value | 24 V |
| If used as an output / header Load voltage: minimum | 20.4 V |
| If used as an output / header Load voltage: maximum | 28.8 V |
| Current carrying capacity for each output, max. | 500 mA |
| Leakage current, max. | 2 mA |
| Output delay for: signal "0" → "1", typ. | 150 µs |
| Output delay for: signal "0" → "1", max. | 400 µs |
| Output delay for: signal "1" → "0", typ. | 75 µs |
| Output delay for: signal "1" → "0", max. | 150 µs |
| Output delay for: note | Data for Vcc = 24 V; load 48 Ohm; "1" = 90 % VOut, "0" = 10 % VOut |
| Cam output: reproducibility | 10 µs |
| Cam output: resolution | 1 µs |
| Switching frequency of the outputs for: resistive load, max. | 4 kHz |
| Switching frequency of the outputs for: inductive load, max. | 2 Hz |
| Switching frequency of the outputs for: lamp load, max. | 11 Hz |
| Short-circuit protection | Yes |
| Back-up of non-volatile data: of retentive data | unlimited buffer duration |
|---|---|
| Back-up of non-volatile data: of real-time clock, min. | 4 d |
| Back-up of non-volatile data: note | longer buffer duration of the real-time clock using a battery inserted in the double fan/battery module |
| Approvals: USA | cULus |
| Approvals: Canada | cULus |
| Approvals: Australia | RCM (formerly C-Tick) |
| Approvals: Korea | KCC |
| Approvals: Russia, Belarus and Kazakhstan | EAC |
| Shipping weight | 4.2 kg |
|---|---|
| Ships from | Türkiye |
| Dispatch | 16 Nov |
| Stock | In stock |
Source: manufacturer data · Last verified: 01 Nov 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated current of D425-2 DP/PN is 1 A.
The rated operational voltage of D425-2 DP/PN is 24 V AC.
The tariff (HS) code on file for D425-2 DP/PN is 85371091.
D425-2 DP/PN ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival. Stock items are dispatched within 1–2 business days.
A side-by-side comparison of VFD and servo drive motor type, feedback, dynamic response, overload rating, cost, and applications for industrial engineers.
Discover how Schneider soft starters reduce mechanical stress, cut energy peaks, and extend motor life across demanding industrial uses. Shop at Stoklink.
Schneider soft starters reduce energy costs by limiting inrush current, lowering demand charges, and minimizing mechanical wear on motors. Shop at Stoklink.