Schneider Zelio vs ABB CM: Monitoring Relay Comparison
A function-by-function comparison of Schneider Zelio Control and ABB CM monitoring relays covering three-phase supply, voltage, current, level, temperature, module width, and measurement method.
The Siemens 3UG5514-1BR20 is a relay from the SENTRON/SIRIUS 3UG5 series. Analog adjustment monitoring relay phase failure, phase sequence, asymmetry and under-voltage monitoring 3x 160-690 V AC, 15-70 Hz 2 changeover contacts screw terminal. Supplied by Stoklink for industrial and commercial low-voltage applications.
The Siemens 3UG5514-1BR20 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3UG5 range it integrates with compatible SENTRON/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.
| product brand name | SIRIUS |
|---|---|
| product designation | Network monitoring relay with analog setting |
| design of the product | monitoring of phase sequence, phase failure, phase asymmetry, and undervoltage |
| product type designation | 3UG5 |
| product function | line monitoring |
|---|---|
| display version LED | Yes |
| design of the display | LED |
| power loss [W] maximum | 1.8 W |
| power loss [V·A] maximum | 5.1 V·A |
| insulation voltage for overvoltage category III according to IEC 60664: with degree of pollution 2 rated value | 690 V |
| degree of pollution | 3 |
| type of voltage: for monitoring | AC |
| type of voltage: of the operating voltage for actuation | AC/DC |
| surge voltage resistance rated value | 6 kV |
| shock resistance according to IEC 60068-2-27 | sinusoidal half-wave 15 g / 11 ms |
| vibration resistance according to IEC 60068-2-6 | 10 ... 55 Hz: 0.35 mm |
| switching behavior | monostable |
| mechanical service life (operating cycles) typical | 10 000 000 |
| electrical endurance (operating cycles) at AC-15 at 230 V typical | 100 000 |
| thermal current of the switching element with contacts maximum | 5 A |
| reference code according to IEC 81346-2 | K |
| relative repeat accuracy | 0% |
| Substance Prohibitance (day/month/year) | 06/01/2023 |
| SVHC substance name | Lead CAS-No. 7439-92-1 Lead monoxide (lead oxide) CAS-No. 1317-36-8 2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-No. 71868- 10-5 Melamine CAS-No. 108-78-1 6,6'-di-tert-butyl-2,2'-methylenedi-p-cresol CAS-No. 119-47-1 |
| product function: undervoltage detection | Yes |
|---|---|
| product function: overvoltage detection | No |
| product function: phase sequence recognition | Yes |
| product function: phase failure detection | Yes |
| product function: asymmetry detection | Yes |
| product function: overcurrent detection 1 phase | No |
| product function: overvoltage detection 3 phase | No |
| product function: undercurrent detection 1 phase | No |
| product function: undervoltage detection 3 phases | Yes |
| product function: voltage window recognition 3 phase | No |
| product function: adjustable open/closed-circuit current principle | No |
| product function: auto-RESET | Yes |
| product function: neutral conductor monitoring adjustable | No |
| suitability for use safety-related circuits | No |
| Part number | 3UG5514-1BR20 |
|---|---|
| Type designation | 3UG5 |
| Brand | Siemens |
| Condition | New, factory sealed |
| Source | Siemens and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| EAN | 4047621099927 |
| ETIM class | EC001441 |
| eCl@ss | 27371803 |
| type of voltage of the control supply voltage | AC |
|---|---|
| control supply voltage 1 at AC: at 50 Hz | 200 ... 690 V |
| control supply voltage 1 at AC: at 60 Hz | 200 ... 690 V |
| operating range factor control supply voltage rated value at AC at 50 Hz: initial value | 0.85 |
| supply voltage frequency rated value | 70 ... 15 Hz |
|---|
| design of the interface bluetooth | No |
|---|
| measurable voltage 1 at AC | 160 ... 760 V |
|---|---|
| measurable voltage 2 at AC | 160 ... 760 V |
| adjustable operating delay time initial value | 0.1 s |
| adjustable response delay time: with lower or upper limit violation | 0.1 ... 20 s |
| buffering time in the event of power failure minimum | 20 ms |
| response time maximum | 500 ms |
| relative temperature-related measurement deviation | 1% |
| relative metering precision | 5% |
|---|---|
| temperature drift per °C | 0 %/°C |
| design of the fuse link: for short-circuit protection of the NO contacts of the relay outputs required | gL/gG: 6 A or MCB type C: 1 A |
|---|
| protocol is supported IO-Link protocol | No |
|---|---|
| type of voltage supply via input/output link master | No |
| material of switching contacts | AgSnO2 |
|---|---|
| number of NC contacts delayed switching | 0 |
| number of NO contacts delayed switching | 0 |
| number of CO contacts: for auxiliary contacts | 2 |
| number of CO contacts: delayed switching | 2 |
| operating frequency with 3RT2 contactor maximum | 5 000 1/h |
| contact reliability of auxiliary contacts | one incorrect switching operation of 100 million switching operations (17 V, 5 mA) |
| contact rating of auxiliary contacts according to UL | R300 / B300 |
| number of poles for main current circuit | 3 |
|---|---|
| ampacity of the output relay at AC-15: at 250 V at 50/60 Hz | 3 A |
| ampacity of the output relay at AC-15: at 400 V at 50/60 Hz | 3 A |
| ampacity of the output relay at DC-13: at 24 V | 1 A |
| ampacity of the output relay at DC-13: at 110 V | 0.2 A |
| ampacity of the output relay at DC-13: at 125 V | 0 A |
| ampacity of the output relay at DC-13: at 230 V | 0.1 A |
| ampacity of the output relay at DC-13: at 250 V | 0 A |
| operational current at 17 V minimum | 5 mA |
| continuous current of the DIAZED fuse link of the output relay | 6 A |
| EMC emitted interference according to IEC 60947-1 | class A |
|---|---|
| conducted interference: due to burst according to IEC 61000-4-4 | 2 kV (power ports), 2 kV (signal ports) |
| conducted interference: due to conductor-earth surge according to IEC 61000-4-5 | 2 kV |
| conducted interference: due to conductor-conductor surge according to IEC 61000-4-5 | 1 kV |
| field-based interference according to IEC 61000-4-3 | 10 V/m |
| electrostatic discharge according to IEC 61000-4-2 | 6 kV contact discharge / 8 kV air discharge |
| design of the electrical isolation | galvanic isolation |
|---|---|
| galvanic isolation: between input and output | Yes |
| galvanic isolation: between the outputs | Yes |
| galvanic isolation: between the voltage supply and other circuits | Yes |
| protection class IP on the front according to IEC 60529 | IP20 |
|---|
| product component removable terminal for main circuit | Yes |
|---|---|
| product component removable terminal for auxiliary and control circuit | Yes |
| type of electrical connection | screw terminal |
| design of terminals with cross-head screw | PZ 1 |
| type of connectable conductor cross-sections: solid | 1x (0.5 ... 4 mm2), 2x (0.5 ... 2.5 mm2) |
| type of connectable conductor cross-sections: finely stranded with core end processing | 1x (0.5 ... 4 mm2), 2x (0.5 ... 2.5 mm2) |
| type of connectable conductor cross-sections: for AWG cables solid | 1x (20 ... 12), 2x (20 ... 14) |
| connectable conductor cross-section: solid | 0.5 ... 4 mm2 |
| connectable conductor cross-section: finely stranded with core end processing | 0.5 ... 4 mm2 |
| AWG number as coded connectable conductor cross section: solid | 20 ... 12 |
| AWG number as coded connectable conductor cross section: stranded | 20 ... 12 |
| tightening torque with screw-type terminals | 0.6 ... 0.8 N·m |
| stripped length | 10 mm |
| mounting position | any |
|---|---|
| fastening method | screw and snap-on mounting onto 35 mm DIN rail |
| height | 100 mm |
| width | 22.5 mm |
| depth | 90 mm |
| with side-by-side mounting: forwards | 0 mm |
| with side-by-side mounting: backwards | 0 mm |
| with side-by-side mounting: upwards | 0 mm |
| with side-by-side mounting: downwards | 0 mm |
| with side-by-side mounting: at the side | 0 mm |
| for grounded parts: forwards | 0 mm |
| for grounded parts: backwards | 0 mm |
| for grounded parts: upwards | 0 mm |
| for grounded parts: at the side | 0 mm |
| for grounded parts: downwards | 0 mm |
| for live parts: forwards | 0 mm |
| for live parts: backwards | 0 mm |
| for live parts: upwards | 0 mm |
| for live parts: downwards | 0 mm |
| for live parts: at the side | 0 mm |
| installation altitude at height above sea level maximum | 2 000 m |
|---|---|
| ambient temperature: during operation | -25 ... +60 °C |
| ambient temperature: during storage | -40 ... +85 °C |
| ambient temperature: during transport | -40 ... +85 °C |
| relative humidity during operation maximum | 70 % |
| Environmental Product Declaration: global warming potential [CO2 eq] / during manufacturing | 5.65 kg |
|---|
| Net weight | 0.146 kg |
|---|---|
| Package dimensions | 129 × 105 × 38 mm |
| Country of origin | DE |
| Shipping weight | 0.646 kg |
| Dispatch | 25 Nov |
| Stock | Low stock |
Source: manufacturer data · Last verified: 31 Oct 2026
The rated current of 3UG5 is 5 A.
The rated operational voltage of 3UG5 is 690 V AC.
The control voltage range of 3UG5 is 200–690 V.
The tariff (HS) code on file for 3UG5 is 85364900.
The EAN (GTIN) of 3UG5 is 4047621099927.
3UG5 ships worldwide by express courier, with tracking. Shipping and import duties calculated at checkout · nothing to pay on delivery. Stock items are dispatched within 1–2 business days.
A function-by-function comparison of Schneider Zelio Control and ABB CM monitoring relays covering three-phase supply, voltage, current, level, temperature, module width, and measurement method.
A step-by-step selection guide for phase and voltage monitoring relays, covering function match, auxiliary supply, threshold setting, output logic, and Schneider vs ABB CM...
How conductive level monitoring relays detect liquid presence, size sensitivity for the medium, and control pump up/down cycles with dry-run protection.