Description
About the OT63F4N2
About the OT63F4N2
The ABB OT63F4N2 (SKU: 1SCA105365R1001) is a 4-pole low voltage switch disconnector designed for safe isolation of electrical circuits in industrial control panels and distribution systems. Rated at 63A and compliant with IEC 60947-3, UL 508, and CSA C22.2 No.14, the OT63F4N2 supports both base mounting and DIN-rail installation, offering installation flexibility for a wide range of panel configurations. Compact at 70 × 91.5 × 72.5 mm and weighing just 0.31 kg, it is an ideal choice for space-constrained enclosures.
Certifications & Standards
- CE: Conformité Européenne — meets EU safety, health, and environmental protection requirements
- RoHS: Restriction of Hazardous Substances — compliant with EU Directive 2011/65/EU and Amendment 2015/863
- REACH: Registration, Evaluation, Authorisation and Restriction of Chemicals — EU chemical safety compliance
- IEC 60947-3: International standard for switches, disconnectors, switch-disconnectors and fuse-combination units
- IEC 60947: General rules for low-voltage switchgear and controlgear
- IEC/EN 60664: Insulation coordination for equipment within low-voltage systems
- EN 60664: European adoption of IEC 60664 insulation coordination standard
- UL 508: UL standard for industrial control equipment (USA)
- CSA C22.2 No.14: Canadian Standards Association standard for industrial control equipment
- CSA: Canadian Standards Association certification
- cULus: Combined UL certification covering both US (UL) and Canadian (cUL) markets
- ATEX: Compliance with EU directive for equipment used in explosive atmospheres
- VDE: Verband der Elektrotechnik — German electrical engineering certification
- WEEE: Waste Electrical and Electronic Equipment Directive — EU end-of-life product compliance
Applications & Use Cases
- Main or branch circuit isolation in industrial control panels and motor control centers
- Safe maintenance isolation for machinery, HVAC systems, and process equipment
- Distribution boards and sub-distribution panels in commercial and industrial buildings
- Applications requiring ATEX-rated isolation in potentially explosive environments
- DIN-rail mounted panels with space constraints requiring compact 4-pole disconnection
Specification
Full specification
Material Compliance 1
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
|---|
Environmental 2
| Degree of Protection | Front IP20 |
|---|---|
| Pollution Degree | 3 |
Dimensions 4
| Product Net Width | 70 mm |
|---|---|
| Product Net Height | 91.5 mm |
| Product Net Depth / Length | 72.5 mm |
| Product Net Weight | 0.31 kg |
Show all 70 specifications ↓ Show less ↑63 more values in Identification, Technical, Technical UL/CSA, External Classifications and Standards, Logistics.
Identification 12
| Part number | 1SCA105365R1001 |
|---|---|
| Type designation | OT63F4N2 |
| Brand | ABB |
| Condition | New, factory sealed |
| Source | ABB and its authorised distributors |
| Warranty | Manufacturer warranty |
| EAN | 6417019393094 |
| ETIM class | EC000216 |
| eCl@ss | 27371403 |
| Minimum Order Quantity | 10 piece |
| Customs Tariff Number | 85365080 |
| Country of Origin | Finland |
Technical 32
| Cable Cross-Section | Cu 1.5 ... 35 mm² |
|---|---|
| Color | Grey |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1x Cu 1.5…4 mm², Solid 1x Cu 1.5…6 mm², Flexible 1x Cu 1.5…35 mm², Stranded 1x Cu 1.5…35 mm² |
| Conventional Free-air Thermal Current (Ith) | Θ = 40 °C 63 A |
| Conventional Thermal Current (Ithe) | Fully Enclosed 63 A |
| Distance Between Phases | Standard |
| Fourth Pole Position | Right Side |
| Fourth Pole Type | Switched - Simultaneous Function |
| Handle Type | Knob |
| Mechanical Durability | 20000 |
| Mounting Type | Base mounting |
| Number of Poles | 4P |
| Operating Mode | Front |
| Position of Line Terminals | Top In - Bottom Out, Bottom In - Top Out |
| Power Loss | at Rated Operating Conditions per Pole 2.8 W |
| Rated Conditional Short-Circuit Current (Inc) | (100 A fuse, ≤415 V) 50 kA, (100 A fuse, 500 V) 100 kA, (80 A fuse, 690 V) 50 kA |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | acc. to IEC/EN 60664-1 750 V |
| Rated Operational Current AC-21A (Ie) | (380 ... 415 V) 63 A, (500 V) 63 A, (690 V) 63 A |
| Rated Operational Current AC-22A (Ie) | (380 ... 415 V) 63 A, (500 V) 63 A, (690 V) 63 A |
| Rated Operational Current AC-23A (Ie) | (380 ... 415 V) 63 A, (500 V) 45 A, (690 V) 20 A |
| Rated Operational Power AC-23A (Pe) | (220 ... 240 V) 11 kW, (400 ... 415 V) 22 kW, (500 V) 22 kW, (690 V) 15 kW |
| Rated Operational Voltage | Main Circuit 750 V |
| Rated Short-Circuit Making Capacity (Icm) | (690 V) 2.1 kA |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 1.5 kA |
| Recommended Screw Driver | Main Circuit Pozidriv 2 |
| Special Functions | No |
| Standards | IEC 60947-3 / UL 508 / CSA C22.2 No. 14 |
| Switches Operating Mechanism | Mechanism on Top of the Switch |
| Terminal Type | Screw Terminals |
| Tightening Torque | acc. IEC 60947-1 2 N·m |
| Wire Stripping Length | Main Circuit 10-12 mm |
Technical UL/CSA 4
| Maximum Operating Voltage UL/CSA | 600 V |
|---|---|
| Ampere Rating | 60 A |
| Horsepower Rating UL/CSA | (110 ... 120 V AC) Single Phase 2 Hp, (240 V AC) Single Phase 7.5 Hp, (440 ... 480 V AC) Single Phase 15 Hp, (550 ... 600 V AC) Single Phase 15 Hp, (220 ... 240 V AC) Three Phase 15 Hp, (440 ... 480 V AC) Three Phase 30 Hp, (550 ... 600 V AC) Three Phase 30 Hp |
| Tightening Torque UL/CSA | 18 in·lb |
External Classifications and Standards 5
| ETIM 10 | EC000216 - Switch disconnector (AC) |
|---|---|
| UNSPSC | 39122233 |
| eClass | V11.1 : 27371403 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| E-Number (Sweden) | 3171070 |
Logistics 10
| Package Level 1 Units | box 1 piece |
|---|---|
| Package Level 1 Width | 84 mm |
| Package Level 1 Depth / Length | 103 mm |
| Package Level 1 Height | 82 mm |
| Package Level 1 Gross Weight | 0.34 kg |
| Package Level 1 EAN | 6417019393094 |
| Shipping weight | 0.34 kg |
| Ships from | Türkiye |
| Dispatch | 16 Nov |
| Stock | In stock |
Source: manufacturer data · Last verified: 30 Oct 2026
Documents
Documents for 1SCA105365R1001
No documents are on file for this part yet.
Ask us for the datasheet
Certifications
Certifications and standards
- CE
- CSA
- RoHS
- ATEX
- VDE
- IEC 60947-3 / UL 508 / CSA C22.2 No. 14
Quick answers
Questions about the OT63F4N2
What is the HS code of OT63F4N2 for customs?
The tariff (HS) code on file for OT63F4N2 is 85365080.
What is the EAN of OT63F4N2?
The EAN (GTIN) of OT63F4N2 is 6417019393094.
Where does OT63F4N2 ship from, and how fast?
OT63F4N2 ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival. Stock items are dispatched within 1–2 business days.