The Schneider Electric LA9G3SA is a TeSys Giga switching module kit that replaces the main contacts of a 3-pole LC1G400-500 contactor, rated 500 A AC-3 (700 A AC-1) at up to 440 V. The plug-and-play design lets the contact set be swapped without replacing the whole contactor, extending its service life.
The LA9G3SA matches the 500 A AC-3 rating of the LC1G400-500 frame, the top of the LA9G switching-module family. Smaller frames use the LA9G3QA (225 A AC-3) or LA9G3RA (330 A AC-3) modules instead. Replacing only the switching module after heavy-duty switching service is cheaper than replacing the full contactor body and coil.
| Range | TeSys |
|---|---|
| Device short name | LA9G |
| Product or Component Type | Switch module |
| Quantity per Set | Set of 3 |
| Product Compatibility | LC1G400...500 |
|---|---|
| Accessory / Separate Part Type | Kit |
| Maximum [Ie] rated operational current | 700 A AC-1 <= 440 V 104 °F (40 °C), 500 A AC-3 <= 440 V 104 °F (40 °C) |
| Poles description | 3P |
| Connections - Terminals | Bolted connection |
| Pollution degree | 3 IEC 60947-1 |
|---|---|
| Operating altitude | 9842.52 ft (3000 m) without power derating, 5000 m with derating factor |
| Standards | EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, GB/T 14048.4 |
| Ambient Air Temperature for Operation | -13…140 °F (-25…60 °C) |
| Ambient Air Temperature for Storage | -76…176 °F (-60…80 °C) |
| Part number | LA9G3SA |
|---|---|
| Type designation | LA9G |
| Brand | Schneider Electric |
| Condition | New, factory sealed |
| Source | Schneider Electric and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| EAN | 03606481916754 |
| Warranty (in months) | 18 |
|---|
| Country of origin | CN |
|---|---|
| Shipping weight | 4.601 kg |
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 30 Oct 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated current of LA9G is 500 A.
The tariff (HS) code on file for LA9G is 853690.
The EAN (GTIN) of LA9G is 03606481916754.
LA9G ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.
AC-1 and AC-6a contactors for data center PDU and UPS systems: sizing, harmonic derating, coil selection, and endurance guidance for engineers. Shop at Stoklink.
Compare AC3 rating IEC contactors versus NEMA size codes, with cross-reference tables, derating formulas, and selection tips for engineers. Shop at Stoklink.
Master AC3 rating selection with our complete contactor checklist covering load sizing, utilization categories, derating, and coordination. Shop at Stoklink.