- Home
- All Products
- 3RW5236-6AC14, Soft Starter, 90 kW, 171 A, 200 to 480V AC 3RW5236-6AC14, Soft Starter, 90 kW, 171 A, 200 to 480V AC
3RW5236-6AC14, Soft Starter, 90 kW, 171 A, 200 to 480V AC
$2,071.00
- Description
Siemens 3RW52 Soft Starter Series – Overview
Siemens 3RW52 soft starters are high-performance motor starting solutions designed for demanding industrial applications requiring precise and reliable control of three-phase asynchronous motors. The 3RW52 series focuses on reducing mechanical stress, limiting inrush current, and supporting higher motor power ratings with advanced protection functions compared to compact soft starters. With robust construction and enhanced motor protection capabilities, Siemens 3RW52 soft starters are well suited for heavy-duty applications such as large pumps, compressors, conveyors, mixers, and industrial process machinery where dependable motor starting and operational reliability are critical.
Product Description: 3RW5236-6AC14
The Siemens 3RW5236-6AC14 is a SIRIUS 3RW52 soft starter rated for 171 A nominal current and specified for a motor power of 90 kW at 400 V (direct/delta wiring). It accepts a mains supply voltage range of 200–480 V AC and is designed for 50/60 Hz industrial power systems. Typical motor compatibilities include three-phase asynchronous motors up to the stated 90 kW rating (with higher equivalent ratings when configured in inside-delta — 160 kW is commonly specified for inside-delta use). This unit uses standard soft-start control modes (ramp-up and ramp-down) and provides adjustable current limiting and soft-torque start/stop behaviour to reduce mechanical stress and inrush current in large pumps, fans, compressors and conveyor drives. The 3RW5236-6AC14 also includes motor protection functions such as electronic overload protection and thermistor (PTC) evaluation and offers an analog monitoring output (4…20 mA / 0…10 V selectable) for integration into local control or PLC systems. The control supply for the unit’s coil is 110–250 V AC. With an IP00 enclosure as supplied, this model is intended for panel or cubicle mounting where environmental protection and a bypass cover or cabinet are provided.
Key Soft Starter Attributes
| Rated operational current (Ie) | 171 A |
|---|---|
| Motor power range | 90 kW at 400 V (direct); 160 kW inside-delta |
| Supply voltage | 200 – 480 V AC (50/60 Hz) |
| Control method | Ramp-up / Ramp-down; adjustable current limitation and soft torque |
| Motor protection functions | Electronic overload protection; thermistor (PTC) evaluation |
| Communication interfaces | Analog output (4…20 mA default / 0…10 V selectable) |
| Enclosure / protection class | IP00 |