- Part number
- LC1D150G7
- Model no
- LC1D
Schneider Electric has announced the end of LC1D150G7
Last orders until 31 Dec 2026. After that date, supply depends on remaining stock. Date announced by Schneider Electric for Türkiye, where we source this part.
- UL
- CSA
- CE
- UKCA
- CCC
- EAC
- Marine
Schneider Electric LC1D150G7 TeSys Deca LC1D 3P 3NO AC-3 150 A 120 V AC Coil 1NO+1NC Contactor
TeSys Deca 3P contactor, 150 A AC-3 (75 kW at 400 V), up to 1000 V AC, 120 V AC 50/60 Hz coil, 1NO+1NC.
Description
About the LC1D
About the LC1D
The Schneider Electric LC1D150G7 is a TeSys Deca 3-pole contactor rated 150 A in AC-3 at up to 440 V, which corresponds to 75 kW at 380/400 V. It has three normally open power poles for circuits up to 1000 V AC, a 120 V AC 50/60 Hz coil with a built-in transient suppressor and a 1NO+1NC auxiliary block with a mirror contact. Power connection uses screw connectors with 2 inputs.
Certifications & Standards
- CE
- UKCA
- UL
- CSA
- CCC
- EAC
- Marine
- IEC 60947-4-1
- EN 60947-4-1
- UL 60947-4-1
- CSA C22.2 No 14
- JIS C8201-4-1
Selection Notes
The 120 V AC 50/60 Hz coil suits North American 120 V control circuits and also runs on 50 Hz supplies. The key rating is 150 A AC-3 at up to 440 V (75 kW at 400 V); the 200 A value is the resistive AC-1 rating and should not be used to size a motor feeder. It offers 1400 A breaking capacity at 440 V, and its maximum operating rate of 1200 cycles/h makes it a fit for heavy motors with infrequent starts rather than high-cycle duty. The coil carries a built-in peak-limiting diode suppressor, so no separate surge module is needed for the control circuit.
Specification
Full specification
Main 10
| Range | TeSys |
|---|---|
| Range of Product | TeSys Deca Advanced |
| Product or Component Type | Contactor |
| Device short name | LC1D |
| Contactor application | Motor control, Resistive load |
| Utilisation category | AC-3, AC-3e, AC-1, AC-4 |
| Poles description | 3P |
| [Ue] rated operational voltage | Power circuit <= 1000 V AC 25...400 Hz, Power circuit <= 300 V DC |
| [Ie] rated operational current | 200 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit, 150 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit, 150 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit |
| [Uc] control circuit voltage | 120 V AC 50/60 Hz |
Complementary 37
| Motor power kW | 40 kW at 220/230 V AC 50/60 Hz (AC-3), 75 kW at 380/400 V AC 50/60 Hz (AC-3), 80 kW at 415/440 V AC 50/60 Hz (AC-3), 90 kW at 500 V AC 50/60 Hz (AC-3), 100 kW at 660/690 V AC 50/60 Hz (AC-3), 75 kW at 1000 V AC 50/60 Hz (AC-3), 40 kW at 220/230 V AC 50/60 Hz (AC-3e), 75 kW at 380/400 V AC 50/60 Hz (AC-3e), 80 kW at 415/440 V AC 50/60 Hz (AC-3e), 90 kW at 500 V AC 50/60 Hz (AC-3e), 100 kW at 660/690 V AC 50/60 Hz (AC-3e), 75 kW at 1000 V AC 50/60 Hz (AC-3e), 22 kW at 400 V AC 50/60 Hz (AC-4) |
|---|---|
| Maximum Horse Power Rating | 40 hp at 200/208 V AC 50/60 Hz for 3 phase motors, 50 hp at 230/240 V AC 50/60 Hz for 3 phase motors, 100 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 125 hp at 575/600 V AC 50/60 Hz for 3 phase motors |
| Compatibility code | LC1D |
| Pole contact composition | 3 NO |
| Protective cover | With |
| [Ith] conventional free air thermal current | 200 A (at 140 °F (60 °C)) for power circuit |
| Irms rated making capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 1660 A at 440 V for power circuit conforming to IEC 60947 |
| Rated breaking capacity | 1400 A at 440 V for power circuit conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 250 A 104 °F (40 °C) - 10 min for power circuit, 580 A 104 °F (40 °C) - 1 min for power circuit, 1200 A 104 °F (40 °C) - 10 s for power circuit, 1400 A 104 °F (40 °C) - 1 s for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit |
| Associated fuse rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1, 315 A gG at <= 690 V coordination type 1 for power circuit, 250 A gG at <= 690 V coordination type 2 for power circuit |
| Average impedance | 0.6 mOhm - Ith 200 A 50 Hz for power circuit |
| Power dissipation per pole | 24 W AC-1, 13.5 W AC-3, 13.5 W AC-3e |
| [Ui] rated insulation voltage | Power circuit 600 V CSA, Power circuit 600 V UL, Power circuit 1000 V IEC 60947-4-1, Signalling circuit 690 V IEC 60947-1, Signalling circuit 600 V CSA, Signalling circuit 600 V UL |
| Overvoltage category | III |
| Pollution degree | 3 |
| [Uimp] rated impulse withstand voltage | 8 kV IEC 60947 |
| Safety reliability level | B10d = 684932 cycles contactor with nominal load EN/ISO 13849-1, B10d = 10000000 cycles contactor with mechanical load EN/ISO 13849-1 |
| Mechanical durability | 8 Mcycles |
| Electrical durability | 0.85 Mcycles 150 A AC-3 <= 440 V, 1 Mcycles 200 A AC-1 <= 440 V, 0.85 Mcycles 150 A AC-3e <= 440 V |
| Control circuit type | AC 50/60 Hz |
| Coil technology | Built-in bidirectional peak limiting diode suppressor |
| Control circuit voltage limits | 0.3...0.5 Uc (-40…158 °F (-40…70 °C)):drop-out AC 50/60 Hz, 0.8...1.15 Uc (-40…131 °F (-40…55 °C)):operational AC 50/60 Hz, 1...1.15 Uc (131…158 °F (55…70 °C)):operational AC 50/60 Hz |
| Inrush power in VA | 280…350 VA 60 Hz cos phi 0.9 (at 68 °F (20 °C)), 280…350 VA 50 Hz cos phi 0.9 (at 68 °F (20 °C)) |
| Hold-in power consumption in VA | 2…18 VA 60 Hz cos phi 0.9 (at 68 °F (20 °C)), 2…18 VA 50 Hz cos phi 0.9 (at 68 °F (20 °C)) |
| Heat dissipation | 3…4.5 W at 50/60 Hz |
| Operating time | 20...35 ms closing, 40...75 ms opening |
| Maximum operating rate | 1200 cyc/h at 60 °C |
| Connections - terminals | Control circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 1 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 1 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 1 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: solid without cable end, Control circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: solid without cable end, Power circuit: connector 1 0.02…0.2 in² (10…120 mm²) - cable stiffness: flexible without cable end, Power circuit: connector 2 0.02…0.08 in² (10…50 mm²) - cable stiffness: flexible without cable end, Power circuit: connector 1 0.02…0.2 in² (10…120 mm²) - cable stiffness: flexible with cable end, Power circuit: connector 2 0.02…0.08 in² (10…50 mm²) - cable stiffness: flexible with cable end, Power circuit: connector 1 0.02…0.2 in² (10…120 mm²) - cable stiffness: solid without cable end, Power circuit: connector 2 0.02…0.08 in² (10…50 mm²) - cable stiffness: solid without cable end |
| Tightening torque | Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals flat Ø 6 mm, Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals Philips No 2, Power circuit 106.2 lbf.in (12 N.m) connector hexagonal 0.2 in (4 mm), Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals pozidriv No 2 |
| Auxiliary contact composition | 1 NO + 1 NC |
| Auxiliary contacts type | Mechanically linked 1 NO + 1 NC IEC 60947-5-1, Mirror contact 1 NC IEC 60947-4-1 |
| Signalling circuit frequency | 25...400 Hz |
| Minimum switching voltage | 17 V for signalling circuit |
| Minimum switching current | 5 mA for signalling circuit |
| Insulation resistance | > 10 MOhm for signalling circuit |
| Non-overlap time | 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact |
| Mounting Support | Rail, Plate |
Environment 14
| Standards | CSA C22.2 No 14, EN 60947-4-1, IEC 60947-4-1, IEC 60335-1:Clause 30.2, IEC 60335-2-40:Annex JJ, UL 60335-2-40:Annex JJ, UL 60947-4-1, CSA C22.2 No 60947-4-1, JIS C8201-4-1 |
|---|---|
| Product Certifications | UL, CCC, CSA, CE, UKCA, Marine, EAC |
| IP degree of protection | IP20 front face IEC 60529 |
| Protective treatment | THIEC 60068-2-30 |
| Climatic withstand | IACS E10 exposure to damp heat |
| Permissible ambient air temperature around the device | -40…140 °F (-40…60 °C), 140…158 °F (60…70 °C) with derating |
| Operating altitude | 0...9842.52 ft (0...3000 m) |
| Fire resistance | 1562 °F (850 °C) IEC 60695-2-1 |
| Flame retardance | V1 conforming to UL 94 |
| Mechanical robustness | Vibrations contactor open 2 Gn, 5...300 Hz), Vibrations contactor closed 4 Gn, 5...300 Hz), Shocks contactor closed 15 Gn for 11 ms), Shocks contactor open 6 Gn for 11 ms) |
| Height | 6.2 in (158 mm) |
| Width | 4.7 in (120 mm) |
| Depth | 5.4 in (136 mm) |
| Net Weight | 5.5 lb(US) (2.5 kg) |
Show all 76 specifications ↓ Show less ↑15 more values in Identification, Contractual warranty, Logistics.
Identification 10
| Part number | LC1D150G7 |
|---|---|
| Type designation | LC1D |
| Brand | Schneider Electric |
| Condition | New, factory sealed |
| Source | Schneider Electric and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Phase-out announced by the manufacturer |
| Last order date | 31 Dec 2026 · as announced for Türkiye, our sourcing market |
| Replaced by | LC1D150AEHE · recommended by Schneider Electric |
| EAN | 3389110527537 |
Contractual warranty 1
| Warranty (in months) | 18 |
|---|
Logistics 4
| Country of origin | CZ |
|---|---|
| Shipping weight | 2.5 kg |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 24 Nov 2026
Documents
Documents for LC1D150G7 5
-
Datasheet
ProductDownload PDF: Product data sheet LC1D150G7
Product data sheet LC1D150G7
-
Catalogue
ProductDownload PDF: Catalog 0100CT2401-SEC-17
Catalog 0100CT2401-SEC-17
-
Manual
ProductDownload PDF: Instruction sheet 1511301_01A55
Instruction sheet 1511301_01A55
-
Certificate
ProductDownload PDF: Environmental Disclosure ENVPEP0603001EN
Environmental Disclosure ENVPEP0603001EN
-
Drawing
ProductDownload PDF: Technical Drawing LC1D150G7_2DSalesDrawing
Technical Drawing LC1D150G7_2DSalesDrawing
Certifications
Certifications and standards
- UL
- CSA
- CE
- UKCA
- CCC
- EAC
- Marine
- CSA C22.2 No 14
- EN 60947-4-1
- IEC 60947-4-1
- IEC 60335-1:Clause 30.2
- IEC 60335-2-40:Annex JJ
- UL 60335-2-40:Annex JJ
- UL 60947-4-1
- CSA C22.2 No 60947-4-1
- JIS C8201-4-1
Quick answers
Questions about the LC1D
What is the rated current of LC1D?
The rated current of LC1D is 150 A.
Which supply voltage is LC1D rated for?
The rated operational voltage of LC1D is 1000 V AC.
What motor power is LC1D rated for?
The rated motor power of LC1D is 75 kW.
Which control voltage does LC1D need?
The control voltage range of LC1D is 120 V.
What is the HS code of LC1D for customs?
The tariff (HS) code on file for LC1D is 853649.
What is the EAN of LC1D?
The EAN (GTIN) of LC1D is 3389110527537.
How is LC1D delivered, and how fast?
LC1D ships worldwide by express courier, with tracking. Shipping and import duties calculated at checkout · nothing to pay on delivery.
Guides
Guides for contactors
Contactors for Data Center PDU and UPS Systems: Selection Guide
AC-1 and AC-6a contactors for data center PDU and UPS systems: sizing, harmonic derating, coil selection, and endurance guidance for engineers. Shop at Stoklink.
NEMA vs IEC Contactor Standards: Key Differences and Size Comparison
Compare AC3 rating IEC contactors versus NEMA size codes, with cross-reference tables, derating formulas, and selection tips for engineers. Shop at Stoklink.
How to Select the Right Contactor for Your Application: Complete Checklist
Master AC3 rating selection with our complete contactor checklist covering load sizing, utilization categories, derating, and coordination. Shop at Stoklink.
Reviews
Customer reviews
Series
Schneider Electric Schneider TeSys Deca
- Brand
- Schneider Electric
- Series
- Schneider TeSys Deca