Contactors for Data Center PDU and UPS Systems: Selection Guide
AC-1 and AC-6a contactors for data center PDU and UPS systems: sizing, harmonic derating, coil selection, and endurance guidance for engineers. Shop at Stoklink.
The Schneider Electric LXD1M7 is a TeSys LXD1 replacement contactor coil rated 220 V AC 50/60 Hz, compatible with the LC1D09 through LC1D38 and LC1DT20 through LC1DT40 contactor range. It draws 70 VA inrush and 7-7.5 VA hold-in power, with a coil resistance of 515.4 Ohm and 18 H inductance in the closed-circuit state, and has no built-in suppressor module.
This is a service-replacement coil, not a complete contactor: it fits the LC1D09 to LC1D38 and LC1DT20 to LC1DT40 frame sizes, so confirm the existing contactor's reference falls in that range before ordering. It has no built-in suppressor module, unlike the low-consumption BL-suffix contactor coils, so any external surge-suppression wiring on the original coil circuit should stay in place.
Used to replace a failed or mismatched 220 V AC coil in an existing TeSys LC1D or LC1DT contactor without replacing the full contactor body.
| Range | TeSys |
|---|---|
| Product or Component Type | Contactor coil |
| Device short name | LXD1 |
| Control circuit type | AC 50/60 Hz |
| [Uc] control circuit voltage | 220 V AC 50/60 Hz |
| Average resistance | 515.4 Ohm 68 °F (20 °C) |
| Inductance of closed circuit | 18 H |
| Product Compatibility | CAD, LC1D09...D38, LC1DT20...DT40 |
| Mechanical durability | 15 Mcycles |
| Maximum operating rate | 3600 cyc/h 140 °F (60 °C) |
| Coil technology | Without built-in suppressor module |
|---|---|
| Control circuit voltage limits | Drop-out: 0.3...0.6 Uc at 50/60 Hz (at <140 °F (60 °C)), Operational: 0.8...1.1 Uc at 50 Hz (at <140 °F (60 °C)), Operational: 0.85...1.1 Uc at 60 Hz (at <140 °F (60 °C)) |
| Inrush power in VA | 70 VA 60 Hz cos phi 0.75 (at 68 °F (20 °C)), 70 VA 50 Hz cos phi 0.75 (at 68 °F (20 °C)) |
| Hold-in power consumption in VA | 7.5 VA 60 Hz cos phi 0.3 (at 68 °F (20 °C)), 7 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C)) |
| Heat dissipation | 2…3 W 50/60 Hz |
| Ambient Air Temperature for Operation | 23…140 °F (-5…60 °C) |
|---|---|
| Net Weight | 0.15 lb(US) (0.07 kg) |
| Part number | LXD1M7 |
|---|---|
| Type designation | LXD1 |
| Brand | Schneider Electric |
| Condition | New, factory sealed |
| Source | Schneider Electric and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| EAN | 3389110467895 |
| Warranty (in months) | 18 |
|---|
| Country of origin | ID |
|---|---|
| Shipping weight | 0.07 kg |
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 30 Oct 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated operational voltage of LXD1 is 220 V AC.
The tariff (HS) code on file for LXD1 is 85365080.
The EAN (GTIN) of LXD1 is 3389110467895.
LXD1 ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.
AC-1 and AC-6a contactors for data center PDU and UPS systems: sizing, harmonic derating, coil selection, and endurance guidance for engineers. Shop at Stoklink.
Compare AC3 rating IEC contactors versus NEMA size codes, with cross-reference tables, derating formulas, and selection tips for engineers. Shop at Stoklink.
Master AC3 rating selection with our complete contactor checklist covering load sizing, utilization categories, derating, and coordination. Shop at Stoklink.