Siemens Air Circuit Breaker Generations: 3WA vs 3WL vs 3WT Compared
ACB Comparison of Siemens 3WA, 3WL, and 3WT generations: ratings, trip units, replacement strategy, and procurement guidance for engineers. Shop at Stoklink.
| Motor power kW | Rated current In (A) | Part number | Stock | Price |
|---|---|---|---|---|
| 630 | 3WA1106-3AB42-0AA0 | On request | $5,420.50 | |
| 800 | 3WA1108-3AB42-0AA0This part | On request | $5,573.23 | |
| 1000 | 3WA1110-3AB42-0AA0 | On request | $5,637.43 | |
| 1250 | 3WA1112-3AB42-0AA0 | On request | $6,436.15 | |
| 1600 | 3WA1116-3AB42-0AA0 | On request | $8,710.25 |
The Siemens 3WA1108-3AB42-0AA0 is a draw-out-mounted, horizontally connected 4-pole air circuit breaker in the SENTRON 3WA series, rated at 800 A continuous current with a rated breaking capacity (Icu) of 66 kA up to 500 V (50 kA at 690 V AC). It is supplied with the ETU300 LSI electronic trip unit and 2NO+2NC auxiliary contacts factory-fitted, dimensioned for main and sub-distribution switchgear operating up to 690 V.
At 800 A and frame Size I, the 3WA1108-3AB42-0AA0 carries a class breaking capacity of 66 kA (Icu, up to 500 V). The fourth (neutral) pole is switched and protected with the phases, as required on TN-C-S and TT systems where the neutral must be isolated.
The draw-out (withdrawable) design lets the 800 A breaker be racked out to an isolated position for maintenance without de-energising the busbar, suiting incomer and tie positions where continuity of supply during service is required. The shutter assembly shrouds live primary contacts when withdrawn. The ETU300 LSI trip unit provides long-time (L), short-time (S) and instantaneous (I) protection with independent settings for time-current selectivity. The factory-fitted 2NO+2NC auxiliary contacts wire directly into PLC inputs for position and status signalling.
| product brand name | SENTRON |
|---|---|
| product designation | Air circuit breaker |
| suitability for use | circuit breaker |
| size of the circuit-breaker | I |
| number of poles | 4 |
| position / of neutral conductor | neutral left |
| fastening method | withdrawable circuit breaker |
| design of the product | AC application |
| type of the driving mechanism | manual operating mechanism with mechanical or electrical closing |
| design of the electronic trip unit | ETU300 LSI |
| Weight | 87.104 kg |
| insulation voltage / rated value | 1000 V |
|---|---|
| operating voltage / at AC / at 50/60 Hz / rated value | 690 V |
| power loss [W] / maximum | 85 W |
| continuous current / rated value / maximum | 800 A |
|---|---|
| continuous current / rated value | 800 A |
| operational current: at 40 °C / rated value | 800 A |
| operational current: at 45 °C / rated value | 800 A |
| operational current: at 50 °C / rated value | 800 A |
| operational current: at 55 °C / rated value | 800 A |
| operational current: at 60 °C / rated value | 800 A |
| operational current: at 65 °C / rated value | 800 A |
| operational current: at 70 °C / rated value | 800 A |
| Part number | 3WA1108-3AB42-0AA0 |
|---|---|
| Brand | Siemens |
| Condition | New, factory sealed |
| Source | Siemens and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| ETIM class | EC000228 |
| eCl@ss | 27370409 |
| switching capacity class of the circuit breaker | S |
|---|---|
| maximum short-circuit current breaking capacity (Icu): at 500 V / rated value | 66 kA |
| maximum short-circuit current breaking capacity (Icu): at 690 V / rated value | 50 kA |
| operating short-circuit current breaking capacity (Ics): at 500 V / rated value | 66 kA |
| operating short-circuit current breaking capacity (Ics): at 690 V / rated value | 50 kA |
| short-circuit current making capacity (Icm): at 500 V / rated value | 145 kA |
| short-circuit current making capacity (Icm): at 690 V / rated value | 105 kA |
| short-time withstand current (Icw) / at 500 V AC: for 0.5 s / rated value | 66 kA |
| short-time withstand current (Icw) / at 500 V AC: for 1 s / rated value | 66 kA |
| short-time withstand current (Icw) / at 500 V AC: for 2 s / rated value | 45 kA |
| short-time withstand current (Icw) / at 500 V AC: for 3 s / rated value | 35 kA |
| short-time withstand current (Icw) / at 690 V AC: for 0.5 s / rated value | 50 kA |
| short-time withstand current (Icw) / at 690 V AC: for 1 s / rated value | 50 kA |
| short-time withstand current (Icw) / at 690 V AC: for 2 s / rated value | 45 kA |
| short-time withstand current (Icw) / at 690 V AC: for 3 s / rated value | 35 kA |
| product feature: upgradable | No |
|---|---|
| product feature: Bluetooth and USB interface | No |
| product feature: decoder for basic protection functions | Yes |
| product feature: display and function keys | No |
| product feature: SENTRON powerconfig configuration software | No |
| product feature / for L-tripping: can be switched on/off | No |
|---|---|
| product feature / for L-tripping: selectable characteristic function | No |
| product feature / for L-tripping: decoder and infinite adjustability are selectable with eSet | No |
| set values setting current (Ir) / for L-tripping / with I2t characteristic | 0.4;0.5;0.6;0.7;0.75;0.8;0.85;0.9;0.95;1 |
| reference value setting current (Ir) / for L-tripping / with I2t characteristic | x In |
| set values delay time (tr) / for L-tripping / with I2t characteristic | 0.75;1;2;5;8;10;14;17;21;25 |
| reference value delay time (tr) / for L-tripping / with I2t characteristic | s |
| product feature / with neutral conductor protection / can be switched on/off | No |
|---|---|
| setting values setting current (InN) / for N-tripping | 1 |
| reference value setting current (InN) / for N-tripping | x In |
| S: delayed short-circuit protection ST product feature / for S-tripping: independent of direction / can be switched on/off | Yes |
| set values setting current (Isd) / for S-tripping / with I0t characteristic | 1.5;2;2.5;3;4;5;6;8;10 |
|---|---|
| reference value setting current (Isd) / for S-tripping / with I0t characteristic | x Ir |
| set values delay time (tsd) / for S-tripping / with I0t characteristic | 0.08;0.15;0.22;0.3;0.4 |
| reference value delay time (tsd) / for S-tripping / with I0t characteristic | s |
| set values setting current (Isd) / for S-tripping / with I2t characteristic | 1.5;2;2.5;3;4;5;6;8;10 |
|---|---|
| reference value setting current (Isd) / for S-tripping / with I2t characteristic | x Ir |
| set values delay time (tsd) / for S-tripping / with I2t characteristic | 0.08;0.15;0.22;0.3;0.4 |
| product feature / for I-tripping: can be switched on/off | No |
| product feature / for I-tripping: decoder and infinite adjustability are selectable (with eSet) | No |
| set values setting current (Ii) / for I-tripping | 1.5;2;3;4;5;6;8;10;12;15 |
| reference value setting current (Ii) / for I-tripping | x In |
| product feature / for G-tripping: selectable characteristic function | No |
|---|
| protection function: maintenance mode DAS+ | Yes |
|---|
| measurement function: current measurement | Yes |
|---|
| communication function | No |
|---|
| mechanical service life (operating cycles): without support / typical | 15000 |
|---|---|
| mechanical service life (operating cycles): with support / typical | 30000 |
| electrical endurance (operating cycles): at 690 V / without support / typical | 10000 |
| electrical endurance (operating cycles): at 690 V / with support / typical | 30000 |
| height | 468 mm |
|---|---|
| width | 410 mm |
| depth | 471 mm |
| arrangement of electrical connectors / for main current circuit | main connection on the rear, horizontal |
|---|
| design of the auxiliary switch | 2 NO + 2 NC |
|---|---|
| number of NC contacts / for auxiliary contacts | 2 |
| number of NO contacts / for auxiliary contacts | 2 |
| number of CO contacts / for auxiliary contacts | 0 |
| product component: undervoltage release | No |
|---|---|
| product component: voltage trigger | No |
| product component: trip indicator | Yes |
| product component: motor drive | No |
| protection class IP / on the front | IP20 |
|---|---|
| ambient temperature / during operation: minimum | -40 °C |
| ambient temperature / during operation: maximum | 70 °C |
| ambient temperature / during storage: minimum | -40 °C |
| ambient temperature / during storage: maximum | 80 °C |
| reference code / according to IEC 81346-2 | Q |
|---|
| Environment General Product Approval | Radio Equipment |
|---|---|
| General Product Approval EMV Type Approval Certi- Test Certificates | ficate |
| Net weight | 74.104 kg |
|---|---|
| Country of origin | CZ |
| Shipping weight | 79.104 kg |
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 30 Oct 2026
No documents are on file for this part yet.
Ask us for the datasheet| Motor power | Rated current | Part number | Model no | Stock | Dispatch | Price | Add to cart |
|---|---|---|---|---|---|---|---|
| 630 A | 3WA1106-3AB42-0AA0 | 3WA | On request | — | $5,420.50 | Quote | |
| 800 A | 3WA1108-3AB42-0AA0 This part | 3WA | On request | — | $5,573.23 | Quote | |
| 1000 A | 3WA1110-3AB42-0AA0 | 3WA | On request | — | $5,637.43 | Quote | |
| 1250 A | 3WA1112-3AB42-0AA0 | 3WA | On request | — | $6,436.15 | Quote | |
| 1600 A | 3WA1116-3AB42-0AA0 | 3WA | On request | — | $8,710.25 | Quote | |
| 2000 A | 3WA1120-3AB42-0AA0 | 3WA | On request | — | $9,468.67 | Quote | |
| 2500 A | 3WA1225-3AB42-0AA0 | 3WA | On request | — | $11,298.64 | Quote | |
| 3200 A | 3WA1232-3AB42-0AA0 | 3WA | On request | — | $12,417.00 | Quote | |
| 4000 A | 3WA1240-3AB42-0AA0 | 3WA | On request | — | $16,578.45 | Quote |
The rated current of 3WA1108-3AB42-0AA0 is 800 A.
The rated operational voltage of 3WA1108-3AB42-0AA0 is 690 V AC.
3WA1108-3AB42-0AA0 ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.
ACB Comparison of Siemens 3WA, 3WL, and 3WT generations: ratings, trip units, replacement strategy, and procurement guidance for engineers. Shop at Stoklink.
Compare 1600-2500A ACB platforms: ABB Emax 2, Schneider MTZ2, Siemens 3WL2 on breaking capacity, trip units, endurance and lifecycle cost. Shop at Stoklink.
ABB Emax 2 air circuit breaker selection, sizing, trip units, selectivity, and maintenance guide for 630 to 6300 A LV switchgear engineers. Shop at...