- Schneider Electric TPRST025 TeSys Island TPRST 25A 3P 11kW DOL Motor Starter Module Schneider Electric TPRST025 TeSys Island TPRST 25A 3P 11kW DOL Motor Starter Module
Schneider Electric TPRST025 TeSys Island TPRST 25A 3P 11kW DOL Motor Starter Module
Schneider Electric TPRST025 TeSys Island TPRST 25A 3P 11kW DOL Motor Starter Module
Get Quote
- Description
The Schneider Electric TPRST025 is a TeSys island direct-on-line motor starter (device short name TPRST) rated 25 A (AC-3) at up to 440 V, for motors up to 11 kW at 380-415 V. Connected to a TPRBC bus coupler, it provides upstream voltage detection plus electrical line and load protection, with power monitoring available via a TPRVM module.
Technical Specifications
| Reference | TPRST025 |
| Brand | Schneider Electric |
| Range | TeSys |
| Product name | TeSys island |
| Device short name | TPRST |
| Product type | Motor starter |
| Motor starter type | Direct on line |
| Poles | 3P (3 NO) |
| Rated operational current (Ie) AC-3 | 25 A at <=440 V |
| Rated operational current (Ie) AC-1 | 30 A at <=440 V |
| Motor power | 11 kW at 380...415 V AC-3 |
| Thermal protection adjustment range | 0.5...25 A, class 5...30 |
| Rated insulation voltage (Ui) | 690 V (IEC) / 600 V (UL, CSA) |
| Rated short-time withstand current (Icw) | 240 A / 10 s |
| Rated making / breaking capacity | 450 A at 440 V |
| Control circuit voltage (Uc) | 24 V DC, supplied by the bus coupler |
| Product compatibility | TPRBC bus coupler, TPRVM voltage interface module |
| Mounting mode | 35 mm DIN rail |
| IP degree of protection | IP20 |
| Ambient operating temperature | -10...50 C without derating |
| Dimensions (H x W x D) | 121 x 45 x 115 mm |
| Net weight | 0.718 kg |
Certifications & Standards
- CCC
- UL
- CSA
- EAC
- EN/IEC 60947-1
- EN/IEC 60947-4-1
- UL 60947-4-1
- CSA C22.2 No 60947-4-1
Selection Notes
The 25 A AC-3 rating covers direct-on-line starting of motors up to 11 kW at 380-415 V, with the thermal overload adjustable from 0.5 to 25 A across trip classes 5 to 30. Operation always requires a TPRBC bus coupler, which supplies the 24 V DC control power and the fieldbus connection - this starter has no standalone control circuit of its own. Unlike the SIL-rated starter in this island range, the TPRST025 has no safe-stop function and no compatibility with a safety interface module, making it the choice for standard motor control duties without a functional-safety requirement. Adding a TPRVM voltage module extends monitoring to active/reactive power, energy and true power factor.