Schneider Electric GZ1E20 Easy TeSys Power 3P 13-18 A 10 kA Motor Protection Circuit Breaker (MPCB)
Schneider Electric GZ1E20 Easy TeSys Power 3P 13-18 A 10 kA Motor Protection Circuit Breaker (MPCB)
Get Quote
- Description
The Schneider Electric GZ1E20 is a 3-pole Easy TeSys Power motor circuit breaker with an adjustable thermal-magnetic trip set at 13-18 A, giving a breaking capacity (Icu) of 10 kA at 400/415 V. It is DIN-rail mounted, operated by a push-button, and conforms to IEC 60947-2 and IEC 60947-4-1 for direct motor protection.
Technical Specifications
| Reference | GZ1E20 |
| Brand | Schneider Electric |
| Range | Easy TeSys Power |
| Device short name | GZ1E |
| Device application | Motor |
| Trip unit technology | Thermal-magnetic |
| Poles | 3P |
| Utilisation category | AC-3 (IEC 60947-2) |
| Thermal protection adjustment range | 13-18 A |
| Magnetic tripping current | 223 A |
| Motor power at 400 V | 7.5 kW |
| Breaking capacity (Icu) | 10 kA (230/240 V: ≥100 kA | 440 V: 6 kA | 500 V: 5 kA | 690 V: 2 kA) |
| Ics rated service breaking capacity (400/415 V) | 50% |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
| [Ui] rated insulation voltage | 690 V AC 50/60 Hz |
| [Uimp] rated impulse withstand voltage | 6 kV |
| Power dissipation | 2.5 W per pole |
| Mounting | DIN rail, by clips or screws |
| Control type | Push-button |
| Connections - terminals | Screw clamp, 1-6 mm² solid / 1-4 mm² flexible with cable end |
| Dimensions (H x W x D) | 89 x 44.5 x 78 mm |
| Net weight | 0.26 kg |
| IP degree of protection | IP20 |
| Ambient air temperature (operation) | -20 to 60°C |
| Operating altitude | 2000 m |
Certifications & Standards
- CE
- CCC
- EAC
- EN/IEC 60947-2
Selection Notes
Set the GZ1E20's thermal dial to the motor's nameplate full-load current within its 13-18 A range so the breaker trips on genuine overload rather than normal starting current. For a lower current band, the GZ1E16 covers 9-14 A; for a higher one, the GZ1E21 covers 17-23 A. Note that the breaking capacity at 400/415 V drops to 10 kA on this current step, well below the ≥100 kA of the smaller GZ1E16 below it in the range, so upstream fault-current coordination should be checked when stepping up to this rating. Where a fixed, non-adjustable trip is preferred instead of the thermal dial, the magnetic-only GZ1LE series in the same frame and footprint is the alternative.