$716.45 On request Dispatch —· Worldwide delivery Get a Quote
Manufacturer phase-out

Schneider Electric has announced the end of LC1D150G7

Last orders until 31 Dec 2026. After that date, supply depends on remaining stock. Date announced by Schneider Electric for Türkiye, where we source this part.

Recommended replacement

LC1D150AEHEReplacement LC1D

Schneider Electric Schneider Electric LC1D150AEHE TeSys Deca Advanced Contactor 3P 3NO AC-3 150 A 48-130 V AC/DC Coil Contactor 75 kW · 150 A · 1000 V AC On request $716.45

Schneider Electric LC1D150G7 TeSys Deca LC1D 3P 3NO AC-3 150 A 120 V AC Coil 1NO+1NC Contactor

TeSys Deca 3P contactor, 150 A AC-3 (75 kW at 400 V), up to 1000 V AC, 120 V AC 50/60 Hz coil, 1NO+1NC.

Rated current
150 A
Rated operational voltage
1000 V AC
Motor power
75 kW
Control voltage
120 V
Poles
3P
EAN
3389110527537
Description

About the LC1D

The Schneider Electric LC1D150G7 is a TeSys Deca 3-pole contactor rated 150 A in AC-3 at up to 440 V, which corresponds to 75 kW at 380/400 V. It has three normally open power poles for circuits up to 1000 V AC, a 120 V AC 50/60 Hz coil with a built-in transient suppressor and a 1NO+1NC auxiliary block with a mirror contact. Power connection uses screw connectors with 2 inputs.

Certifications & Standards

  • CE
  • UKCA
  • UL
  • CSA
  • CCC
  • EAC
  • Marine
  • IEC 60947-4-1
  • EN 60947-4-1
  • UL 60947-4-1
  • CSA C22.2 No 14
  • JIS C8201-4-1

Selection Notes

The 120 V AC 50/60 Hz coil suits North American 120 V control circuits and also runs on 50 Hz supplies. The key rating is 150 A AC-3 at up to 440 V (75 kW at 400 V); the 200 A value is the resistive AC-1 rating and should not be used to size a motor feeder. It offers 1400 A breaking capacity at 440 V, and its maximum operating rate of 1200 cycles/h makes it a fit for heavy motors with infrequent starts rather than high-cycle duty. The coil carries a built-in peak-limiting diode suppressor, so no separate surge module is needed for the control circuit.

Specification

Full specification

76 values · Last verified 24 Nov 2026

Main 10

Range TeSys
Range of Product TeSys Deca Advanced
Product or Component Type Contactor
Device short name LC1D
Contactor application Motor control, Resistive load
Utilisation category AC-3, AC-3e, AC-1, AC-4
Poles description 3P
[Ue] rated operational voltage Power circuit <= 1000 V AC 25...400 Hz, Power circuit <= 300 V DC
[Ie] rated operational current 200 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit, 150 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit, 150 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit
[Uc] control circuit voltage 120 V AC 50/60 Hz

Complementary 37

Motor power kW 40 kW at 220/230 V AC 50/60 Hz (AC-3), 75 kW at 380/400 V AC 50/60 Hz (AC-3), 80 kW at 415/440 V AC 50/60 Hz (AC-3), 90 kW at 500 V AC 50/60 Hz (AC-3), 100 kW at 660/690 V AC 50/60 Hz (AC-3), 75 kW at 1000 V AC 50/60 Hz (AC-3), 40 kW at 220/230 V AC 50/60 Hz (AC-3e), 75 kW at 380/400 V AC 50/60 Hz (AC-3e), 80 kW at 415/440 V AC 50/60 Hz (AC-3e), 90 kW at 500 V AC 50/60 Hz (AC-3e), 100 kW at 660/690 V AC 50/60 Hz (AC-3e), 75 kW at 1000 V AC 50/60 Hz (AC-3e), 22 kW at 400 V AC 50/60 Hz (AC-4)
Maximum Horse Power Rating 40 hp at 200/208 V AC 50/60 Hz for 3 phase motors, 50 hp at 230/240 V AC 50/60 Hz for 3 phase motors, 100 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 125 hp at 575/600 V AC 50/60 Hz for 3 phase motors
Compatibility code LC1D
Pole contact composition 3 NO
Protective cover With
[Ith] conventional free air thermal current 200 A (at 140 °F (60 °C)) for power circuit
Irms rated making capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 1660 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity 1400 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 250 A 104 °F (40 °C) - 10 min for power circuit, 580 A 104 °F (40 °C) - 1 min for power circuit, 1200 A 104 °F (40 °C) - 10 s for power circuit, 1400 A 104 °F (40 °C) - 1 s for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit
Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1, 315 A gG at <= 690 V coordination type 1 for power circuit, 250 A gG at <= 690 V coordination type 2 for power circuit
Average impedance 0.6 mOhm - Ith 200 A 50 Hz for power circuit
Power dissipation per pole 24 W AC-1, 13.5 W AC-3, 13.5 W AC-3e
[Ui] rated insulation voltage Power circuit 600 V CSA, Power circuit 600 V UL, Power circuit 1000 V IEC 60947-4-1, Signalling circuit 690 V IEC 60947-1, Signalling circuit 600 V CSA, Signalling circuit 600 V UL
Overvoltage category III
Pollution degree 3
[Uimp] rated impulse withstand voltage 8 kV IEC 60947
Safety reliability level B10d = 684932 cycles contactor with nominal load EN/ISO 13849-1, B10d = 10000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability 8 Mcycles
Electrical durability 0.85 Mcycles 150 A AC-3 <= 440 V, 1 Mcycles 200 A AC-1 <= 440 V, 0.85 Mcycles 150 A AC-3e <= 440 V
Control circuit type AC 50/60 Hz
Coil technology Built-in bidirectional peak limiting diode suppressor
Control circuit voltage limits 0.3...0.5 Uc (-40…158 °F (-40…70 °C)):drop-out AC 50/60 Hz, 0.8...1.15 Uc (-40…131 °F (-40…55 °C)):operational AC 50/60 Hz, 1...1.15 Uc (131…158 °F (55…70 °C)):operational AC 50/60 Hz
Inrush power in VA 280…350 VA 60 Hz cos phi 0.9 (at 68 °F (20 °C)), 280…350 VA 50 Hz cos phi 0.9 (at 68 °F (20 °C))
Hold-in power consumption in VA 2…18 VA 60 Hz cos phi 0.9 (at 68 °F (20 °C)), 2…18 VA 50 Hz cos phi 0.9 (at 68 °F (20 °C))
Heat dissipation 3…4.5 W at 50/60 Hz
Operating time 20...35 ms closing, 40...75 ms opening
Maximum operating rate 1200 cyc/h at 60 °C
Connections - terminals Control circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 1 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 1 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 1 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: solid without cable end, Control circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: solid without cable end, Power circuit: connector 1 0.02…0.2 in² (10…120 mm²) - cable stiffness: flexible without cable end, Power circuit: connector 2 0.02…0.08 in² (10…50 mm²) - cable stiffness: flexible without cable end, Power circuit: connector 1 0.02…0.2 in² (10…120 mm²) - cable stiffness: flexible with cable end, Power circuit: connector 2 0.02…0.08 in² (10…50 mm²) - cable stiffness: flexible with cable end, Power circuit: connector 1 0.02…0.2 in² (10…120 mm²) - cable stiffness: solid without cable end, Power circuit: connector 2 0.02…0.08 in² (10…50 mm²) - cable stiffness: solid without cable end
Tightening torque Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals flat Ø 6 mm, Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals Philips No 2, Power circuit 106.2 lbf.in (12 N.m) connector hexagonal 0.2 in (4 mm), Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals pozidriv No 2
Auxiliary contact composition 1 NO + 1 NC
Auxiliary contacts type Mechanically linked 1 NO + 1 NC IEC 60947-5-1, Mirror contact 1 NC IEC 60947-4-1
Signalling circuit frequency 25...400 Hz
Minimum switching voltage 17 V for signalling circuit
Minimum switching current 5 mA for signalling circuit
Insulation resistance > 10 MOhm for signalling circuit
Non-overlap time 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
Mounting Support Rail, Plate

Environment 14

Standards CSA C22.2 No 14, EN 60947-4-1, IEC 60947-4-1, IEC 60335-1:Clause 30.2, IEC 60335-2-40:Annex JJ, UL 60335-2-40:Annex JJ, UL 60947-4-1, CSA C22.2 No 60947-4-1, JIS C8201-4-1
Product Certifications UL, CCC, CSA, CE, UKCA, Marine, EAC
IP degree of protection IP20 front face IEC 60529
Protective treatment THIEC 60068-2-30
Climatic withstand IACS E10 exposure to damp heat
Permissible ambient air temperature around the device -40…140 °F (-40…60 °C), 140…158 °F (60…70 °C) with derating
Operating altitude 0...9842.52 ft (0...3000 m)
Fire resistance 1562 °F (850 °C) IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness Vibrations contactor open 2 Gn, 5...300 Hz), Vibrations contactor closed 4 Gn, 5...300 Hz), Shocks contactor closed 15 Gn for 11 ms), Shocks contactor open 6 Gn for 11 ms)
Height 6.2 in (158 mm)
Width 4.7 in (120 mm)
Depth 5.4 in (136 mm)
Net Weight 5.5 lb(US) (2.5 kg)
Show all 76 specifications ↓ Show less ↑15 more values in Identification, Contractual warranty, Logistics.

Identification 10

Part number LC1D150G7
Type designation LC1D
Brand Schneider Electric
Condition New, factory sealed
Source Schneider Electric and its authorised distributors
Warranty Manufacturer warranty
Lifecycle status Phase-out announced by the manufacturer
Last order date 31 Dec 2026 · as announced for Türkiye, our sourcing market
Replaced by LC1D150AEHE · recommended by Schneider Electric
EAN 3389110527537

Contractual warranty 1

Warranty (in months) 18

Logistics 4

Country of origin CZ
Shipping weight 2.5 kg
Dispatch —
Stock On request

Source: manufacturer data · Last verified: 24 Nov 2026

Documents

Documents for LC1D150G7 5

Certifications

Certifications and standards

  • UL
  • CSA
  • CE
  • UKCA
  • CCC
  • EAC
  • Marine
  • CSA C22.2 No 14
  • EN 60947-4-1
  • IEC 60947-4-1
  • IEC 60335-1:Clause 30.2
  • IEC 60335-2-40:Annex JJ
  • UL 60335-2-40:Annex JJ
  • UL 60947-4-1
  • CSA C22.2 No 60947-4-1
  • JIS C8201-4-1
Quick answers

Questions about the LC1D

What is the rated current of LC1D?

The rated current of LC1D is 150 A.

Which supply voltage is LC1D rated for?

The rated operational voltage of LC1D is 1000 V AC.

What motor power is LC1D rated for?

The rated motor power of LC1D is 75 kW.

Which control voltage does LC1D need?

The control voltage range of LC1D is 120 V.

What is the HS code of LC1D for customs?

The tariff (HS) code on file for LC1D is 853649.

What is the EAN of LC1D?

The EAN (GTIN) of LC1D is 3389110527537.

How is LC1D delivered, and how fast?

LC1D ships worldwide by express courier, with tracking. Shipping and import duties calculated at checkout · nothing to pay on delivery.

Guides

Guides for contactors

All guides for contactors
Reviews

Customer reviews

Series

Schneider Electric Schneider TeSys Deca

Brand
Schneider Electric
Series
Schneider TeSys Deca
Series page →
Series

Other series in Contactors

$716.45 On request
Get a Quote
Quote

Get a Quote

LC1D

Genuine parts

Genuine, factory-sealed parts

Schneider Electric · LC1D150G7

Every part on Stoklink is new, unused and made by the manufacturer named on the page.

Condition
New and unused, in the manufacturer's factory-sealed packaging.
Sourced from
Schneider Electric and its authorised distributors.
Warranty
The manufacturer's warranty applies.
If a part is not genuine
We refund the full amount.

Added to cart Could not add to cart

View cart