ABB SACE Emax 2 Air Circuit Breaker: Selection, Application and Maintenance Guide
ABB Emax 2 air circuit breaker selection, sizing, trip units, selectivity, and maintenance guide for 630 to 6300 A LV switchgear engineers. Shop at...
ABB SACE Emax 2 E1.2N 630 Ekip Dip LI 4p F F air circuit breaker, 630 A, 66 kA Icu at 400 V AC, fixed front terminals.
The ABB 1SDA071351R1 is a SACE Emax 2 E1.2N 630 Ekip Dip LI 4p F F air circuit breaker rated for 630 A uninterrupted current (Iu) with a 66 kA ultimate breaking capacity (Icu) at 400 V AC. It is fixed, four-pole, with front terminals and no drawout mechanism.
Without the short-time delay (S) stage, Ekip Dip LI opens instantly on overload (L) or fault (I) rather than riding through a downstream fault, so this breaker is best placed where instantaneous tripping is acceptable rather than as a selectively coordinated main. The fixed F F body avoids the cradle and racking hardware the WMP version needs, cutting the 31 W power loss well below the 1000 A E1.2N siblings — pick it for a permanently mounted 630 A four-pole position with no isolation-by-withdrawal requirement.
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
|---|
| Product Net Width | 280 mm |
|---|---|
| Product Net Height | 296 mm |
| Product Net Depth / Length | 183 mm |
| Product Net Weight | 16 kg |
| Product Main Type | SACE Emax 2 |
|---|---|
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| Part number | 1SDA071351R1 |
|---|---|
| Type designation | E1.2N |
| Brand | ABB |
| Condition | New, factory sealed |
| Source | ABB and its authorised distributors |
| Warranty | Manufacturer warranty |
| EAN | 8015644752019 |
| ETIM class | EC000228 |
| eCl@ss | 27370409 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Connecting Capacity | 400 mm² |
|---|---|
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle, Ue = 500 ... 690 V 8000 cycle, 30 cycles per hour |
| Mechanical Durability | 20000 cycle, 60 cycles per hour |
| Neutral Pole Current ([%Iu]) | 100 % |
| Number of Poles | 4P |
| Power Loss | 31 W |
| Rated Current (In) | 630 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 50 kA, (230 V AC) 50 kA, (380 V AC) 50 kA, (400 V AC) 50 kA, (415 V AC) 50 kA, (440 V AC) 50 kA, (500 V AC) 50 kA, (660 V AC) 50 kA, (690 V AC) 50 kA |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 50 kA, for 3 s 30 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 66 kA, (415 V AC) 66 kA, (440 V AC) 66 kA, (500 V AC) 50 kA, (525 V AC) 50 kA, (690 V AC) 50 kA |
| Rated Uninterrupted Current (Iu) | 630 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Dip LI |
| Release Type | EL |
| Short-Circuit Performance Level | N |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 45 N·m |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
|---|---|
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Package Level 1 Units | box 1 piece |
|---|---|
| Package Level 1 Width | 350 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 18 kg |
| Package Level 1 EAN | 8015644752019 |
| Shipping weight | 16.0 kg |
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 02 Oct 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated current of E1.2N is 630 A.
The rated operational voltage of E1.2N is 690 V AC.
The tariff (HS) code on file for E1.2N is 853620.
The EAN (GTIN) of E1.2N is 8015644752019.
E1.2N ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.
ABB Emax 2 air circuit breaker selection, sizing, trip units, selectivity, and maintenance guide for 630 to 6300 A LV switchgear engineers. Shop at...
Select the correct ABB Emax 2 Ekip trip unit with this guide to LI, LSI, LSIG codes, frame sizing, and measurement classes for switchgear....
Compare ABB Emax 2, Schneider MasterPact MTZ, and Siemens 3WL air circuit breakers by ratings, features, IEC 60947 compliance, and price. Shop at Stoklink.