- Home
- All Products
- Siemens 1FK7062-2AC71-1QA0 SIMOTICS S 1FK7-CT 1.5kW 8.5Nm 2000rpm Servo Motor Siemens 1FK7062-2AC71-1QA0 SIMOTICS S 1FK7-CT 1.5kW 8.5Nm 2000rpm Servo Motor
Siemens 1FK7062-2AC71-1QA0 SIMOTICS S 1FK7-CT 1.5kW 8.5Nm 2000rpm Servo Motor
Get Quote
- Description
The Siemens 1FK7062-2AC71-1QA0 is a SIMOTICS S 1FK7-CT synchronous servo motor rated 1.5 kW, 8.5 Nm standstill torque (M0, 100K), and 2000 rpm rated speed at 600 VDC bus voltage. It is naturally cooled, IMB5-mounted, and fitted with a DRIVE-CLiQ absolute single-turn 20-bit encoder (AS20DQI); this order number ships without a holding brake.
Technical Specifications
| SKU | 1FK7062-2AC71-1QA0 |
| Brand | Siemens |
| Series | SIMOTICS S |
| Product Designation | 1FK7-CT |
| Rated Power (PN) | 1.5 kW |
| DC Bus Voltage (UDC) | 600 V |
| Standstill Torque (M0, 100K) | 8.5 Nm |
| Rated Speed (NN) | 2000 rpm |
| Optimum Speed | 2,000 rpm |
| Number of Poles | 8 |
| Rated Current | 2.6 A |
| Moment of Inertia | 11.200 kgcm² |
| Efficiency | 90.0 % |
| Torque Constant | 2.83 Nm/A |
| Voltage Constant (20°C) | 180.5 V/1000 min⁻¹ |
| Winding Resistance (20°C) | 3.59 Ω |
| Rotating Field Inductance | 45.5 mH |
| Electrical Time Constant | 12.70 ms |
| Mechanical Time Constant | 1.51 ms |
| Thermal Time Constant | 35 min |
| Shaft Torsional Stiffness | 37,000 Nm/rad |
| Shaft Height | 63 mm |
| Mounting | IMB5 (IM V1, IM V3), Flange 1 |
| Cooling | Natural cooling |
| Radial Runout Tolerance | 0.040 mm |
| Concentricity Tolerance | 0.10 mm |
| Axial Runout Tolerance | 0.10 mm |
| Degree of Protection | IP64 |
| Encoder | Absolute single-turn 20-bit, DRIVE-CLiQ (AS20DQI) |
| Shaft | Parallel key, tolerance N |
| Holding Brake | Without holding brake |
| Housing Color | Anthracite (RAL 7016) |
| Net Weight | 9.1 kg |
Selection Notes
This 1FK7062-2AC71 winding is the lowest-speed option offered in the 1FK7062 frame, at 2000 rpm with a 2.83 Nm/A torque constant, so it needs only 2.6 A rated current for 8.5 Nm standstill torque. It ships without a holding brake, at 11.200 kgcm² moment of inertia and 37,000 Nm/rad shaft torsional stiffness. Faster windings are also available in the same frame at a lower torque constant; choose this one when minimizing drive current draw matters more than base speed. The 45.5 mH rotating field inductance and 3.59 Ω winding resistance both reflect the higher-turns winding needed to reach this low base speed, so size the drive's current-loop bandwidth accordingly.
Applications
Natural (fan-less) cooling and IP64 protection suit compact machine enclosures without forced airflow. The DRIVE-CLiQ interface connects directly to SINAMICS S120/S210 drive systems over a single feedback cable. At 8.5 Nm standstill torque and a 2000 rpm rated speed, it fits direct-drive or low-ratio-geared axes where torque, not speed, dominates the duty cycle.