- Home
- All Products
- Schneider Electric BLRCH400A480B44 VarPlus Can HDuty 40 kvar 440 V 50 Hz Power Factor Correction Capacitor Schneider Electric BLRCH400A480B44 VarPlus Can HDuty 40 kvar 440 V 50 Hz Power Factor Correction Capacitor
Schneider Electric BLRCH400A480B44 VarPlus Can HDuty 40 kvar 440 V 50 Hz Power Factor Correction Capacitor
Schneider Electric BLRCH400A480B44 VarPlus Can HDuty 40 kvar 440 V 50 Hz Power Factor Correction Capacitor
Get Quote
- Description
The Schneider Electric BLRCH400A480B44 is a VarPlus Can HDuty power factor correction capacitor rated 40 kvar at 440 V, 50 Hz (48 kvar at 60 Hz). Built with a metallized polypropylene film dielectric and a 1.8× In continuous overcurrent rating for networks with up to 20% harmonic content, it connects through a clamptite terminal in a 116 mm diameter, IP00 enclosure weighing 4.1 kg.
Technical Specifications
| Brand | Schneider Electric |
| Reference | BLRCH400A480B44 |
| Range | PowerLogic |
| Series | VarPlus Can HDuty |
| Product or component type | Heavy duty capacitor |
| Rated reactive power | 40 kvar at 440 V, 50 Hz / 48 kvar at 440 V, 60 Hz |
| Rated voltage | 440 V AC, 50/60 Hz |
| Network harmonic content | ≤ 20% |
| Maximum permissible voltage | 1.1 x Un (8 hours over 24 hours) |
| Continuous overcurrent / inrush current | 1.8 x In continuous / 250 x In inrush |
| Capacitance tolerance | -5% to +10% |
| Losses | Dielectric < 0.2 W/kvar, total < 0.5 W/kvar |
| Voltage test (terminal to terminal) | 2.15 x Un AC for 10 s |
| Connections / terminals | ClampTite terminal |
| Mounting mode | Upright/horizontal, indoor installation |
| Dimensions (diameter x height) | 116 mm x 321 mm |
| Net weight | 4.1 kg |
| IP degree of protection | IP00 |
| Ambient air temperature for operation | -25…+55 °C (temperature class D) |
| Operating altitude | ≤ 2000 m, ≤ 95% relative humidity |
Certifications & Standards
- IEC 60831-1
- IEC 60831-2
Selection Notes
HDuty (heavy duty) construction gives the BLRCH400A480B44 a 1.8× In continuous overcurrent capacity, so it stays within rating on networks where variable-speed drives or rectifiers push harmonic distortion toward the 20% ceiling — a standard-duty capacitor sized only for the fundamental would overheat under the same load. At 440 V the unit delivers 40 kvar on a 50 Hz network or 48 kvar on a 60 Hz network from the same can, useful when the same bank design serves both European and North American sites. Pick this variant to match bus voltage directly rather than relying on a transformer tap; the 116 mm x 321 mm can and clamptite terminal keep the footprint compact for panel-mounted power factor correction banks.