Part number
LUCB05B
Model no
LUCB
$86.27 On request Dispatch — · From TürkiyeGet a Quote
TeSys Ultra

Schneider Electric LUCB05B TeSys U Advanced Control Unit 1.25-5 A 24 V AC Motor Starter Module

TeSys U advanced control unit, 1.25-5 A adjustable, Class 10 with diagnostics, 24 V AC coil

Rated current
5 A
Rated operational voltage
24 V AC
EAN
3389110364149
Description

About the LUCB

The Schneider Electric LUCB05B is a TeSys U advanced control unit providing adjustable thermal-magnetic motor protection from 1.25 to 5 A plus diagnostic outputs. Plugged into an advanced LUB120, LUB320, or LUB380 power base, it forms a starter-controller with Class 10 overload tripping, phase-failure sensing, earth-fault detection, a thermal-alarm signal, and a test pushbutton for 3-phase motors up to 1.5 kW at 400 V, controlled from a 24 V AC supply.

Certifications & Standards

  • CE
  • UL
  • CSA
  • CCC
  • EAC
  • IEC 60947-6-2
  • UL 60947-4-1
  • CSA C22.2 No 60947-4-1

Selection Notes

The LUCB05B adds a thermal-overload alarm output and a built-in test pushbutton to the same 1.25-5 A, Class 10 protection as the LUCA05B, letting a PLC or SCADA system see an impending trip before the motor actually stops. Choose it over the plain LUCA05B whenever the panel needs remote overload diagnostics; otherwise the two units are functionally identical in protection terms. Use the LUFDA or LULC module to bring the alarm out locally or remotely.

Specification

Full specification

63 values · Last verified 30 Oct 2026

Main 19

Range TeSys
Range of Product TeSys Ultra
Product name TeSys Ultra
Device short name LUCB
Product or Component Type Advanced control unit
Device Application Motor control, Motor protection
Product Specific Application Basic protection and advanced functions, communication
main function available Earth fault protection, Protection against phase failure and phase imbalance, Manual reset, Protection against overload and short-circuit
Product compatibility Power base LUB12, Power base LUB32, Power base LUB38, Power base LUB120, Power base LUB320, Power base LUB380, Reversing contactor breaker LU2B12B, Reversing contactor breaker LU2B32B
[Ue] rated operational voltage 690 V AC
Network frequency 40...60 Hz
Load type 3-phase motor self-cooled
Utilisation category AC-43, AC-44, AC-41
Motor power kW 1.5 kW 400...440 V AC 50/60 Hz, 2.2 kW 500 V AC 50/60 Hz, 3 kW 690 V AC 50/60 Hz
rated motor current adjustment range 1.25…5 A
Thermal overload class Class 10 40…60 Hz -13…158 °F (-25…70 °C) IEC 60947-6-2, Class 10 40…60 Hz -13…158 °F (-25…70 °C) UL 508
Tripping threshold 14.2 x Ir +/- 20 %
Phase failure sensitivity Yes
[Uc] control circuit voltage 24 V AC

Complementary 15

Control circuit voltage limits 20...26.5 V AC 24 V in operation, 14.5 V AC 24 V drop-out
Typical current consumption 140 mA 24 V AC I maximum while closing with LUB12, 220 mA 24 V AC I maximum while closing with LUB32, 220 mA 24 V AC I maximum while closing with LUB38, 70 mA 24 V AC I rms sealed with LUB12, 90 mA 24 V AC I rms sealed with LUB32, 90 mA 24 V AC I rms sealed with LUB38
Heat dissipation 2 W control circuit with LUB12, 3 W control circuit with LUB32, 3 W control circuit with LUB38
Operating time 35 ms opening with LUB12 control circuit, 35 ms opening with LUB32 control circuit, 35 ms opening with LUB38 control circuit, 70 ms closing with LUB12 control circuit, 70 ms closing with LUB32 control circuit, 70 ms closing with LUB38 control circuit
Reset Manual reset
Standards EN 60947-6-2, IEC 60947-6-2, UL 60947-4-1, with phase barrier, CSA C22.2 No 60947-4-1, with phase barrier
Product Certifications CE, UL, CSA, CCC, EAC, ASEFA, ATEX, Marine
[Ui] rated insulation voltage 690 V IEC 60947-6-2, 600 V UL 60947-4-1, 600 V CSA C22.2 No 60947-4-1
[Uimp] rated impulse withstand voltage 6 kV IEC 60947-6-2
Safe separation of circuit 400 V SELV between the control and auxiliary circuits IEC 60947-1, 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1
Fixing mode Plug-in (front face)
Width 1.8 in (45 mm)
Height 2.6 in (66 mm)
Depth 2.4 in (60 mm)
Compatibility code LUCB

Environment 15

IP degree of protection IP20 front panel and wired terminals IEC 60947-1, IP20 other faces IEC 60947-1, IP40 front panel outside connection zone IEC 60947-1
Protective treatment TH IEC 60068
Ambient air temperature for operation -13…158 °F (-25…70 °C)
Ambient Air Temperature for Storage -40…185 °F (-40…85 °C)
Operating altitude 6561.68 ft (2000 m)
Fire resistance 1760 °F (960 °C) parts supporting live components IEC 60695-2-12, 1202 °F (650 °C) IEC 60695-2-12
Shock resistance 10 gn power poles open IEC 60068-2-27, 15 gn power poles closed IEC 60068-2-27
Vibration resistance 2 gn 5…300 Hz power poles open IEC 60068-2-6, 4 gn 5…300 Hz power poles closed IEC 60068-2-6
Resistance to electrostatic discharge 8 kV 3 in open air IEC 61000-4-2, 8 kV 4 on contact IEC 61000-4-2
Non-dissipating shock wave 1 kV serial mode IEC 60947-6-2, 2 kV common mode IEC 60947-6-2
Resistance to radiated fields 9.1 V/m (10 V/m) 3 IEC 61000-4-3
Resistance to fast transients 2 kV 3 serial link IEC 61000-4-4, 4 kV 4 all circuits except for serial link IEC 61000-4-4
Immunity to radioelectric fields 10 V IEC 61000-4-6
Immunity to microbreaks 3 ms
Immunity to voltage dips 70 % / 500 ms IEC 61000-4-11
Show all 63 specifications ↓ Show less ↑14 more values in Identification, Contractual warranty, Logistics.

Identification 8

Part number LUCB05B
Type designation LUCB
Brand Schneider Electric
Condition New, factory sealed
Source Schneider Electric and its authorised distributors
Warranty Manufacturer warranty
Lifecycle status Active, in production
EAN 3389110364149

Contractual warranty 1

Warranty (in months) 18

Logistics 5

Country of origin FR
Shipping weight 0.113 kg
Ships from Türkiye
Dispatch —
Stock On request

Source: manufacturer data · Last verified: 30 Oct 2026

Documents

Documents for LUCB05B

No documents are on file for this part yet.

Ask us for the datasheet
Certifications

Certifications and standards

  • UL
  • CSA
  • CE
  • CCC
  • EAC
  • Marine
  • EN 60947-6-2
  • IEC 60947-6-2
  • UL 60947-4-1
  • with phase barrier
Quick answers

Questions about the LUCB

What is the rated current of LUCB?

The rated current of LUCB is 5 A.

Which supply voltage is LUCB rated for?

The rated operational voltage of LUCB is 24 V AC.

What is the HS code of LUCB for customs?

The tariff (HS) code on file for LUCB is 853650.

What is the EAN of LUCB?

The EAN (GTIN) of LUCB is 3389110364149.

Where does LUCB ship from, and how fast?

LUCB ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.

Guides

Guides for motor starters

All guides for motor starters
Reviews

Customer reviews

Series

Schneider Electric TeSys Ultra

Brand
Schneider Electric
Series
TeSys Ultra
$86.27 On request
Get a Quote
Quote

Get a Quote

LUCB

Genuine parts

Genuine, factory-sealed parts

Schneider Electric · LUCB05B

Every part on Stoklink is new, unused and made by the manufacturer named on the page.

Condition
New and unused, in the manufacturer's factory-sealed packaging.
Sourced from
Schneider Electric and its authorised distributors.
Warranty
The manufacturer's warranty applies.
If a part is not genuine
We refund the full amount.

Added to cart Could not add to cart

View cart