Types of Molded Case Circuit Breakers: MCCB Guide for Engineers
Compare MCCB types including thermal-magnetic, electronic trip, motor protection, current-limiting, and DC-rated units for industrial use. Shop at Stoklink.
ABB Tmax XT7S 1SDA101135R1, 1000A 4-pole fixed MCCB, Ekip Touch Meas.LSI release, 50 kA Icu at 415V AC.
The ABB Tmax XT7S 1SDA101135R1 is a four-pole, fixed XT7 moulded case circuit breaker rated 1000 A, with front terminals and a lever operating mechanism. Performance level S gives it 50 kA Icu at 415 V AC, lower than the H class, and the Ekip Touch Meas.LSI release provides long-time, short-time, instantaneous protection with metering.
Performance level S gives this breaker 50 kA Icu at 415 V AC, lower than the 70 kA of the H class, which suits boards where the prospective fault current does not justify the higher-rated breaker. The Ekip Touch Meas.LSI release still provides full L/S/I protection with integrated metering, and the 20 kA Icw supports selective coordination. Choose the H performance class instead where fault levels are higher, or the 3-pole version where the neutral does not need switching.
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
|---|
| Ambient Air Temperature | Operation -40 ... 125 °C |
|---|
| Product Net Width | 280 mm |
|---|---|
| Product Net Height | 268 mm |
| Product Net Depth / Length | 166 mm |
| Product Net Weight | 12.5 kg |
| Part number | 1SDA101135R1 |
|---|---|
| Type designation | XT7S |
| Brand | ABB |
| Condition | New, factory sealed |
| Source | ABB and its authorised distributors |
| Warranty | Manufacturer warranty |
| EAN | 8056221014380 |
| ETIM class | EC000228 |
| eCl@ss | 27370409 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Circuit Breaker Type to be Associated | Power Distribution |
|---|---|
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Version | F |
| Current Type | AC |
|---|---|
| Electrical Durability | 3000 cycle, 60 cycles per hour |
| Mechanical Durability | 10000 cycle, 60 cycles per hour |
| Number of Poles | 4P |
| Order Multiple | 1 piece |
| Power Loss | at Rated Operating Conditions per Pole 37 W |
| Rated Current (In) | 1000 A |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 85 kA, (230 V AC) 85 kA, (240 V AC) 85 kA, (380 V AC) 50 kA, (415 V AC) 50 kA, (440 V AC) 50 kA, (500 V AC) 45 kA, (525 V AC) 45 kA, (690 V AC) 30 kA |
| Rated Short-time Withstand Current Low Voltage (Icw) | 20 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 85 kA, (230 V AC) 85 kA, (240 V AC) 85 kA, (380 V AC) 50 kA, (415 V AC) 50 kA, (440 V AC) 50 kA, (500 V AC) 45 kA, (525 V AC) 45 kA, (690 V AC) 30 kA |
| Rated Uninterrupted Current (Iu) | 1000 A |
| Release | Ekip Touch Measuring LSI |
| Release Type | EL |
| Short-Circuit Performance Level | S |
| Standards | IEC60947-2 |
| Sub-type | XT7 |
| Terminal Connection Type | Front |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
|---|---|
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Package Level 1 Units | box 1 piece |
|---|---|
| Package Level 1 Width | 360 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 360 mm |
| Package Level 1 Gross Weight | 14 kg |
| Package Level 1 EAN | 8056221014380 |
| Shipping weight | 12.5 kg |
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 02 Oct 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated current of XT7S is 1000 A.
The rated operational voltage of XT7S is 690 V AC.
The tariff (HS) code on file for XT7S is 853620.
The EAN (GTIN) of XT7S is 8056221014380.
XT7S ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.
Compare MCCB types including thermal-magnetic, electronic trip, motor protection, current-limiting, and DC-rated units for industrial use. Shop at Stoklink.
Select the right MCCB with our engineer checklist covering IEC 60947-2, sizing, breaking capacity, trip units, and derating for industry. Shop at Stoklink.
IEC 60947-2 defines MCCB ratings Icu, Ics, Icw, utilization categories A and B, and type tests for low-voltage circuit breakers up to 1000V. Shop...