How to Select and Size a Soft Starter for a Motor
How to size a soft starter correctly by full-load current, IEC 60947-4-2 duty class, starting torque against the load, control method, wiring topology and...
Siemens 3RW30 soft starters are compact and cost-effective motor starting solutions designed for basic soft starting of three-phase asynchronous motors in standard industrial applications. The 3RW30 series focuses on reducing mechanical stress and limiting inrush current during motor start-up, providing a simple and reliable alternative to direct-on-line starting. With a straightforward design and easy commissioning, Siemens 3RW30 soft starters are well suited for pumps, fans, compressors, conveyors, and other simple motor-driven machines where basic motor starting control is sufficient.
The Siemens 3RW3036-1BB14 is a SIRIUS 3RW30 series motor soft starter rated for 45 A continuous current and specified for motors up to 22 kW at 400 V (11 kW at 230 V). The main supply voltage range is 200–480 V AC, making this unit suitable for standard three-phase industrial supplies. Control power for the device accepts 110–230 V AC/DC. The starter uses phase-angle (variable phase) control with a ramp-like voltage increase to limit inrush current and reduce mechanical stress during starts. It includes an integrated bypass contactor to minimise dissipation once the motor is at full speed and provides basic motor overload protection. Typical applications are pumps, fans, compressors and conveyors where straightforward, economical motor soft starting is required and a compact S2-size device is preferred. This SKU is supplied with screw terminals and a compact footprint for panel mounting.
| product brand name | SIRIUS |
|---|---|
| product designation | Soft starter |
| product feature: integrated bypass contact system | Yes |
| product feature: thyristors | Yes |
| product function: intrinsic device protection | No |
| product function: motor overload protection | No |
| product function: evaluation of thermistor motor protection | No |
| product function: external reset | No |
| product function: adjustable current limitation | No |
| product function: inside-delta circuit | No |
| product component motor brake output | No |
| insulation voltage rated value | 600 V |
| degree of pollution | 3, acc. to IEC 60947-4-2 |
| blocking voltage of the thyristor maximum | 1 600 V |
| reference code according to EN 61346-2 | Q |
| reference code according to DIN 40719 extended according to IEC 204-2 according to IEC 750 | G |
| operational current: at 40 °C rated value | 45 A |
|---|---|
| operational current: at 50 °C rated value | 42 A |
| operational current: at 60 °C rated value | 39 A |
| at 230 V: at standard circuit at 40 °C rated value | 11 kW |
| at 400 V: at standard circuit at 40 °C rated value | 22 kW |
| yielded mechanical performance [hp] for 3-phase AC motor at 200/208 V at standard circuit at 50 °C rated value | 10 hp |
| operating frequency rated value | 50 ... 60 Hz |
| relative negative tolerance of the operating frequency | -10 % |
| relative positive tolerance of the operating frequency | 10 % |
| operating voltage at standard circuit rated value | 200 ... 480 V |
| relative negative tolerance of the operating voltage at standard circuit | -15 % |
| relative positive tolerance of the operating voltage at standard circuit | 10 % |
| minimum load [%] | 10 % |
| continuous operating current [% of Ie] at 40 °C | 115 % |
| power loss [W] at operational current at 40 °C during operation typical | 6 W |
| type of voltage of the control supply voltage | AC/DC |
|---|---|
| control supply voltage frequency 1 rated value | 50 Hz |
| control supply voltage frequency 2 rated value | 60 Hz |
| relative negative tolerance of the control supply voltage frequency | -10 % |
| relative positive tolerance of the control supply voltage frequency | 10 % |
| control supply voltage 1 at AC at 50 Hz | 110 ... 230 V |
| control supply voltage 1 at AC at 60 Hz | 110 ... 230 V |
| relative negative tolerance of the control supply voltage at AC at 50 Hz | -15 % |
| relative positive tolerance of the control supply voltage at AC at 50 Hz | 10 % |
| control supply voltage 1 at DC | 110 ... 230 V |
| display version for fault signal | red |
| Part number | 3RW3036-1BB14 |
|---|---|
| Brand | Siemens |
| Condition | New, factory sealed |
| Source | Siemens and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| EAN | 4011209719279 |
| ETIM class | EC000640 |
| eCl@ss | 27370907 |
| size of engine control device | S2 |
|---|---|
| width | 55 mm |
| height | 160 mm |
| depth | 170 mm |
| fastening method | screw and snap-on mounting |
| mounting position | With vertical mounting surface +/-10° rotatable, with vertical mounting surface +/- 10° tiltable to the front and back |
| required spacing with side-by-side mounting: upwards | 60 mm |
| required spacing with side-by-side mounting: at the side | 30 mm |
| required spacing with side-by-side mounting: downwards | 40 mm |
| wire length maximum | 300 m |
| number of poles for main current circuit | 3 |
| type of electrical connection: for main current circuit | screw-type terminals |
|---|---|
| type of electrical connection: for auxiliary and control circuit | screw-type terminals |
| number of NC contacts for auxiliary contacts | 0 |
| number of NO contacts for auxiliary contacts | 1 |
| number of CO contacts for auxiliary contacts | 0 |
| type of connectable conductor cross-sections for main contacts for box terminal using the front clamping point: finely stranded with core end processing | 1.5 ... 25 mm2 |
| type of connectable conductor cross-sections for AWG cables for main contacts for box terminal: using the back clamping point | 16 ... 2 |
| type of connectable conductor cross-sections for auxiliary contacts: solid | 2x (0.5 ... 2.5 mm2) |
| installation altitude at height above sea level | 5 000 m |
|---|---|
| environmental category: during transport according to IEC 60721 | 2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m) |
| environmental category: during storage according to IEC 60721 | 1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4 |
| environmental category: during operation according to IEC 60721 | 3K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6 |
| ambient temperature: during operation | -25 ... +60 °C |
| ambient temperature: during storage | -40 ... +80 °C |
| derating temperature | 40 °C |
| protection class IP on the front according to IEC 60529 | IP20 |
| touch protection on the front according to IEC 60529 | finger-safe, for vertical contact from the front |
| at 220/230 V: at standard circuit at 50 °C rated value | 15 hp |
|---|---|
| at 460/480 V: at standard circuit at 50 °C rated value | 30 hp |
| contact rating of auxiliary contacts according to UL | B300 / R300 |
| Environmental Product Declaration: global warming potential [CO2 eq] / during manufacturing | 22 kg |
|---|
| Net weight | 1.159 kg |
|---|---|
| Package dimensions | 195 × 74 × 168 mm |
| Country of origin | CZ |
| Shipping weight | 1.659 kg |
| Ships from | Türkiye |
| Dispatch | 12 Nov |
| Stock | In stock |
Source: manufacturer data · Last verified: 30 Oct 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated current of 3RW3036-1BB14 is 45 A.
The rated operational voltage of 3RW3036-1BB14 is 200–480 V AC.
The rated motor power of 3RW3036-1BB14 is 22 kW.
The control voltage range of 3RW3036-1BB14 is 110–230 V.
The tariff (HS) code on file for 3RW3036-1BB14 is 853710.
The EAN (GTIN) of 3RW3036-1BB14 is 4011209719279.
3RW3036-1BB14 ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival. Stock items are dispatched within 1–2 business days.
How to size a soft starter correctly by full-load current, IEC 60947-4-2 duty class, starting torque against the load, control method, wiring topology and...
A side-by-side comparison of soft starters and autotransformer (Korndorfer) starters covering torque, supply-side current, transition type, maintenance, cost, and load fit.
Explore the different types of soft starters, from analog to digital and solid-state models, with key features for industrial motor control. Shop at Stoklink.