Part number
LC3D32AF7
Model no
LC3D
$339.37 On request Dispatch — · From TürkiyeGet a Quote

Schneider Electric LC3D32AF7 TeSys Deca Star-Delta Starter 32 A 25 kW 400 V 110 V AC Coil Motor Starter

Schneider Electric TeSys Deca star-delta starter, 32 A AC-3, 25 kW at 400 V delta connection, 110 V AC control circuit.

Rated current
32 A
Rated operational voltage
110 V AC
Motor power
25 kW
EAN
3389110550368
Description

About the LC3D

The Schneider Electric LC3D32AF7 is a pre-assembled TeSys Deca star-delta starter rated 32 A AC-3, delivering 25 kW at 400 V in delta connection from three LC1D contactors. It runs on a 110 V AC control circuit, includes a 1-30 s adjustable time-delay block and a mechanical interlock between the line and delta contactors, and mounts on a 166 mm-wide plate.

Certifications & Standards

  • RINA
  • GL
  • GOST
  • BV
  • DNV
  • CCC
  • CSA
  • LROS
  • UL
  • EN 60947-5-1
  • EN 60947-4-1
  • UL 508
  • CSA C22.2 No 14
  • IEC 60947-4-1
  • IEC 60947-5-1
  • IEC 60335-1

Selection Notes

This pre-wired assembly delivers 25 kW at 400 V in delta connection by sequencing three LC1D contactors through a 1-30 s adjustable time-delay block, which limits inrush current during the star-to-delta transition compared with switching a single contactor direct-on-line. The mechanical interlock keeps the line and delta contactors from closing together even if the control logic fails. Schneider ships this starter without a thermal overload relay — add one sized to the motor's full-load current before commissioning.

Specification

Full specification

68 values · Last verified 30 Oct 2026

Main 24

Range TeSys, TeSys Deca
Product name TeSys Deca
Product or Component Type Star delta starter
Device short name LC3D
Contactor application Motor control
Utilisation category AC-3
Device presentation Pre-wired
Poles description 3 x 3P
power pole contact composition 3 x 3 NO
[Ue] rated operational voltage Power circuit <= 690 V AC 25...400 Hz
[Ie] rated operational current 32 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit
Motor power kW 15 kW 220/230 V AC 50/60 Hz, 25 kW 380/400 V AC 50/60 Hz, 30 kW 415 V AC 50/60 Hz, 30 kW 440 V AC 50/60 Hz
Control circuit type AC 50/60 Hz
[Uc] control circuit voltage 110 V AC 50/60 Hz
Auxiliary contact composition 1 NC KM1 star contactor
[Uimp] rated impulse withstand voltage 6 kV IEC 60947
Overvoltage category III
[Ui] rated insulation voltage Power circuit 690 V IEC 60947-4-1, Power circuit 600 V CSA, Power circuit 600 V UL, Signalling circuit 690 V IEC 60947-1, Signalling circuit 600 V CSA, Signalling circuit 600 V UL
Electrical durability 1.65 Mcycles 32 A AC-3 <= 440 V
safety cover Protective cover
Interlocking type Mechanical
Mounting Support Plate
Standards EN 60947-5-1, EN 60947-4-1, UL 508, CSA C22.2 No 14, IEC 60947-4-1, IEC 60947-5-1, IEC 60335-1
Product Certifications RINA, GL, GOST, BV, DNV, CCC, CSA, LROS (Lloyds register of shipping), UL

Complementary 19

Connections - terminals Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid without cable end, Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid without cable end, Power circuit: screw clamp terminals 1 0.004…0.02 in² (2.5…10 mm²) - cable stiffness: flexible without cable end, Power circuit: screw clamp terminals 2 0.004…0.02 in² (2.5…10 mm²) - cable stiffness: flexible without cable end, Power circuit: screw clamp terminals 1 0.002…0.02 in² (1…10 mm²) - cable stiffness: flexible with cable end, Power circuit: screw clamp terminals 2 0.002…0.009 in² (1.5…6 mm²) - cable stiffness: flexible with cable end, Power circuit: screw clamp terminals 1 0.002…0.02 in² (1.5…10 mm²) - cable stiffness: solid without cable end, Power circuit: screw clamp terminals 2 0.004…0.02 in² (2.5…10 mm²) - cable stiffness: solid without cable end
Tightening torque Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm, Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2, Power circuit 22.1 lbf.in (2.5 N.m) screw clamp terminals flat Ø 6 mm, Power circuit 22.1 lbf.in (2.5 N.m) screw clamp terminals Philips No 2, Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2, Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2
Mechanical durability 15 Mcycles
Maximum operating rate 30 cyc/h 140 °F (60 °C)
Starting time 30 s
Coil technology Without built-in suppressor module
Control circuit voltage limits Drop-out: 0.3...0.6 Uc at 50/60 Hz (at <140 °F (60 °C)), Operational: 0.8...1.1 Uc at 50 Hz (at <140 °F (60 °C)), Operational: 0.85...1.1 Uc at 60 Hz (at <140 °F (60 °C))
Inrush power in VA 70 VA 60 Hz cos phi 0.75 (at 68 °F (20 °C)), 70 VA 50 Hz cos phi 0.75 (at 68 °F (20 °C))
Hold-in power consumption in VA 7.5 VA 60 Hz cos phi 0.3 (at 68 °F (20 °C)), 7 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))
Heat dissipation 2…3 W 50/60 Hz
Auxiliary contacts type Mechanically linked IEC 60947-5-1 3 x 1 NO + 1 NC, Mirror contact IEC 60947-4-1 3 x 1 NC
Signalling circuit frequency 25...400 Hz
Minimum switching current 5 mA for signalling circuit
minimum switching voltage 17 V signalling circuit
Non-overlap time 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
Width 6.5 in (166 mm)
Height 4.9 in (124 mm)
Depth 5.9 in (149 mm)
Net Weight 4.48 lb(US) (2.03 kg)

Environment 11

Insulation resistance > 10 MOhm for signalling circuit
IP degree of protection IP20 front face IEC 60529
Climatic withstand IACS E10, IEC 60947-1 Annex Q category D
Protective treatment TH IEC 60068-2-30
Pollution degree 3
Ambient Air Temperature for Storage -76…176 °F (-60…80 °C)
Ambient air temperature for operation -40…158 °F (-40…70 °C) at Uc
Operating altitude 9842.52 ft (3000 m) without derating
Fire resistance 1562 °F (850 °C) IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness Vibrations contactor open2 Gn, 5...300 Hz, Vibrations contactor closed4 Gn, 5...300 Hz, Shocks contactor closed15 Gn for 11 ms, Shocks contactor open8 Gn for 11 ms
Show all 68 specifications ↓ Show less ↑14 more values in Identification, Contractual warranty, Logistics.

Identification 8

Part number LC3D32AF7
Type designation LC3D
Brand Schneider Electric
Condition New, factory sealed
Source Schneider Electric and its authorised distributors
Warranty Manufacturer warranty
Lifecycle status Active, in production
EAN 3389110550368

Contractual warranty 1

Warranty (in months) 18

Logistics 5

Country of origin FR
Shipping weight 2.03 kg
Ships from Türkiye
Dispatch —
Stock On request

Source: manufacturer data · Last verified: 30 Oct 2026

Documents

Documents for LC3D32AF7

No documents are on file for this part yet.

Ask us for the datasheet
Certifications

Certifications and standards

  • UL
  • CSA
  • CCC
  • EN 60947-5-1
  • EN 60947-4-1
  • UL 508
  • CSA C22.2 No 14
  • IEC 60947-4-1
  • IEC 60947-5-1
  • IEC 60335-1
Quick answers

Questions about the LC3D

What is the rated current of LC3D?

The rated current of LC3D is 32 A.

Which supply voltage is LC3D rated for?

The rated operational voltage of LC3D is 110 V AC.

What motor power is LC3D rated for?

The rated motor power of LC3D is 25 kW.

What is the HS code of LC3D for customs?

The tariff (HS) code on file for LC3D is 853710.

What is the EAN of LC3D?

The EAN (GTIN) of LC3D is 3389110550368.

Where does LC3D ship from, and how fast?

LC3D ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.

Guides

Guides for motor starters

All guides for motor starters
Reviews

Customer reviews

$339.37 On request
Get a Quote
Quote

Get a Quote

LC3D

Genuine parts

Genuine, factory-sealed parts

Schneider Electric · LC3D32AF7

Every part on Stoklink is new, unused and made by the manufacturer named on the page.

Condition
New and unused, in the manufacturer's factory-sealed packaging.
Sourced from
Schneider Electric and its authorised distributors.
Warranty
The manufacturer's warranty applies.
If a part is not genuine
We refund the full amount.

Added to cart Could not add to cart

View cart