Siemens 3RW30 soft starters are compact and cost-effective motor starting solutions designed for basic soft starting of three-phase asynchronous motors in standard industrial applications. The 3RW30 series focuses on reducing mechanical stress and limiting inrush current during motor start-up, providing a simple and reliable alternative to direct-on-line starting. With a straightforward design and easy commissioning, Siemens 3RW30 soft starters are well suited for pumps, fans, compressors, conveyors, and other simple motor-driven machines where basic motor starting control is sufficient.
The Siemens 3RW3014-1BB14 is a SIRIUS 3RW30 series soft starter rated for 6.5 A (at 40 °C) with motor output ratings up to 3 kW at 400 V (and 1.5 kW at 230 V in the standard circuit). It is designed for three-phase supply voltages from 200 to 480 V AC and accepts a control/auxiliary voltage of 110–230 V AC/DC. The unit uses thyristor-based soft starting with an integrated bypass contact system to reduce heating and losses after start-up, and it is specified for operation on 50–60 Hz networks.
Typical motor compatibility covers small industrial motors in the 1.5–3 kW range (depending on system voltage and ambient temperature). This model is appropriate for straightforward industrial motor starting tasks such as small pumps, fans, compressors and conveyors where simple soft-start functionality and compact footprint are required. Notable verified features for this SKU include the integrated bypass contact system and thyristor power stage. The device does not provide intrinsic motor overload protection; external overload or motor protection must be used where required by the application.
Practical notes for procurement and installation: the rated operational current falls with increased ambient temperature (manufacturer ratings specify 6 A at 50 °C and 5.5 A at 60 °C), so select the correct size when ambient conditions or duty cycle impose additional thermal stress. The 3RW3014-1BB14 is intended as a low-cost, easy-to-commission soft starter for engineers and maintenance teams who need controlled starting current and reduced mechanical shock without advanced communication or integrated motor protection.
| product brand name | SIRIUS |
|---|---|
| product designation | Soft starter |
| product feature: integrated bypass contact system | Yes |
| product feature: thyristors | Yes |
| product function: intrinsic device protection | No |
| product function: motor overload protection | No |
| product function: evaluation of thermistor motor protection | No |
| product function: external reset | No |
| product function: adjustable current limitation | No |
| product function: inside-delta circuit | No |
| product component motor brake output | No |
| insulation voltage rated value | 600 V |
| degree of pollution | 3, acc. to IEC 60947-4-2 |
| blocking voltage of the thyristor maximum | 1 200 V |
| reference code according to EN 61346-2 | Q |
| reference code according to DIN 40719 extended according to IEC 204-2 according to IEC 750 | G |
| operational current: at 40 °C rated value | 6.5 A |
|---|---|
| operational current: at 50 °C rated value | 6 A |
| operational current: at 60 °C rated value | 5.5 A |
| at 230 V: at standard circuit at 40 °C rated value | 1.5 kW |
| at 400 V: at standard circuit at 40 °C rated value | 3 kW |
| yielded mechanical performance [hp] for 3-phase AC motor at 200/208 V at standard circuit at 50 °C rated value | 1 hp |
| operating frequency rated value | 50 ... 60 Hz |
| relative negative tolerance of the operating frequency | -10 % |
| relative positive tolerance of the operating frequency | 10 % |
| operating voltage at standard circuit rated value | 200 ... 480 V |
| relative negative tolerance of the operating voltage at standard circuit | -15 % |
| relative positive tolerance of the operating voltage at standard circuit | 10 % |
| minimum load [%] | 10 % |
| continuous operating current [% of Ie] at 40 °C | 115 % |
| power loss [W] at operational current at 40 °C during operation typical | 0.5 W |
| type of voltage of the control supply voltage | AC/DC |
|---|---|
| control supply voltage frequency 1 rated value | 50 Hz |
| control supply voltage frequency 2 rated value | 60 Hz |
| relative negative tolerance of the control supply voltage frequency | -10 % |
| relative positive tolerance of the control supply voltage frequency | 10 % |
| control supply voltage 1 at AC at 50 Hz | 110 ... 230 V |
| control supply voltage 1 at AC at 60 Hz | 110 ... 230 V |
| relative negative tolerance of the control supply voltage at AC at 50 Hz | -15 % |
| relative positive tolerance of the control supply voltage at AC at 50 Hz | 10 % |
| control supply voltage 1 at DC | 110 ... 230 V |
| display version for fault signal | red |
| Part number | 3RW3014-1BB14 |
|---|---|
| Brand | Siemens |
| Condition | New, factory sealed |
| Source | Siemens and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| EAN | 4011209719606 |
| ETIM class | EC000640 |
| eCl@ss | 27370907 |
| size of engine control device | S00 |
|---|---|
| width | 45 mm |
| height | 95 mm |
| depth | 150 mm |
| fastening method | screw and snap-on mounting |
| mounting position | With vertical mounting surface +/-10° rotatable, with vertical mounting surface +/- 10° tiltable to the front and back |
| required spacing with side-by-side mounting: upwards | 60 mm |
| required spacing with side-by-side mounting: at the side | 15 mm |
| required spacing with side-by-side mounting: downwards | 40 mm |
| wire length maximum | 300 m |
| number of poles for main current circuit | 3 |
| type of electrical connection: for main current circuit | screw-type terminals |
|---|---|
| type of electrical connection: for auxiliary and control circuit | screw-type terminals |
| number of NC contacts for auxiliary contacts | 0 |
| number of NO contacts for auxiliary contacts | 1 |
| number of CO contacts for auxiliary contacts | 0 |
| type of connectable conductor cross-sections for main contacts for box terminal using the front clamping point: finely stranded with core end processing | 2x (1 ... 2.5 mm2), 2x (2.5 ... 6 mm2) |
| type of connectable conductor cross-sections for AWG cables for main contacts for box terminal: using the front clamping point | 2x (16 ... 10) |
| type of connectable conductor cross-sections for auxiliary contacts: solid | 2x (0.25 ... 2.5 mm2) |
| installation altitude at height above sea level | 5 000 m |
|---|---|
| environmental category: during transport according to IEC 60721 | 2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m) |
| environmental category: during storage according to IEC 60721 | 1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4 |
| environmental category: during operation according to IEC 60721 | 3K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6 |
| ambient temperature: during operation | -25 ... +60 °C |
| ambient temperature: during storage | -40 ... +80 °C |
| derating temperature | 40 °C |
| protection class IP on the front according to IEC 60529 | IP20 |
| touch protection on the front according to IEC 60529 | finger-safe, for vertical contact from the front |
| at 220/230 V: at standard circuit at 50 °C rated value | 1 hp |
|---|---|
| at 460/480 V: at standard circuit at 50 °C rated value | 3 hp |
| contact rating of auxiliary contacts according to UL | B300 / R300 |
| Environmental Product Declaration: global warming potential [CO2 eq] / during manufacturing | 11.1 kg |
|---|
| Net weight | 0.446 kg |
|---|---|
| Package dimensions | 126 × 57 × 165 mm |
| Country of origin | CZ |
| Shipping weight | 0.946 kg |
| Ships from | Türkiye |
| Dispatch | 12 Nov |
| Stock | In stock |
Source: manufacturer data · Last verified: 30 Oct 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated current of 3RW3014-1BB14 is 6.5 A.
The rated operational voltage of 3RW3014-1BB14 is 200–480 V AC.
The rated motor power of 3RW3014-1BB14 is 3 kW.
The control voltage range of 3RW3014-1BB14 is 110–230 V.
The tariff (HS) code on file for 3RW3014-1BB14 is 853710.
The EAN (GTIN) of 3RW3014-1BB14 is 4011209719606.
3RW3014-1BB14 ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival. Stock items are dispatched within 1–2 business days.
How to size a soft starter correctly by full-load current, IEC 60947-4-2 duty class, starting torque against the load, control method, wiring topology and...
A side-by-side comparison of soft starters and autotransformer (Korndorfer) starters covering torque, supply-side current, transition type, maintenance, cost, and load fit.
Explore the different types of soft starters, from analog to digital and solid-state models, with key features for industrial motor control. Shop at Stoklink.